{"affected": [{"affectedData": [{"defaultStatus": "unknown", "product": "CPCI85 Central Processing/Communication", "vendor": "Siemens", "versions": [{"lessThan": "V26.20", "status": "affected", "version": "0", "versionType": "custom"}]}, {"defaultStatus": "unknown", "product": "SICORE Base system", "vendor": "Siemens", "versions": [{"lessThan": "V26.20.0", "status": "affected", "version": "0", "versionType": "custom"}]}], "source": "productcert@siemens.com"}], "cveTags": [], "descriptions": [{"lang": "en", "value": "A vulnerability has been identified in CPCI85 Central Processing/Communication (All versions < V26.20), SICORE Base system (All versions < V26.20.0). The affected application includes a debugging interface that is accessible through HTTP endpoints. This could allow an authenticated attacker to disrupt the system by crashing the web process causing denial of service conditions."}, {"lang": "es", "value": "Una vulnerabilidad ha sido identificada en CPCI85 Procesamiento/Comunicaci\u00f3n Central (Todas las versiones anteriores a V26.20), sistema base SICORE (Todas las versiones anteriores a V26.20.0). La aplicaci\u00f3n afectada incluye una interfaz de depuraci\u00f3n que es accesible a trav\u00e9s de puntos finales HTTP. Esto podr\u00eda permitir a un atacante autenticado interrumpir el sistema al bloquear el proceso web, causando condiciones de denegaci\u00f3n de servicio."}], "id": "CVE-2026-54798", "lastModified": "2026-10-23T23:10:00.157", "metrics": {"cvssMetricV31": [{"cvssData": {"attackComplexity": "LOW", "attackVector": "NETWORK", "availabilityImpact": "HIGH", "baseScore": 6.5, "baseSeverity": "MEDIUM", "confidentialityImpact": "NONE", "integrityImpact": "NONE", "privilegesRequired": "LOW", "scope": "UNCHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:N/I:N/A:H", "version": "3.1"}, "exploitabilityScore": 2.8, "impactScore": 3.6, "source": "productcert@siemens.com", "type": "Secondary"}], "cvssMetricV40": [{"cvssData": {"Automatable": "NOT_DEFINED", "Recovery": "NOT_DEFINED", "Safety": "NOT_DEFINED", "attackComplexity": "LOW", "attackRequirements": "NONE", "attackVector": "NETWORK", "availabilityRequirement": "NOT_DEFINED", "baseScore": 7.1, "baseSeverity": "HIGH", "confidentialityRequirement": "NOT_DEFINED", "exploitMaturity": "NOT_DEFINED", "integrityRequirement": "NOT_DEFINED", "modifiedAttackComplexity": "NOT_DEFINED", "modifiedAttackRequirements": "NOT_DEFINED", "modifiedAttackVector": "NOT_DEFINED", "modifiedPrivilegesRequired": "NOT_DEFINED", "modifiedSubAvailabilityImpact": "NOT_DEFINED", "modifiedSubConfidentialityImpact": "NOT_DEFINED", "modifiedSubIntegrityImpact": "NOT_DEFINED", "modifiedUserInteraction": "NOT_DEFINED", "modifiedVulnAvailabilityImpact": "NOT_DEFINED", "modifiedVulnConfidentialityImpact": "NOT_DEFINED", "modifiedVulnIntegrityImpact": "NOT_DEFINED", "privilegesRequired": "LOW", "providerUrgency": "NOT_DEFINED", "subAvailabilityImpact": "NONE", "subConfidentialityImpact": "NONE", "subIntegrityImpact": "NONE", "userInteraction": "NONE", "valueDensity": "NOT_DEFINED", "vectorString": "CVSS:4.0/AV:N/AC:L/AT:N/PR:L/UI:N/VC:N/VI:N/VA:H/SC:N/SI:N/SA:N/E:X/CR:X/IR:X/AR:X/MAV:X/MAC:X/MAT:X/MPR:X/MUI:X/MVC:X/MVI:X/MVA:X/MSC:X/MSI:X/MSA:X/S:X/AU:X/R:X/V:X/RE:X/U:X", "version": "4.0", "vulnAvailabilityImpact": "HIGH", "vulnConfidentialityImpact": "NONE", "vulnIntegrityImpact": "NONE", "vulnerabilityResponseEffort": "NOT_DEFINED"}, "source": "productcert@siemens.com", "type": "Secondary"}], "ssvcV203": [{"source": "134c704f-9b21-4f2e-91b3-4a467353bcc0", "ssvcData": {"id": "CVE-2026-54798", "options": [{"exploitation": "none"}, {"automatable": "no"}, {"technicalImpact": "partial"}], "role": "CISA Coordinator", "timestamp": "2026-07-09T14:52:50.609581Z", "version": "2.0.3"}}]}, "published": "2026-07-09T15:16:36.443", "references": [{"source": "productcert@siemens.com", "url": "https://cert-portal.siemens.com/productcert/html/ssa-229470.html"}], "sourceIdentifier": "productcert@siemens.com", "vulnStatus": "Awaiting Analysis", "weaknesses": [{"description": [{"lang": "en", "value": "CWE-489"}], "source": "productcert@siemens.com", "type": "Secondary"}]}