{"affected": [{"affectedData": [{"defaultStatus": "unaffected", "product": "PowerFlex Manager", "vendor": "Dell", "versions": [{"lessThan": "5.1.0.1 or later", "status": "affected", "version": "0", "versionType": "semver"}, {"lessThan": "4.5.5.2 or later", "status": "affected", "version": "0", "versionType": "semver"}]}], "source": "security_alert@emc.com"}], "configurations": [{"nodes": [{"cpeMatch": [{"criteria": "cpe:2.3:a:dell:powerflex_manager:*:*:*:*:*:*:*:*", "matchCriteriaId": "9B1A1796-D5F8-46BD-AAE7-4C7ED2F49225", "versionEndExcluding": "4.5.5.2", "versionStartIncluding": "4.5.5", "vulnerable": true}, {"criteria": "cpe:2.3:a:dell:powerflex_manager:*:*:*:*:*:*:*:*", "matchCriteriaId": "B4E69DCB-28C5-41A7-B886-FF67BA35079F", "versionEndExcluding": "5.1.0.1", "versionStartIncluding": "5.1.0", "vulnerable": true}], "negate": false, "operator": "OR"}]}], "cveTags": [], "descriptions": [{"lang": "en", "value": "Dell PowerFlex Manager, Version prior to 5.1.0.1, contain(s) an Improper Neutralization of Special Elements used in an SQL Command ('SQL Injection') vulnerability. A low privileged attacker with remote access could potentially exploit this vulnerability, leading to Information exposure."}, {"lang": "es", "value": "Dell PowerFlex Manager, versi\u00f3n anterior a 5.1.0.1, contiene una vulnerabilidad de neutralizaci\u00f3n incorrecta de elementos especiales utilizados en un comando SQL (\u2019inyecci\u00f3n SQL\u2019). Un atacante con privilegios bajos y acceso remoto podr\u00eda potencialmente explotar esta vulnerabilidad, lo que lleva a la exposici\u00f3n de informaci\u00f3n."}], "id": "CVE-2026-56689", "lastModified": "2026-10-24T23:10:00.160", "metrics": {"cvssMetricV31": [{"cvssData": {"attackComplexity": "LOW", "attackVector": "NETWORK", "availabilityImpact": "NONE", "baseScore": 7.7, "baseSeverity": "HIGH", "confidentialityImpact": "HIGH", "integrityImpact": "NONE", "privilegesRequired": "LOW", "scope": "CHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:C/C:H/I:N/A:N", "version": "3.1"}, "exploitabilityScore": 3.1, "impactScore": 4.0, "source": "security_alert@emc.com", "type": "Secondary"}], "ssvcV203": [{"source": "134c704f-9b21-4f2e-91b3-4a467353bcc0", "ssvcData": {"id": "CVE-2026-56689", "options": [{"exploitation": "none"}, {"automatable": "no"}, {"technicalImpact": "partial"}], "role": "CISA Coordinator", "timestamp": "2026-07-10T12:59:59.557962Z", "version": "2.0.3"}}]}, "published": "2026-07-10T12:17:23.577", "references": [{"source": "security_alert@emc.com", "tags": ["Vendor Advisory"], "url": "https://www.dell.com/support/kbdoc/en-us/000477538/dsa-2026-066-security-update-for-powerflex-software-multiple-vulnerabilities"}], "sourceIdentifier": "security_alert@emc.com", "vulnStatus": "Analyzed", "weaknesses": [{"description": [{"lang": "en", "value": "CWE-89"}], "source": "security_alert@emc.com", "type": "Secondary"}]}