Flowintel Organization Administrator Can Reset Full Administrator Password and Escalate Privileges
Default status is the baseline for the product, each version can override it (e.g. patched versions marked unaffected).
| Vendor | Product | Default status | Versions | ||||||
|---|---|---|---|---|---|---|---|---|---|
| flowintel | flowintel | unaffected |
|
No data.
No data.
| Vendor | Product | Versions | ||||||||
|---|---|---|---|---|---|---|---|---|---|---|
| Flowintel | Flowintel |
|
No CVSS v3.1
No CVSS v3.0
No CVSS v2
This CVE is not in the KEV list.
Exploit prediction score: < 1% (0.388% probability within 30 days)
| Type | Values Removed | Values Added |
|---|---|---|
| Metrics |
ssvc
|
| Type | Values Removed | Values Added |
|---|---|---|
| First Time appeared |
Flowintel
Flowintel flowintel |
|
| Vendors & Products |
Flowintel
Flowintel flowintel |
| Type | Values Removed | Values Added |
|---|---|---|
| Description | Affected versions of Flowintel contain an authorization flaw in the administrative user-edit API. The existing authorization check correctly prevented an organization administrator from editing users in another organization, but it did not prevent them from editing a full administrator within their own organization. As a result, an org admin could modify that full administrator account, including changing its password. The upstream commit explicitly describes the issue as: “Org admin can change the password of a full admin in the same organization.” The fix adds a higher-privilege boundary check: if user_to_edit.is_admin(): return ... 403 so organization administrators can no longer modify full administrator accounts. Version impacted >=3.3.0 | |
| Title | Flowintel Organization Administrator Can Reset Full Administrator Password and Escalate Privileges | |
| Weaknesses | CWE-269 | |
| References |
| |
| Metrics |
cvssV4_0
|