{"affected": [{"affectedData": [{"defaultStatus": "unaffected", "product": "PowerProtect Data Domain", "vendor": "Dell", "versions": [{"lessThan": "8.8.0.0 or later", "status": "affected", "version": "0", "versionType": "semver"}, {"lessThan": "8.6.1.20 or later", "status": "affected", "version": "0", "versionType": "semver"}, {"lessThan": "8.3.1.40 or later", "status": "affected", "version": "0", "versionType": "semver"}, {"lessThan": "7.13.1.80 or later", "status": "affected", "version": "0", "versionType": "semver"}]}], "source": "security_alert@emc.com"}], "configurations": [{"nodes": [{"cpeMatch": [{"criteria": "cpe:2.3:o:dell:data_domain_operating_system:*:*:*:*:*:*:*:*", "matchCriteriaId": "064F56BA-B974-4133-9DFA-B13D503766AC", "versionEndExcluding": "7.13.1.80", "versionStartIncluding": "7.7.1.0", "vulnerable": true}, {"criteria": "cpe:2.3:o:dell:data_domain_operating_system:*:*:*:*:*:*:*:*", "matchCriteriaId": "EB4BB568-B169-4202-94E0-8D808419241B", "versionEndExcluding": "8.3.1.40", "versionStartIncluding": "7.14.0.0", "vulnerable": true}, {"criteria": "cpe:2.3:o:dell:data_domain_operating_system:*:*:*:*:*:*:*:*", "matchCriteriaId": "BA61361F-FED8-4936-A9F6-FFA35BE413F8", "versionEndExcluding": "8.6.1.20", "versionStartIncluding": "8.4.0.0", "vulnerable": true}, {"criteria": "cpe:2.3:o:dell:data_domain_operating_system:*:*:*:*:*:*:*:*", "matchCriteriaId": "4BA45B0F-6A67-476D-9101-0DDC91B77D51", "versionEndExcluding": "8.8.0.0", "versionStartIncluding": "8.7.0.0", "vulnerable": true}], "negate": false, "operator": "OR"}]}], "cveTags": [], "descriptions": [{"lang": "en", "value": "Dell PowerProtect Data Domain, versions 7.7.1.0 through 8.7, LTS2026 release version 8.6.1.0 through 8.6.1.10, LTS2025 release version 8.3.1.0 through 8.3.1.30, LTS2024 release versions 7.13.1.0 through 7.13.1.70 contain an improper limitation of a pathname to a restricted directory ('path traversal') vulnerability. A high privileged attacker with remote access could potentially exploit this vulnerability, leading to unauthorized file modification."}, {"lang": "es", "value": "Dell PowerProtect Data Domain, versiones 7.7.1.0 hasta 8.7, versi\u00f3n de lanzamiento LTS2026 8.6.1.0 hasta 8.6.1.10, versi\u00f3n de lanzamiento LTS2025 8.3.1.0 hasta 8.3.1.30, versiones de lanzamiento LTS2024 7.13.1.0 hasta 7.13.1.70 contienen una vulnerabilidad de limitaci\u00f3n inadecuada de un nombre de ruta a un directorio restringido (\u2019salto de ruta\u2019). Un atacante con altos privilegios con acceso remoto podr\u00eda potencialmente explotar esta vulnerabilidad, lo que podr\u00eda llevar a la modificaci\u00f3n no autorizada de archivos."}], "id": "CVE-2026-53480", "lastModified": "2026-10-25T20:10:00.147", "metrics": {"cvssMetricV31": [{"cvssData": {"attackComplexity": "LOW", "attackVector": "NETWORK", "availabilityImpact": "NONE", "baseScore": 2.7, "baseSeverity": "LOW", "confidentialityImpact": "NONE", "integrityImpact": "LOW", "privilegesRequired": "HIGH", "scope": "UNCHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.1/AV:N/AC:L/PR:H/UI:N/S:U/C:N/I:L/A:N", "version": "3.1"}, "exploitabilityScore": 1.2, "impactScore": 1.4, "source": "security_alert@emc.com", "type": "Secondary"}], "ssvcV203": [{"source": "134c704f-9b21-4f2e-91b3-4a467353bcc0", "ssvcData": {"id": "CVE-2026-53480", "options": [{"exploitation": "none"}, {"automatable": "no"}, {"technicalImpact": "partial"}], "role": "CISA Coordinator", "timestamp": "2026-07-08T14:29:20.663485Z", "version": "2.0.3"}}]}, "published": "2026-07-08T14:17:03.880", "references": [{"source": "security_alert@emc.com", "tags": ["Vendor Advisory"], "url": "https://www.dell.com/support/kbdoc/en-us/000481268/dsa-2026-278-security-update-for-dell-powerprotect-data-domain-multiple-vulnerabilities?msockid=3021cac2195069ed3194ddad186a68f9"}], "sourceIdentifier": "security_alert@emc.com", "vulnStatus": "Analyzed", "weaknesses": [{"description": [{"lang": "en", "value": "CWE-22"}], "source": "security_alert@emc.com", "type": "Secondary"}]}