CVE-2026-79417

Improper Access Control Leading to Denial of Service via Device Handle Bypass in ArgusMonitor

Published Sep 29, 2026 CVSS 3.1 · 5.3 Medium EPSS < 1% KEV · Not listed
Description
Improper Access Control in ArgusMonitor.sys in Argotronic eGbR ArgusMonitor 7.4.02 and earlier allows local, low-privileged users to bypass device handle access restrictions via a TOCTOU condition in IRP_MJ_CREATE and send a crafted IOCTL 0x9C4024A8 request, causing denial-of-service.

Remediation

No solution or workaround provided in the CVE record

Tracking

Sign in to view the affected projects.

Advisories

No advisories available
History
Type Values Removed Values Added
Title Improper Access Control Leading to Denial of Service via Device Handle Bypass in ArgusMonitor
Type Values Removed Values Added
Title Improper Access Control Leading to Denial of Service via Crafted IOCTL
Weaknesses CWE-617
Type Values Removed Values Added
Weaknesses CWE-367
Metrics cvssV3_1

{'score': 5.3, 'vector': 'CVSS:3.1/AV:N/AC:H/PR:L/UI:N/S:U/C:N/I:N/A:H'}

ssvc

{'options': {'Automatable': 'no', 'Exploitation': 'none', 'Technical Impact': 'partial'}, 'version': '2.0.3'}

Type Values Removed Values Added
Title Improper Access Control Leading to Denial of Service via Crafted IOCTL
Weaknesses CWE-284
CWE-617
Type Values Removed Values Added
Description Improper Access Control in ArgusMonitor.sys in Argotronic eGbR ArgusMonitor 7.4.02 and earlier allows local, low-privileged users to bypass device handle access restrictions via a TOCTOU condition in IRP_MJ_CREATE and send a crafted IOCTL 0x9C4024A8 request, causing denial-of-service.
References

Subscriptions

No data.

Weaknesses

Sources

Status
PUBLISHED
Assigner
mitre
Published
Updated
Sep 30, 2026, 8:11 PM
Reserved
Aug 25, 2026, 12:00 AM
Status
Deferred
Published
Sep 29, 2026, 8:17 PM
Modified
Sep 30, 2026, 9:17 PM