CVE-2026-12927

Out‑of‑Bounds Write in IGSS Definition Leading to Possible Arbitrary Code Execution

CWE-787 Out-of-bounds write vulnerability exists that could cause loss of data or potentially risk arbitrary code execution when a malicious CGF file is imported to IGSS Definition.

CVSS 4.0 · 8.4 High EPSS < 1% KEV · Not listed
CVE-2026-9650

Unauthorized access via exposed firmware credentials in Schneider Electric remote terminals

CWE-522 Insufficiently Protected Credentials vulnerability that could cause unauthorized access and exposure of sensitive information when unauthenticated attacker accesses credentials stored within firmware or system files. With this credential an attacker could subsequently compromise the device if they have physical access to the device.

CVSS 4.0 · 8.7 High EPSS < 1% KEV · Not listed
CVE-2026-9651

Permission Assignment Flaw Exposes Password Hashes in Schneider Electric Remote Terminals

CWE-732 Incorrect Permission Assignment for Critical Resource vulnerability that could cause unauthorized disclosure of password hashes and potential account compromise when an attacker with privileged local access reads improperly protected system files.

CVSS 4.0 · 6.7 Medium EPSS < 1% KEV · Not listed
CVE-2014-5398

Schneider Electric Wonderware Input Validation

Schneider Electric Wonderware Information Server (WIS) Portal 4.0 SP1 through 5.5 allows remote attackers to read arbitrary files or cause a denial of service via an XML external entity declaration in conjunction with an entity reference, related to an XML External Entity (XXE) issue.

CVSS 2.0 · 2.1 Low EPSS < 1% KEV · Not listed
CVE-2024-5681

CWE-20: Improper Input Validation vulnerability exists that could cause local denial-of-service, privilege escalation, and potentially kernel execution when a malicious actor with local user access crafts a script/program using an IOCTL call in the Foxboro.sys driver.

CVE-2014-9188

Schneider Electric ProClima Command Injection

Buffer overflow in an ActiveX control in MDraw30.ocx in Schneider Electric ProClima before 6.1.7 allows remote attackers to execute arbitrary code via unspecified vectors, a different vulnerability than CVE-2014-8513 and CVE-2014-8514. NOTE: this may be clarified later based on details provided by researchers.

CVSS 2.0 · 10 Critical EPSS 6.3% KEV · Not listed
Products
CVE-2014-8514

Buffer overflow in an ActiveX control in MDraw30.ocx in Schneider Electric ProClima before 6.1.7 allows remote attackers to execute arbitrary code via unspecified vectors, a different vulnerability than CVE-2014-8513 and CVE-2014-9188. NOTE: this may be clarified later based on details provided by researchers.

CVSS 2.0 · 7.5 High EPSS 4.0% KEV · Not listed
Products
CVE-2014-8512

Buffer overflow in an ActiveX control in Atx45.ocx in Schneider Electric ProClima before 6.1.7 allows remote attackers to execute arbitrary code via unspecified vectors, a different vulnerability than CVE-2014-8511. NOTE: this may be clarified later based on details provided by researchers.

CVSS 2.0 · 7.5 High EPSS 3.9% KEV · Not listed
Products
CVE-2014-8513

Buffer overflow in an ActiveX control in MDraw30.ocx in Schneider Electric ProClima before 6.1.7 allows remote attackers to execute arbitrary code via unspecified vectors, a different vulnerability than CVE-2014-8514 and CVE-2014-9188. NOTE: this may be clarified later based on details provided by researchers.

CVSS 2.0 · 7.5 High EPSS 2.9% KEV · Not listed
Products