Export limit exceeded: 51967 CVEs match your query. Please refine your search to export 10,000 CVEs or fewer.

Search vulnerabilities

Results 26

Export CSV
CVE-2017-7536

hibernate-validator: Privilege escalation when running under the security manager

In Hibernate Validator 5.2.x before 5.2.5 final, 5.3.x, and 5.4.x, it was found that when the security manager's reflective permissions, which allows it to access the private members of the class, are granted to Hibernate Validator, a potential privilege escalation can occur. By allowing the calling code to access those private members without the permission an attacker may be able to validate an invalid instance and access the private member value via ConstraintViolation#getInvalidValue().

CVSS 3.1 · 7.0 High EPSS < 1% KEV · Not listed
Vendors
CVE-2017-2650

It was found that the use of Pipeline: Classpath Step Jenkins plugin enables a bypass of the Script Security sandbox for users with SCM commit access, as well as users with e.g. Job/Configure permission in Jenkins.

CVSS 3.0 · 8.5 High EPSS 1.1% KEV · Not listed
Vendors
CVE-2017-12164

gdm: lock screen can be circumvented when autologin is set

A flaw was discovered in gdm 3.24.1 where gdm greeter was no longer setting the ran_once boolean during autologin. If autologin was enabled for a victim, an attacker could simply select 'login as another user' to unlock their screen.

CVSS 3.0 · 4.1 Medium EPSS < 1% KEV · Not listed
Vendors
CVE-2016-8616

curl: Case insensitive password comparison

A flaw was found in curl before version 7.51.0 When re-using a connection, curl was doing case insensitive comparisons of user name and password with the existing connections. This means that if an unused connection with proper credentials exists for a protocol that has connection-scoped credentials, an attacker can cause that connection to be reused if s/he knows the case-insensitive version of the correct password.

CVSS 3.0 · 3.7 Low EPSS 3.5% KEV · Not listed
Vendors
CVE-2014-5432

Baxter SIGMA Spectrum Infusion System version 6.05 (model 35700BAX) with wireless battery module (WBM) version 16 is remotely accessible via Port 22/SSH without authentication. A remote attacker may be able to make unauthorized configuration changes to the WBM, as well as issue commands to access account credentials and shared keys. Baxter asserts that this vulnerability only allows access to features and functionality on the WBM and that the SIGMA Spectrum infusion pump cannot be controlled from the WBM. Baxter has released a new version of the SIGMA Spectrum Infusion System, Version 8, which incorporates hardware and software changes.

CVSS 3.0 · 9.8 Critical EPSS 2.6% KEV · Not listed
Vendors