CareCam CM2507 Inclusion of Functionality from Untrusted Control Sphere
Default status is the baseline for the product, each version can override it (e.g. patched versions marked unaffected).
| Vendor | Product | Default status | Versions | ||||||
|---|---|---|---|---|---|---|---|---|---|
| CareCam | HMT.CM2507 Firmware | affected |
|
No data.
No data.
| Vendor | Product | Versions | ||||||||
|---|---|---|---|---|---|---|---|---|---|---|
| Carecam | Hmt.cm2507 Firmware |
|
Vendor Workaround
CareCam has not responded to CISA's attempts to coordinate. Users are encouraged to reach out to CareCam for more information.
No CVSS v3.0
No CVSS v2
This CVE is not in the KEV list.
Exploit prediction score: < 1% (0.278% probability within 30 days)
| Type | Values Removed | Values Added |
|---|---|---|
| First Time appeared |
Carecam
Carecam hmt.cm2507 Firmware |
|
| Vendors & Products |
Carecam
Carecam hmt.cm2507 Firmware |
| Type | Values Removed | Values Added |
|---|---|---|
| Metrics |
ssvc
|
| Type | Values Removed | Values Added |
|---|---|---|
| Description | CM2507 IP cameras automatically execute a predetermined script from removable media without verifying its authenticity or integrity. An attacker with physical access to the device could supply a malicious script and execute arbitrary code in the security context of the affected device. | |
| Title | CareCam CM2507 Inclusion of Functionality from Untrusted Control Sphere | |
| Weaknesses | CWE-829 | |
| References |
| |
| Metrics |
cvssV3_1
|