Export limit exceeded: 425803 CVEs match your query. Please refine your search to export 10,000 CVEs or fewer.

Search vulnerabilities

Results 6

Export CSV
CVE-2020-5658

Resource Management Errors vulnerability in TCP/IP function included in the firmware of MELSEC iQ-R series (RJ71EIP91 EtherNet/IP Network Interface Module First 2 digits of serial number are '02' or before, RJ71PN92 PROFINET IO Controller Module First 2 digits of serial number are '01' or before, RD81DL96 High Speed Data Logger Module First 2 digits of serial number are '08' or before, RD81MES96N MES Interface Module First 2 digits of serial number are '04' or before, and RD81OPC96 OPC UA Server Module First 2 digits of serial number are '04' or before) allows a remote unauthenticated attacker to stop the network functions of the products via a specially crafted packet.

CVSS 3.1 · 7.5 High EPSS 2.9% KEV · Not listed
CVE-2020-5657

Improper neutralization of argument delimiters in a command ('Argument Injection') vulnerability in TCP/IP function included in the firmware of MELSEC iQ-R series (RJ71EIP91 EtherNet/IP Network Interface Module First 2 digits of serial number are '02' or before, RJ71PN92 PROFINET IO Controller Module First 2 digits of serial number are '01' or before, RD81DL96 High Speed Data Logger Module First 2 digits of serial number are '08' or before, RD81MES96N MES Interface Module First 2 digits of serial number are '04' or before, and RD81OPC96 OPC UA Server Module First 2 digits of serial number are '04' or before) allows unauthenticated attackers on adjacent network to stop the network functions of the products via a specially crafted packet.

CVSS 3.1 · 6.5 Medium EPSS 1.1% KEV · Not listed
CVE-2020-5656

Improper access control vulnerability in TCP/IP function included in the firmware of MELSEC iQ-R series (RJ71EIP91 EtherNet/IP Network Interface Module First 2 digits of serial number are '02' or before, RJ71PN92 PROFINET IO Controller Module First 2 digits of serial number are '01' or before, RD81DL96 High Speed Data Logger Module First 2 digits of serial number are '08' or before, RD81MES96N MES Interface Module First 2 digits of serial number are '04' or before, and RD81OPC96 OPC UA Server Module First 2 digits of serial number are '04' or before) allows a remote unauthenticated attacker to stop the network functions of the products or execute a malicious program via a specially crafted packet.

CVSS 3.1 · 9.8 Critical EPSS 3.0% KEV · Not listed
CVE-2020-5655

NULL pointer dereferences vulnerability in TCP/IP function included in the firmware of MELSEC iQ-R series (RJ71EIP91 EtherNet/IP Network Interface Module First 2 digits of serial number are '02' or before, RJ71PN92 PROFINET IO Controller Module First 2 digits of serial number are '01' or before, RD81DL96 High Speed Data Logger Module First 2 digits of serial number are '08' or before, RD81MES96N MES Interface Module First 2 digits of serial number are '04' or before, and RD81OPC96 OPC UA Server Module First 2 digits of serial number are '04' or before) allows a remote unauthenticated attacker to stop the network functions of the products via a specially crafted packet.

CVSS 3.1 · 7.5 High EPSS 2.9% KEV · Not listed
CVE-2020-5654

Session fixation vulnerability in TCP/IP function included in the firmware of MELSEC iQ-R series (RJ71EIP91 EtherNet/IP Network Interface Module First 2 digits of serial number are '02' or before, RJ71PN92 PROFINET IO Controller Module First 2 digits of serial number are '01' or before, RD81DL96 High Speed Data Logger Module First 2 digits of serial number are '08' or before, RD81MES96N MES Interface Module First 2 digits of serial number are '04' or before, and RD81OPC96 OPC UA Server Module First 2 digits of serial number are '04' or before) allows a remote unauthenticated attacker to stop the network functions of the products via a specially crafted packet.

CVSS 3.1 · 7.5 High EPSS 2.7% KEV · Not listed
CVE-2020-5653

Buffer overflow vulnerability in TCP/IP function included in the firmware of MELSEC iQ-R series (RJ71EIP91 EtherNet/IP Network Interface Module First 2 digits of serial number are '02' or before, RJ71PN92 PROFINET IO Controller Module First 2 digits of serial number are '01' or before, RD81DL96 High Speed Data Logger Module First 2 digits of serial number are '08' or before, RD81MES96N MES Interface Module First 2 digits of serial number are '04' or before, and RD81OPC96 OPC UA Server Module First 2 digits of serial number are '04' or before) allows a remote unauthenticated attacker to stop the network functions of the products or execute a malicious program via a specially crafted packet.

CVSS 3.1 · 9.8 Critical EPSS 3.2% KEV · Not listed