{"affected": [{"affectedData": [{"defaultStatus": "unaffected", "product": "EasyLogic T150 (formerly Saitel DR) Remote Terminal Unit & Controller", "vendor": "Schneider Electric", "versions": [{"status": "affected", "version": "Version 11.06.31 and prior"}]}, {"defaultStatus": "unaffected", "product": "Saitel DP Remote Terminal Unit & Controller", "vendor": "Schneider Electric", "versions": [{"status": "affected", "version": "Version 11.06.37 and prior"}]}], "source": "cybersecurity@se.com"}], "configurations": [{"nodes": [{"cpeMatch": [{"criteria": "cpe:2.3:o:schneider-electric:easylogic_t150_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "6D498A9B-1593-41C1-BB95-F7815F01087D", "versionEndExcluding": "11.06.32", "vulnerable": true}], "negate": false, "operator": "OR"}, {"cpeMatch": [{"criteria": "cpe:2.3:h:schneider-electric:easylogic_t150:-:*:*:*:*:*:*:*", "matchCriteriaId": "E3B30463-195D-4D26-BC9E-9BA0D9BBB862", "vulnerable": false}], "negate": false, "operator": "OR"}], "operator": "AND"}, {"nodes": [{"cpeMatch": [{"criteria": "cpe:2.3:o:schneider-electric:saitel_dp_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "71B582C0-A3F2-4E6F-B2CE-E77ACB81F59F", "versionEndExcluding": "11.06.38", "vulnerable": true}], "negate": false, "operator": "OR"}, {"cpeMatch": [{"criteria": "cpe:2.3:h:schneider-electric:saitel_dp:-:*:*:*:*:*:*:*", "matchCriteriaId": "E6D73382-1957-4CC7-953F-D57C005D63B0", "vulnerable": false}], "negate": false, "operator": "OR"}], "operator": "AND"}], "cveTags": [], "descriptions": [{"lang": "en", "value": "CWE-732 Incorrect Permission Assignment for Critical Resource vulnerability that could cause unauthorized disclosure of password hashes and potential account compromise when an attacker with privileged local access reads improperly protected system files."}], "id": "CVE-2026-9651", "lastModified": "2026-07-14T16:00:32.253", "metrics": {"cvssMetricV31": [{"cvssData": {"attackComplexity": "LOW", "attackVector": "LOCAL", "availabilityImpact": "NONE", "baseScore": 4.4, "baseSeverity": "MEDIUM", "confidentialityImpact": "HIGH", "integrityImpact": "NONE", "privilegesRequired": "HIGH", "scope": "UNCHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.1/AV:L/AC:L/PR:H/UI:N/S:U/C:H/I:N/A:N", "version": "3.1"}, "exploitabilityScore": 0.8, "impactScore": 3.6, "source": "nvd@nist.gov", "type": "Primary"}], "cvssMetricV40": [{"cvssData": {"Automatable": "NOT_DEFINED", "Recovery": "NOT_DEFINED", "Safety": "NOT_DEFINED", "attackComplexity": "LOW", "attackRequirements": "NONE", "attackVector": "LOCAL", "availabilityRequirement": "NOT_DEFINED", "baseScore": 6.7, "baseSeverity": "MEDIUM", "confidentialityRequirement": "NOT_DEFINED", "exploitMaturity": "NOT_DEFINED", "integrityRequirement": "NOT_DEFINED", "modifiedAttackComplexity": "NOT_DEFINED", "modifiedAttackRequirements": "NOT_DEFINED", "modifiedAttackVector": "NOT_DEFINED", "modifiedPrivilegesRequired": "NOT_DEFINED", "modifiedSubAvailabilityImpact": "NOT_DEFINED", "modifiedSubConfidentialityImpact": "NOT_DEFINED", "modifiedSubIntegrityImpact": "NOT_DEFINED", "modifiedUserInteraction": "NOT_DEFINED", "modifiedVulnAvailabilityImpact": "NOT_DEFINED", "modifiedVulnConfidentialityImpact": "NOT_DEFINED", "modifiedVulnIntegrityImpact": "NOT_DEFINED", "privilegesRequired": "HIGH", "providerUrgency": "NOT_DEFINED", "subAvailabilityImpact": "NONE", "subConfidentialityImpact": "NONE", "subIntegrityImpact": "NONE", "userInteraction": "NONE", "valueDensity": "NOT_DEFINED", "vectorString": "CVSS:4.0/AV:L/AC:L/AT:N/PR:H/UI:N/VC:H/VI:N/VA:N/SC:N/SI:N/SA:N/E:X/CR:X/IR:X/AR:X/MAV:X/MAC:X/MAT:X/MPR:X/MUI:X/MVC:X/MVI:X/MVA:X/MSC:X/MSI:X/MSA:X/S:X/AU:X/R:X/V:X/RE:X/U:X", "version": "4.0", "vulnAvailabilityImpact": "NONE", "vulnConfidentialityImpact": "HIGH", "vulnIntegrityImpact": "NONE", "vulnerabilityResponseEffort": "NOT_DEFINED"}, "source": "cybersecurity@se.com", "type": "Secondary"}], "ssvcV203": [{"source": "134c704f-9b21-4f2e-91b3-4a467353bcc0", "ssvcData": {"id": "CVE-2026-9651", "options": [{"exploitation": "none"}, {"automatable": "no"}, {"technicalImpact": "partial"}], "role": "CISA Coordinator", "timestamp": "2026-06-25T15:49:29.524994Z", "version": "2.0.3"}}]}, "published": "2026-06-25T16:16:43.990", "references": [{"source": "cybersecurity@se.com", "tags": ["Vendor Advisory"], "url": "https://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2026-160-02&p_enDocType=Security+and+Safety+Notice&p_File_Name=SEVD-2026-160-02.pdf"}], "sourceIdentifier": "cybersecurity@se.com", "vulnStatus": "Analyzed", "weaknesses": [{"description": [{"lang": "en", "value": "CWE-732"}], "source": "cybersecurity@se.com", "type": "Secondary"}]}