CVE-2026-49325

Indian Scout Bobber 2025 WCM voltage-based shutdown

Published May 29, 2026 CVSS 4.0 · 4.1 Medium EPSS < 1% KEV · Not listed
Description
Improper handling of physical conditions in the bike-shutdown control of the Indian Motorcycle Scout Bobber + Tech 2025 model year allows a physical attacker with access to the Wireless Control Module (WCM) wiring harness to bypass the anti-theft shutdown. The WCM signals shutdown to a peer ECU via a falling-edge voltage transition on a dedicated wire pair. The receiving ECU does not distinguish between an active shutdown pulse and an open-circuit / disconnected condition; interrupting the relevant wires leaves the motorcycle fully operable even though the WCM never validated the rider's PIN. Specific connector details have been withheld pending vendor remediation.

Remediation

Vendor Solution

Use a positive-validation heartbeat: the receiving ECU should require a periodic rising-edge or signed message from the WCM and treat its absence as the shutdown command (fail-secure). Combine with CAN-A liveness validation. Add tamper-evident sealing on the WCM connector.

Tracking

Sign in to view the affected projects.

Advisories

No advisories available
History
Type Values Removed Values Added
Metrics ssvc

{'options': {'Automatable': 'no', 'Exploitation': 'none', 'Technical Impact': 'partial'}, 'version': '2.0.3'}

Type Values Removed Values Added
First Time appeared Indian Motorcycle
Indian Motorcycle scout Bobber + Tech
Vendors & Products Indian Motorcycle
Indian Motorcycle scout Bobber + Tech
Type Values Removed Values Added
Description Improper handling of physical conditions in the bike-shutdown control of the Indian Motorcycle Scout Bobber + Tech 2025 model year allows a physical attacker with access to the Wireless Control Module (WCM) wiring harness to bypass the anti-theft shutdown. The WCM signals shutdown to a peer ECU via a falling-edge voltage transition on a dedicated wire pair. The receiving ECU does not distinguish between an active shutdown pulse and an open-circuit / disconnected condition; interrupting the relevant wires leaves the motorcycle fully operable even though the WCM never validated the rider's PIN. Specific connector details have been withheld pending vendor remediation.
Title Indian Scout Bobber 2025 WCM voltage-based shutdown
Weaknesses CWE-1384
CWE-693
CWE-754
References
Metrics cvssV3_1

{'score': 4.6, 'vector': 'CVSS:3.1/AV:P/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H'}

cvssV4_0

{'score': 4.1, 'vector': 'CVSS:4.0/AV:P/AC:L/AT:P/PR:N/UI:N/VC:N/VI:N/VA:H/SC:N/SI:N/SA:N'}

Weaknesses

Sources

Status
PUBLISHED
Assigner
ASRG
Published
Updated
Jun 27, 2026, 8:47 AM
Reserved
May 29, 2026, 7:26 AM
Status
Deferred
Published
May 29, 2026, 2:16 PM
Modified