{"affected": [{"affectedData": [{"defaultStatus": "unknown", "product": "SIMATIC IoT2050 Advanced (6ES7647-0BA00-1YA2)", "vendor": "Siemens", "versions": [{"lessThan": "V4.3.4-1", "status": "affected", "version": "0", "versionType": "custom"}]}, {"defaultStatus": "unknown", "product": "SIMATIC IoT2050 Advanced (6ES7647-0BA00-1YA2)", "vendor": "Siemens", "versions": [{"lessThan": "*", "status": "affected", "version": "0", "versionType": "custom"}]}, {"defaultStatus": "unknown", "product": "SIMATIC IoT2050 Basic (6ES7647-0BA00-0YA2)", "vendor": "Siemens", "versions": [{"lessThan": "V4.3.4-1", "status": "affected", "version": "0", "versionType": "custom"}]}, {"defaultStatus": "unknown", "product": "SIMATIC IoT2050 Basic (6ES7647-0BA00-0YA2)", "vendor": "Siemens", "versions": [{"lessThan": "*", "status": "affected", "version": "0", "versionType": "custom"}]}, {"defaultStatus": "unknown", "product": "SIMATIC IoT2050 M.2 (6ES7647-0BB00-1YA2)", "vendor": "Siemens", "versions": [{"lessThan": "V4.3.4-1", "status": "affected", "version": "0", "versionType": "custom"}]}, {"defaultStatus": "unknown", "product": "SIMATIC IoT2050 M.2 (6ES7647-0BB00-1YA2)", "vendor": "Siemens", "versions": [{"lessThan": "*", "status": "affected", "version": "0", "versionType": "custom"}]}, {"defaultStatus": "unknown", "product": "SIMATIC IoT2050 SM (6ES7647-0CA00-1AA2)", "vendor": "Siemens", "versions": [{"lessThan": "V4.3.4-1", "status": "affected", "version": "0", "versionType": "custom"}]}, {"defaultStatus": "unknown", "product": "SIMATIC IoT2050 SM (6ES7647-0CA00-1AA2)", "vendor": "Siemens", "versions": [{"lessThan": "*", "status": "affected", "version": "0", "versionType": "custom"}]}], "source": "productcert@siemens.com"}], "cveTags": [], "descriptions": [{"lang": "en", "value": "A vulnerability has been identified in SIMATIC IoT2050 Advanced (6ES7647-0BA00-1YA2) (All versions < V4.3.4-1 running Industrial OS with Node-RED installed), SIMATIC IoT2050 Advanced (6ES7647-0BA00-1YA2) (All versions running Example Image versions with Node-RED installed), SIMATIC IoT2050 Basic (6ES7647-0BA00-0YA2) (All versions < V4.3.4-1 running Industrial OS with Node-RED installed), SIMATIC IoT2050 Basic (6ES7647-0BA00-0YA2) (All versions running Example Image versions with Node-RED installed), SIMATIC IoT2050 M.2 (6ES7647-0BB00-1YA2) (All versions < V4.3.4-1 running Industrial OS with Node-RED installed), SIMATIC IoT2050 M.2 (6ES7647-0BB00-1YA2) (All versions running Example Image versions with Node-RED installed), SIMATIC IoT2050 SM (6ES7647-0CA00-1AA2) (All versions < V4.3.4-1 running Industrial OS with Node-RED installed), SIMATIC IoT2050 SM (6ES7647-0CA00-1AA2) (All versions running Example Image versions with Node-RED installed). Affected devices do not enforce authentication on the Node-RED HTTP interface, allowing unauthenticated access to programming nodes that are capable of executing system commands on the server.\r\nThis could allow an unauthenticated remote attacker to create malicious flows through the HTTP interface in order to execute arbitrary code on the underlying server with maximum privileges."}, {"lang": "es", "value": "Se ha identificado una vulnerabilidad en SIMATIC IoT2050 Advanced (6ES7647-0BA00-1YA2) (Todas las versiones anteriores a V4.3.4.1 que ejecutan Industrial OS con Node-RED instalado). Los dispositivos afectados no aplican autenticaci\u00f3n en la interfaz HTTP de Node-RED, lo que permite el acceso no autenticado a nodos de programaci\u00f3n que son capaces de ejecutar comandos del sistema en el servidor.\nEsto podr\u00eda permitir a un atacante remoto no autenticado crear flujos maliciosos a trav\u00e9s de la interfaz HTTP para ejecutar c\u00f3digo arbitrario en el servidor subyacente con privilegios m\u00e1ximos."}], "id": "CVE-2026-58115", "lastModified": "2026-11-10T12:17:20.330", "metrics": {"cvssMetricV31": [{"cvssData": {"attackComplexity": "LOW", "attackVector": "NETWORK", "availabilityImpact": "HIGH", "baseScore": 10.0, "baseSeverity": "CRITICAL", "confidentialityImpact": "HIGH", "integrityImpact": "HIGH", "privilegesRequired": "NONE", "scope": "CHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:C/C:H/I:H/A:H", "version": "3.1"}, "exploitabilityScore": 3.9, "impactScore": 6.0, "source": "productcert@siemens.com", "type": "Secondary"}], "cvssMetricV40": [{"cvssData": {"Automatable": "NOT_DEFINED", "Recovery": "NOT_DEFINED", "Safety": "NOT_DEFINED", "attackComplexity": "LOW", "attackRequirements": "NONE", "attackVector": "NETWORK", "availabilityRequirement": "NOT_DEFINED", "baseScore": 10.0, "baseSeverity": "CRITICAL", "confidentialityRequirement": "NOT_DEFINED", "exploitMaturity": "NOT_DEFINED", "integrityRequirement": "NOT_DEFINED", "modifiedAttackComplexity": "NOT_DEFINED", "modifiedAttackRequirements": "NOT_DEFINED", "modifiedAttackVector": "NOT_DEFINED", "modifiedPrivilegesRequired": "NOT_DEFINED", "modifiedSubAvailabilityImpact": "NOT_DEFINED", "modifiedSubConfidentialityImpact": "NOT_DEFINED", "modifiedSubIntegrityImpact": "NOT_DEFINED", "modifiedUserInteraction": "NOT_DEFINED", "modifiedVulnAvailabilityImpact": "NOT_DEFINED", "modifiedVulnConfidentialityImpact": "NOT_DEFINED", "modifiedVulnIntegrityImpact": "NOT_DEFINED", "privilegesRequired": "NONE", "providerUrgency": "NOT_DEFINED", "subAvailabilityImpact": "HIGH", "subConfidentialityImpact": "HIGH", "subIntegrityImpact": "HIGH", "userInteraction": "NONE", "valueDensity": "NOT_DEFINED", "vectorString": "CVSS:4.0/AV:N/AC:L/AT:N/PR:N/UI:N/VC:H/VI:H/VA:H/SC:H/SI:H/SA:H/E:X/CR:X/IR:X/AR:X/MAV:X/MAC:X/MAT:X/MPR:X/MUI:X/MVC:X/MVI:X/MVA:X/MSC:X/MSI:X/MSA:X/S:X/AU:X/R:X/V:X/RE:X/U:X", "version": "4.0", "vulnAvailabilityImpact": "HIGH", "vulnConfidentialityImpact": "HIGH", "vulnIntegrityImpact": "HIGH", "vulnerabilityResponseEffort": "NOT_DEFINED"}, "source": "productcert@siemens.com", "type": "Secondary"}], "ssvcV203": [{"source": "134c704f-9b21-4f2e-91b3-4a467353bcc0", "ssvcData": {"id": "CVE-2026-58115", "options": [{"exploitation": "none"}, {"automatable": "yes"}, {"technicalImpact": "total"}], "role": "CISA Coordinator", "timestamp": "2026-08-12T17:59:33.476267Z", "version": "2.0.3"}}]}, "published": "2026-08-11T13:19:00.190", "references": [{"source": "productcert@siemens.com", "url": "https://cert-portal.siemens.com/productcert/html/ssa-834709.html"}], "sourceIdentifier": "productcert@siemens.com", "vulnStatus": "Awaiting Analysis", "weaknesses": [{"description": [{"lang": "en", "value": "CWE-306"}], "source": "productcert@siemens.com", "type": "Secondary"}]}