Export limit exceeded: 10244 CVEs match your query. Please refine your search to export 10,000 CVEs or fewer.

Search vulnerabilities

Results 17

Export CSV
CVE-2026-50043

OS Command Injection via Improper Input Neutralization in Seiko SkyBridge Devices

Improper neutralization of special elements used in an OS command ('OS Command Injection') issue exists in SkyBridge MB-A100/MB-A110. If this vulnerability is exploited, an arbitrary OS command may be executed by an attacker who can log in to the product with an administrative privilege.

CVSS 4.0 · 8.6 High EPSS 1.7% KEV · Not listed
Vendors
CVE-2025-54857

Improper neutralization of special elements used in an OS command ('OS Command Injection') issue exists in SkyBridge BASIC MB-A130 Ver.1.5.8 and earlier. If exploited, a remote unauthenticated attacker may execute arbitrary OS commands with root privileges.

CVSS 4.0 · 9.3 Critical EPSS 2.6% KEV · Not listed
Vendors
CVE-2024-32850

Improper neutralization of special elements used in a command ('Command Injection') exists in SkyBridge MB-A100/MB-A110 firmware Ver. 4.2.2 and earlier and SkyBridge BASIC MB-A130 firmware Ver. 1.5.5 and earlier. If the remote monitoring and control function is enabled on the product, an attacker with access to the product may execute an arbitrary command or login to the product with the administrator privilege.

CVSS 3.1 · 9.8 Critical EPSS 1.2% KEV · Not listed
Vendors
CVE-2023-25184

Use of weak credentials exists in Seiko Solutions SkyBridge and SkySpider series, which may allow a remote unauthenticated attacker to decrypt password for the WebUI of the product. Affected products and versions are as follows: SkyBridge MB-A200 firmware Ver. 01.00.05 and earlier, SkyBridge BASIC MB-A130 firmware Ver. 1.4.1 and earlier, and SkySpider MB-R210 firmware Ver. 1.01.00 and earlier.

CVSS 3.1 · 5.3 Medium EPSS < 1% KEV · Not listed
Vendors
CVE-2023-23901

Improper following of a certificate's chain of trust exists in SkyBridge MB-A200 firmware Ver. 01.00.05 and earlier, and SkyBridge BASIC MB-A130 firmware Ver. 1.4.1 and earlier, which may allow a remote unauthenticated attacker to eavesdrop on or alter the communication sent to the WebUI of the product.

CVSS 3.1 · 4.8 Medium EPSS < 1% KEV · Not listed
Vendors
CVE-2023-22441

Missing authentication for critical function exists in Seiko Solutions SkyBridge series, which may allow a remote attacker to obtain or alter the setting information of the product or execute some critical functions without authentication, e.g., rebooting the product. Affected products and versions are as follows: SkyBridge MB-A200 firmware Ver. 01.00.05 and earlier, and SkyBridge BASIC MB-A130 firmware Ver. 1.4.1 and earlier

CVSS 3.1 · 8.6 High EPSS < 1% KEV · Not listed
Vendors
CVE-2022-36560

Seiko SkyBridge MB-A200 v01.00.04 and below was discovered to contain multiple hard-coded passcodes for root. Attackers are able to access the passcodes at /etc/srapi/config/system.conf and /usr/sbin/ssol-sshd.sh.

CVSS 3.1 · 9.8 Critical EPSS < 1% KEV · Not listed
Vendors