Westermo WeOS 5.x starting from 5.24 allows OS command injection via a media definition.
Search vulnerabilities
An issue was discovered in Westermo WeOS 5 (5.24 through 5.24.4). A threat actor potentially can gain unauthorized access to sensitive information via system logging information (syslog verbose logging that includes credentials).
Westermo WeOS 5 through 5.23.0 allows a reboot via a malformed ESP packet.
Westermo L210-F2G Lynx Cleartext Transmission of Sensitive Information
Plain text credentials and session ID can be captured with a network sniffer.
Westermo L210-F2G Lynx Improper Control of Interaction Frequency
An attacker may be able to cause a denial-of-service condition by sending many SSH packets repeatedly.
Westermo L210-F2G Lynx Improper Control of Interaction Frequency
An attacker may be able to cause a denial-of-service condition by sending many packets repeatedly.
Westermo Lynx Permissive Cross-domain Policy with Untrusted Domains
A potential attacker with access to the Westermo Lynx device would be able to execute malicious code that could affect the correct functioning of the device.
A Use of Hard-Coded Credentials issue was discovered in MRD-305-DIN versions older than 1.7.5.0, and MRD-315, MRD-355, MRD-455 versions older than 1.7.5.0. The device utilizes hard-coded credentials, which could allow for unauthorized local low-privileged access to the device.
A Cross-Site Request Forgery (CSRF) issue was discovered in Westermo MRD-305-DIN versions older than 1.7.5.0, and MRD-315, MRD-355, MRD-455 versions older than 1.7.5.0. The application does not verify whether a request was intentionally provided by the user, making it possible for an attacker to trick a user into making a malicious request to the server.
A Use of Hard-Coded Cryptographic Key issue was discovered in MRD-305-DIN versions older than 1.7.5.0, and MRD-315, MRD-355, MRD-455 versions older than 1.7.5.0. The device utilizes hard-coded private cryptographic keys that may allow an attacker to decrypt traffic from any other source.
Westermo WeOS before 4.19.0 uses the same SSL private key across different customers' installations, which makes it easier for man-in-the-middle attackers to defeat cryptographic protection mechanisms by leveraging knowledge of a key.
Westermo Lynx Code Injection
A potential attacker with access to the Westermo Lynx device may be able to execute malicious code that could affect the correct functioning of the device.
Westermo Lynx Cross-site Scripting
An attacker with access to the web application with vulnerable software could introduce arbitrary JavaScript by injecting a cross-site scripting payload into the "dns.0.server" parameter.
Westermo Lynx Cross-site Scripting
An attacker with access to the web application that has the vulnerable software could introduce arbitrary JavaScript by injecting a cross-site scripting payload into the "autorefresh" parameter.
Westermo Lynx Cross-site Scripting
An attacker with access to the vulnerable software could introduce arbitrary JavaScript by injecting a cross-site scripting payload into the "username" parameter in the SNMP configuration.
Westermo Lynx Cleartext Transmission of Sensitive Information
An attacker with access to the network where the affected devices are located could maliciously actions to obtain, via a sniffer, sensitive information exchanged via TCP communications.
Westermo Lynx
An attacker with access to the Westermo Lynx web application that has the vulnerable software could introduce arbitrary JavaScript by injecting a cross-site scripting payload into the "forward.0.domain" parameter.
Westermo Lynx 206-F2G Cross-Site Request Forgery
The cross-site request forgery token in the request may be predictable or easily guessable allowing attackers to craft a malicious request, which could be triggered by a victim unknowingly. In a successful CSRF attack, the attacker could lead the victim user to carry out an action unintentionally.
Westermo MRD-315 1.7.3 and 1.7.4 devices have an information disclosure vulnerability that allows an authenticated remote attacker to retrieve the source code of different functions of the web application via requests that lack certain mandatory parameters. This affects ifaces-diag.asp, system.asp, backup.asp, sys-power.asp, ifaces-wls.asp, ifaces-wls-pkt.asp, and ifaces-wls-pkt-adv.asp.
Pepperl+Fuchs improper authorization affects multiple Comtrol RocketLinx products
Improper Authorization vulnerability of Pepperl+Fuchs P+F Comtrol RocketLinx ES7510-XT, ES8509-XT, ES8510-XT, ES9528-XTv2, ES7506, ES7510, ES7528, ES8508, ES8508F, ES8510, ES8510-XTE, ES9528/ES9528-XT (all versions) and ICRL-M-8RJ45/4SFP-G-DIN, ICRL-M-16RJ45/4CP-G-DIN FW 1.2.3 and below has an active TFTP-Service.