PicoTronica e-Clinic Healthcare System ECHS API Endpoint patient-records missing authentication
Default status is the baseline for the product, each version can override it (e.g. patched versions marked unaffected).
| Vendor | Product | Default status | Versions | |||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|
| PicoTronica | e-Clinic Healthcare System ECHS | affected |
|
No data.
No data.
| Vendor | Product | Versions | ||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| Picotronica | E-clinic Healthcare System Echs |
|
This CVE is not in the KEV list.
Exploit prediction score: < 1% (0.394% probability within 30 days)
| Type | Values Removed | Values Added |
|---|---|---|
| First Time appeared |
Picotronica
Picotronica e-clinic Healthcare System Echs |
|
| Vendors & Products |
Picotronica
Picotronica e-clinic Healthcare System Echs |
| Type | Values Removed | Values Added |
|---|---|---|
| Metrics |
ssvc
|
| Type | Values Removed | Values Added |
|---|---|---|
| Description | A vulnerability was detected in PicoTronica e-Clinic Healthcare System ECHS 5.7. The affected element is an unknown function of the file /cdemos/echs/api/v2/patient-records of the component API Endpoint. The manipulation results in missing authentication. The attack can be executed remotely. The exploit is now public and may be used. Upgrading to version 5.7.1 is sufficient to fix this issue. You should upgrade the affected component. The vendor was contacted early, responded in a very professional manner and quickly released a fixed version of the affected product. | |
| Title | PicoTronica e-Clinic Healthcare System ECHS API Endpoint patient-records missing authentication | |
| Weaknesses | CWE-287 CWE-306 |
|
| References |
| |
| Metrics |
cvssV2_0
|