CVE-2018-10626

Medtronic MyCareLink 24950 Patient Monitor Insufficient Verification of Data Authenticity

Medtronic MyCareLink Patient Monitor’s update service does not sufficiently verify the authenticity of the data uploaded. An attacker who obtains per-product credentials from the monitor and paired implantable cardiac device information can potentially upload invalid data to the Medtronic CareLink network.

CVSS 3.1 · 4.4 Medium EPSS < 1% KEV · Not listed
Vendors
CVE-2025-4397

Medtronic MyCareLink Patient Monitor Data Encryption Weakness

Medtronic MyCareLink Patient Monitor uses per-product credentials that are stored in a recoverable format. An attacker can use these credentials to modify encrypted drive data.

CVSS 3.1 · 6.8 Medium EPSS < 1% KEV · Not listed
Vendors
CVE-2022-32537

Medtronic MiniMed 600 Series Pump System Communication Issue

A vulnerability exists which could allow an unauthorized user to learn aspects of the communication protocol used to pair system components while the pump is being paired with other system components. Exploitation requires nearby wireless signal proximity with the patient and the device; advanced technical knowledge is required for exploitation. Please refer to the Medtronic Product Security Bulletin for guidance

CVSS 3.1 · 4.8 Medium EPSS < 1% KEV · Not listed
Vendors
CVE-2025-12994

Medtronic CareLink Network allows an unauthenticated remote attacker to initiate a request for security questions to an API endpoint that could be used to determine a valid user account. This issue affects CareLink Network: before December 4, 2025.

CVSS 3.1 · 5.3 Medium EPSS < 1% KEV · Not listed
Vendors
Products
CVE-2025-12995

Medtronic CareLink Network allows an unauthenticated remote attacker to perform a brute force attack on an API endpoint that could be used to determine a valid password under certain circumstances. This issue affects CareLink Network: before December 4, 2025.

CVSS 3.1 · 8.1 High EPSS < 1% KEV · Not listed
Vendors
Products
CVE-2025-12996

Medtronic CareLink Network allows a local attacker with access to log files on an internal API server to view plaintext passwords from errors logged under certain circumstances. This issue affects CareLink Network: before December 4, 2025.

CVSS 3.1 · 4.1 Medium EPSS < 1% KEV · Not listed
Vendors
Products
CVE-2025-12997

Insecure Direct Object Reference vulnerability in Medtronic CareLink Network which allows an authenticated attacker with access to specific device and user information to submit web requests to an API endpoint that would expose sensitive user information. This issue affects CareLink Network: before December 4, 2025.

CVSS 3.1 · 2.2 Low EPSS < 1% KEV · Not listed
Vendors
Products
CVE-2018-10631

Medtronic N'Vision Clinician Programmer Protection Mechanism Failure

The 8840 Clinician Programmer executes the application program from the 8870 Application Card. An attacker with physical access to an 8870 Application Card and sufficient technical capability can modify the contents of this card, including the binary executables. If modified to bypass protection mechanisms, this malicious code will be run when the card is inserted into an 8840 Clinician Programmer.

CVSS 3.1 · 6.3 Medium EPSS < 1% KEV · Not listed
CVE-2018-8849

Medtronic N'Vision Clinician Programmer Missing Encryption of Sensitive Data

Medtronic N'Vision Clinician Programmer 8840 N'Vision Clinician Programme and 8870 N'Vision removable Application Card do not encrypt PII and PHI while at rest.

CVSS 3.1 · 4.6 Medium EPSS < 1% KEV · Not listed
Vendors
CVE-2020-27252

Medtronic MyCareLink Smart Time-of-check Time-of-use Race Condition

Medtronic MyCareLink Smart 25000 is vulnerable to a race condition in the MCL Smart Patient Reader software update system, which allows unsigned firmware to be uploaded and executed on the Patient Reader. If exploited, an attacker could remotely execute code on the MCL Smart Patient Reader device, leading to control of the device.

CVSS 3.1 · 8.8 High EPSS 3.8% KEV · Not listed
Vendors
CVE-2020-25187

Medtronic MyCareLink Smart Heap-based Buffer Overflow

Medtronic MyCareLink Smart 25000 is  vulnerable when an authenticated attacker runs a debug command, which can be sent to the patient reader and cause a heap overflow event within the MCL Smart Patient Reader software stack. The heap overflow could allow an attacker to remotely execute code on the MCL Smart Patient Reader, potentially leading to control of the device

CVSS 3.1 · 8.8 High EPSS 3.9% KEV · Not listed
Vendors
CVE-2020-25183

Medtronic MyCareLink Smart Improper Authentication

Medtronic MyCareLink Smart 25000 contains an authentication protocol vulnerability where the method used to authenticate between the MCL Smart Patient Reader and the Medtronic MyCareLink Smart mobile app is vulnerable to bypass. This vulnerability enables an attacker to use another mobile device or malicious application on the patient’s smartphone to authenticate to the patient’s Medtronic Smart Reader, fooling the device into believing it is communicating with the original Medtronic smart phone application when executed within range of Bluetooth communication.

CVSS 3.1 · 8 High EPSS < 1% KEV · Not listed
Vendors
CVE-2019-6540

Medtronic Conexus Radio Frequency Telemetry Protocol Cleartext Transmission of Sensitive Information

The Conexus telemetry protocol utilized within Medtronic MyCareLink Monitor versions 24950 and 24952, CareLink Monitor version 2490C, CareLink 2090 Programmer, Amplia CRT-D, Claria CRT-D, Compia CRT-D, Concerto CRT-D, Concerto II CRT-D, Consulta CRT-D, Evera ICD, Maximo II CRT-D and ICD, Mirro ICD, Nayamed ND ICD, Primo ICD, Protecta ICD and CRT-D, Secura ICD, Virtuoso ICD, Virtuoso II ICD, Visia AF ICD, and Viva CRT-D does not implement encryption. An attacker with adjacent short-range access to a target product can listen to communications, including the transmission of sensitive data.

CVSS 3.1 · 6.5 Medium EPSS < 1% KEV · Not listed
Vendors
CVE-2019-6538

Medtronic Conexus Radio Frequency Telemetry Protocol Improper Access Control

The Conexus telemetry protocol utilized within Medtronic MyCareLink Monitor versions 24950 and 24952, CareLink Monitor version 2490C, CareLink 2090 Programmer, Amplia CRT-D, Claria CRT-D, Compia CRT-D, Concerto CRT-D, Concerto II CRT-D, Consulta CRT-D, Evera ICD, Maximo II CRT-D and ICD, Mirro ICD, Nayamed ND ICD, Primo ICD, Protecta ICD and CRT-D, Secura ICD, Virtuoso ICD, Virtuoso II ICD, Visia AF ICD, and Viva CRT-D does not implement authentication or authorization. An attacker with adjacent short-range access to an affected product, in situations where the product’s radio is turned on, can inject, replay, modify, and/or intercept data within the telemetry communication. This communication protocol provides the ability to read and write memory values to affected implanted cardiac devices; therefore, an attacker could exploit this communication protocol to change memory in the implanted cardiac device.

CVSS 3.1 · 9.3 Critical EPSS < 1% KEV · Not listed
Vendors
CVE-2019-13543

Medtronic Valleylab FT10 and FX8 Use of Hard-coded Credentials

Medtronic Valleylab Exchange Client version 3.4 and below, Valleylab FT10 Energy Platform (VLFT10GEN) software version 4.0.0 and below, and Valleylab FX8 Energy Platform (VLFX8GEN) software version 1.1.0 and below use multiple sets of hard-coded credentials. If discovered, they can be used to read files on the device.

CVSS 3.1 · 5.8 Medium EPSS 2.0% KEV · Not listed
Vendors
CVE-2019-13539

Medtronic Valleylab FT10 and FX8 Reversible One-way Hash

Medtronic Valleylab Exchange Client version 3.4 and below, Valleylab FT10 Energy Platform (VLFT10GEN) software version 4.0.0 and below, and Valleylab FX8 Energy Platform (VLFX8GEN) software version 1.1.0 and below use the descrypt algorithm for OS password hashing. While interactive, network-based logons are disabled, and attackers can use the other vulnerabilities within this report to obtain local shell access and access these hashes.

CVSS 3.1 · 7 High EPSS < 1% KEV · Not listed
Vendors
CVE-2019-13535

Medtronic Valleylab FT10 and LS10 Protection Mechanism Failure

In Medtronic Valleylab FT10 Energy Platform (VLFT10GEN) version 2.1.0 and lower and version 2.0.3 and lower, and Valleylab LS10 Energy Platform (VLLS10GEN—not available in the United States) version 1.20.2 and lower, the RFID security mechanism does not apply read protection, allowing for full read access of the RFID security mechanism data.

CVSS 3.1 · 4.6 Medium EPSS < 1% KEV · Not listed
Vendors
CVE-2019-13531

Medtronic Valleylab FT10 and LS10 Improper Authentication

In Medtronic Valleylab FT10 Energy Platform (VLFT10GEN) version 2.1.0 and lower and version 2.0.3 and lower, and Valleylab LS10 Energy Platform (VLLS10GEN—not available in the United States) version 1.20.2 and lower, the RFID security mechanism used for authentication between the FT10/LS10 Energy Platform and instruments can be bypassed, allowing for inauthentic instruments to connect to the generator.

CVSS 3.1 · 4.8 Medium EPSS < 1% KEV · Not listed