Search vulnerabilities

Results 179

Export CSV
CVE-2020-12011

A specially crafted communication packet sent to the affected systems could cause a denial-of-service condition or allow remote code execution. This issue affects: Mitsubishi Electric MC Works64 version 4.02C (10.95.208.31) and earlier, all versions; MC Works32 version 3.00A (9.50.255.02); ICONICS GenBroker64, Platform Services, Workbench, FrameWorX Server version 10.96 and prior; GenBroker32 version 9.5 and prior.

CVSS 3.1 · 9.8 Critical EPSS 29.2% KEV · Not listed
CVE-2020-12009

A specially crafted communication packet sent to the affected device could cause a denial-of-service condition due to a deserialization vulnerability. This affects: Mitsubishi Electric MC Works64 Version 4.02C (10.95.208.31) and earlier, all versions; Mitsubishi Electric MC Works32 Version 3.00A (9.50.255.02); ICONICS GenBroker64, Platform Services, Workbench, FrameWorX Server v10.96 and prior; ICONICS GenBroker32 v9.5 and prior.

CVSS 3.1 · 7.5 High EPSS 3.6% KEV · Not listed
CVE-2020-12007

A specially crafted communication packet sent to the affected devices could allow remote code execution and a denial-of-service condition due to a deserialization vulnerability. This issue affects: Mitsubishi Electric MC Works64 version 4.02C (10.95.208.31) and earlier, all versions; Mitsubishi Electric MC Works32 version 3.00A (9.50.255.02); ICONICS GenBroker64, Platform Services, Workbench, FrameWorX Server version 10.96 and prior; ICONICS GenBroker32 version 9.5 and prior.

CVSS 3.1 · 9.8 Critical EPSS 3.9% KEV · Not listed
CVE-2019-14931

An issue was discovered on Mitsubishi Electric Europe B.V. ME-RTU devices through 2.02 and INEA ME-RTU devices through 3.0. An unauthenticated remote OS Command Injection vulnerability allows an attacker to execute arbitrary commands on the RTU due to the passing of unsafe user supplied data to the RTU's system shell. Functionality in mobile.php provides users with the ability to ping sites or IP addresses via Mobile Connection Test. When the Mobile Connection Test is submitted, action.php is called to execute the test. An attacker can use a shell command separator (;) in the host variable to execute operating system commands upon submitting the test data.

CVSS 3.1 · 9.8 Critical EPSS 57.4% KEV · Not listed
Products
CVE-2019-14930

An issue was discovered on Mitsubishi Electric Europe B.V. ME-RTU devices through 2.02 and INEA ME-RTU devices through 3.0. Undocumented hard-coded user passwords for root, ineaadmin, mitsadmin, and maint could allow an attacker to gain unauthorised access to the RTU. (Also, the accounts ineaadmin and mitsadmin are able to escalate privileges to root without supplying a password due to insecure entries in /etc/sudoers on the RTU.)

CVSS 3.1 · 9.8 Critical EPSS 2.3% KEV · Not listed
Products
CVE-2019-14929

An issue was discovered on Mitsubishi Electric Europe B.V. ME-RTU devices through 2.02 and INEA ME-RTU devices through 3.0. Stored cleartext passwords could allow an unauthenticated attacker to obtain configured username and password combinations on the RTU due to the weak credentials management on the RTU. An unauthenticated user can obtain the exposed password credentials to gain access to the following services: DDNS service, Mobile Network Provider, and OpenVPN service.

CVSS 3.1 · 9.8 Critical EPSS 1.9% KEV · Not listed
Products
CVE-2019-14928

An issue was discovered on Mitsubishi Electric Europe B.V. ME-RTU devices through 2.02 and INEA ME-RTU devices through 3.0. A number of stored cross-site script (XSS) vulnerabilities allow an attacker to inject malicious code directly into the application. An example input variable vulnerable to stored XSS is SerialInitialModemString in the index.php page.

CVSS 3.1 · 5.4 Medium EPSS 43.2% KEV · Not listed
Products
CVE-2019-14927

An issue was discovered on Mitsubishi Electric Europe B.V. ME-RTU devices through 2.02 and INEA ME-RTU devices through 3.0. An unauthenticated remote configuration download vulnerability allows an attacker to download the smartRTU's configuration file (which contains data such as usernames, passwords, and other sensitive RTU data).

CVSS 3.1 · 7.5 High EPSS 40.9% KEV · Not listed
Products
CVE-2019-14926

An issue was discovered on Mitsubishi Electric Europe B.V. ME-RTU devices through 2.02 and INEA ME-RTU devices through 3.0. Hard-coded SSH keys allow an attacker to gain unauthorised access or disclose encrypted data on the RTU due to the keys not being regenerated on initial installation or with firmware updates. In other words, these devices use private-key values in /etc/ssh/ssh_host_rsa_key, /etc/ssh/ssh_host_ecdsa_key, and /etc/ssh/ssh_host_dsa_key files that are publicly available from the vendor web sites.

CVSS 3.1 · 9.8 Critical EPSS 2.1% KEV · Not listed
Products
CVE-2019-14925

An issue was discovered on Mitsubishi Electric Europe B.V. ME-RTU devices through 2.02 and INEA ME-RTU devices through 3.0. A world-readable /usr/smartrtu/init/settings.xml configuration file on the file system allows an attacker to read sensitive configuration settings such as usernames, passwords, and other sensitive RTU data due to insecure permission assignment.

CVSS 3.1 · 6.5 Medium EPSS 1.3% KEV · Not listed
Products
CVE-2019-13555

In Mitsubishi Electric MELSEC-Q Series Q03/04/06/13/26UDVCPU: serial number 21081 and prior, Q04/06/13/26UDPVCPU: serial number 21081 and prior, and Q03UDECPU, Q04/06/10/13/20/26/50/100UDEHCPU: serial number 21081 and prior, MELSEC-L Series L02/06/26CPU, L26CPU-BT: serial number 21101 and prior, L02/06/26CPU-P, L26CPU-PBT: serial number 21101 and prior, and L02/06/26CPU-CM, L26CPU-BT-CM: serial number 21101 and prior, a remote attacker can cause the FTP service to enter a denial-of-service condition dependent on the timing at which a remote attacker connects to the FTP server on the above CPU modules.

CVSS 3.1 · 5.9 Medium EPSS 1.5% KEV · Not listed
CVE-2019-10977

In Mitsubishi Electric MELSEC-Q series Ethernet module QJ71E71-100 serial number 20121 and prior, an attacker could send crafted TCP packets against the FTP service, forcing the target devices to enter an error mode and cause a denial-of-service condition.

CVSS 3.1 · 7.5 High EPSS 3.5% KEV · Not listed
CVE-2019-10972

Mitsubishi Electric FR Configurator2, Version 1.16S and prior. This vulnerability can be triggered when an attacker provides the target with a rogue project file (.frc2). Once a user opens the rogue project, CPU exhaustion occurs, which causes the software to quit responding until the application is restarted.

CVSS 3.1 · 5.5 Medium EPSS < 1% KEV · Not listed
CVE-2018-16060

Mitsubishi Electric Europe B.V. SmartRTU devices allow remote attackers to obtain sensitive information (directory listing and source code) via a direct request to the /web URI.

CVSS 3.1 · 7.5 High EPSS 19.6% KEV · Not listed
CVE-2017-9638

Mitsubishi E-Designer, Version 7.52 Build 344 contains six code sections which may be exploited to overwrite the stack. This can result in arbitrary code execution, compromised data integrity, denial of service, and system crash.

CVSS 3.0 · 9.8 Critical EPSS 3.5% KEV · Not listed
Products
CVE-2017-9636

Mitsubishi E-Designer, Version 7.52 Build 344 contains five code sections which may be exploited to overwrite the heap. This can result in arbitrary code execution, compromised data integrity, denial of service, and system crash.

CVSS 3.0 · 9.8 Critical EPSS 3.5% KEV · Not listed
Products
CVE-2017-9634

Mitsubishi E-Designer, Version 7.52 Build 344 contains two code sections which may be exploited to allow an attacker to overwrite arbitrary memory locations. This can result in arbitrary code execution, compromised data integrity, denial of service, and system crash.

CVSS 3.0 · 9.8 Critical EPSS 3.5% KEV · Not listed
Products