PicoTronica e-Clinic Healthcare System ECHS echs.js hard-coded credentials
Default status is the baseline for the product, each version can override it (e.g. patched versions marked unaffected).
| Vendor | Product | Default status | Versions | |||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|
| PicoTronica | e-Clinic Healthcare System ECHS | affected |
|
No data.
No data.
| Vendor | Product | Versions | ||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| Picotronica | E-clinic Healthcare System Echs |
|
This CVE is not in the KEV list.
Exploit prediction score: < 1% (0.284% probability within 30 days)
| Type | Values Removed | Values Added |
|---|---|---|
| First Time appeared |
Picotronica
Picotronica e-clinic Healthcare System Echs |
|
| Vendors & Products |
Picotronica
Picotronica e-clinic Healthcare System Echs |
| Type | Values Removed | Values Added |
|---|---|---|
| Metrics |
ssvc
|
| Type | Values Removed | Values Added |
|---|---|---|
| Description | A flaw has been found in PicoTronica e-Clinic Healthcare System ECHS 5.7. The impacted element is an unknown function of the file /cdemos/echs/priv/echs.js. This manipulation of the argument ADMIN_KEY causes hard-coded credentials. The attack is possible to be carried out remotely. The exploit has been published and may be used. Upgrading to version 5.7.1 is sufficient to resolve this issue. The affected component should be upgraded. The vendor was contacted early, responded in a very professional manner and quickly released a fixed version of the affected product. | |
| Title | PicoTronica e-Clinic Healthcare System ECHS echs.js hard-coded credentials | |
| Weaknesses | CWE-259 CWE-798 |
|
| References |
| |
| Metrics |
cvssV2_0
|