Search vulnerabilities

Results 1,952

Export CSV
CVE-2020-14474

The Cellebrite UFED physical device 5.0 through 7.5.0.845 relies on key material hardcoded within both the executable code supporting the decryption process, and within the encrypted files themselves by using a key enveloping technique. The recovered key material is the same for every device running the same version of the software, and does not appear to be changed with each new build. It is possible to reconstruct the decryption process using the hardcoded key material and obtain easy access to otherwise protected data.

CVSS 3.1 · 7.5 High EPSS 2.5% KEV · Not listed
Vendors
Products
CVE-2020-14099

On Xiaomi router AX1800 rom version < 1.0.336 and RM1800 root version < 1.0.26, the encryption scheme for a user's backup files uses hard-coded keys, which can expose sensitive information such as a user's password.

CVSS 3.1 · 7.5 High EPSS < 1% KEV · Not listed
Vendors
Mi
Products
CVE-2020-13963

SOPlanning before 1.47 has Incorrect Access Control because certain secret key information, and the related authentication algorithm, is public. The key for admin is hardcoded in the installation code, and there is no key for publicsp (which is a guest account).

CVSS 3.1 · 9.8 Critical EPSS 1.8% KEV · Not listed
Vendors
Products
CVE-2020-13858

An issue was discovered on Mofi Network MOFI4500-4GXeLTE 3.6.1-std and 4.0.8-std devices. They contain two undocumented administrator accounts. The sftp and mofidev accounts are defined in /etc/passwd and the password is not unique across installations.

CVSS 3.1 · 9.8 Critical EPSS 1.4% KEV · Not listed
Vendors
CVE-2020-13804

An issue was discovered in Foxit Reader and PhantomPDF before 9.7.2. It allows information disclosure of a hardcoded username and password in the DocuSign plugin.

CVSS 3.1 · 9.8 Critical EPSS 1.6% KEV · Not listed
Vendors
Products
CVE-2020-13793

Unsafe storage of AD credentials in Ivanti DSM netinst 5.1 due to a static, hard-coded encryption key.

CVSS 3.1 · 9.8 Critical EPSS 1.7% KEV · Not listed
Vendors
Products
CVE-2020-13414

An issue was discovered in Aviatrix Controller before 5.4.1204. It contains credentials unused by the software.

CVSS 3.1 · 7.5 High EPSS 1.5% KEV · Not listed
Vendors
Products
CVE-2020-13166

The management tool in MyLittleAdmin 3.8 allows remote attackers to execute arbitrary code because machineKey is hardcoded (the same for all customers' installations) in web.config, and can be used to send serialized ASP code.

CVSS 3.1 · 9.8 Critical EPSS 77.6% KEV · Not listed
Vendors
Products
CVE-2020-12627

Calibre-Web 0.6.6 allows authentication bypass because of the 'A0Zr98j/3yX R~XHH!jmN]LWX/,?RT' hardcoded secret key.

CVSS 3.1 · 9.8 Critical EPSS 1.4% KEV · Not listed
Vendors
Products
CVE-2020-12501

Pepperl+Fuchs improper authorization affects multiple Comtrol RocketLinx products

Improper Authorization vulnerability of Pepperl+Fuchs P+F Comtrol RocketLinx ES7510-XT, ES8509-XT, ES8510-XT, ES9528-XTv2, ES7506, ES7510, ES7528, ES8508, ES8508F, ES8510, ES8510-XTE, ES9528/ES9528-XT (all versions) use undocumented accounts.

CVSS 3.1 · 9.8 Critical EPSS 3.3% KEV · Not listed
CVE-2020-12376

Use of hard-coded key in the BMC firmware for some Intel(R) Server Boards, Server Systems and Compute Modules before version 2.47 may allow authenticated user to potentially enable information disclosure via local access.

CVSS 3.1 · 5.5 Medium EPSS < 1% KEV · Not listed
Vendors
Products
CVE-2020-12110

Certain TP-Link devices have a Hardcoded Encryption Key. This affects NC200 2.1.9 build 200225, N210 1.0.9 build 200304, NC220 1.3.0 build 200304, NC230 1.3.0 build 200304, NC250 1.3.0 build 200304, NC260 1.5.2 build 200304, and NC450 1.5.3 build 200304.

CVSS 3.1 · 9.8 Critical EPSS 13.6% KEV · Not listed
Vendors
Products
Nc200 Nc200 Firmware Nc210 and 11 more
CVE-2020-12039

Baxter Sigma Spectrum Infusion Pumps Sigma Spectrum Infusion System v's6.x model 35700BAX & Baxter Spectrum Infusion System v's8.x model 35700BAX2 contain hardcoded passwords when physically entered on the keypad provide access to biomedical menus including device settings, view calibration values, network configuration of Sigma Spectrum WBM if installed.

CVSS 3.1 · 2.4 Low EPSS < 1% KEV · Not listed
Vendors
CVE-2020-12035

Baxter PrismaFlex all versions, PrisMax all versions prior to 3.x, The PrismaFlex device contains a hard-coded service password that provides access to biomedical information, device settings, calibration settings, and network configuration. This could allow an attacker to modify device settings and calibration.

CVSS 3.1 · 4.9 Medium EPSS < 1% KEV · Not listed
Vendors
Products
CVE-2020-12016

Baxter ExactaMix EM 2400 & EM 1200, Versions ExactaMix EM2400 Versions 1.10, 1.11, 1.13, 1.14, ExactaMix EM1200 Versions 1.1, 1.2, 1.4, 1.5, Baxter ExactaMix EM 2400 Versions 1.10, 1.11, 1.13, 1.14 and ExactaMix EM1200 Versions 1.1, 1.2, 1.4 and 1.5 have hard-coded administrative account credentials for the ExactaMix operating system. Successful exploitation of this vulnerability may allow an attacker who has gained unauthorized access to system resources, including access to execute software or to view/update files, directories, or system configuration. This could allow an attacker with network access to view sensitive data including PHI.

CVSS 3.1 · 9.8 Critical EPSS 1.9% KEV · Not listed
Vendors
Products