CVE-2026-40623

SenseLive X3050 Missing Authorization

Published Apr 23, 2026 CVSS 4.0 · 7.2 High EPSS < 1% KEV · Not listed
Description
A vulnerability in SenseLive X3050's web management interface allows critical system and network configuration parameters to be modified without sufficient validation and safety controls. Due to inadequate enforcement of constraints on sensitive functions, parameters such as IP addressing, watchdog timers, reconnect intervals, and service ports can be set to unsupported or unsafe values. These configuration changes directly affect core device behaviour and recovery mechanisms. The lack of proper validation and safeguards allows critical system functions to be altered in a manner that can destabilize device operation or render the device persistently unavailable.

Remediation

Vendor Solution

SenseLive did not respond to CISA's requests to coordinate. Affected users are encouraged to reach out to SenseLive for more information. https://senselive.io/contact

Tracking

Sign in to view the affected projects.

Advisories

No advisories available
History
Type Values Removed Values Added
First Time appeared Senselive x3500
Senselive x3500 Firmware
CPEs cpe:2.3:h:senselive:x3500:-:*:*:*:*:*:*:*
cpe:2.3:o:senselive:x3500_firmware:1.523:*:*:*:*:*:*:*
Vendors & Products Senselive x3500
Senselive x3500 Firmware
Type Values Removed Values Added
First Time appeared Senselive
Senselive x3050
Vendors & Products Senselive
Senselive x3050
Type Values Removed Values Added
Metrics ssvc

{'options': {'Automatable': 'no', 'Exploitation': 'none', 'Technical Impact': 'partial'}, 'version': '2.0.3'}

Type Values Removed Values Added
Description A vulnerability in SenseLive X3050's web management interface allows critical system and network configuration parameters to be modified without sufficient validation and safety controls. Due to inadequate enforcement of constraints on sensitive functions, parameters such as IP addressing, watchdog timers, reconnect intervals, and service ports can be set to unsupported or unsafe values. These configuration changes directly affect core device behaviour and recovery mechanisms. The lack of proper validation and safeguards allows critical system functions to be altered in a manner that can destabilize device operation or render the device persistently unavailable.
Title SenseLive X3050 Missing Authorization
Weaknesses CWE-862
References
Metrics cvssV3_1

{'score': 8.1, 'vector': 'CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:N/I:H/A:H'}

cvssV4_0

{'score': 7.2, 'vector': 'CVSS:4.0/AV:N/AC:L/AT:N/PR:L/UI:N/VC:N/VI:H/VA:H/SC:N/SI:N/SA:N'}

Weaknesses

Sources

Status
PUBLISHED
Assigner
icscert
Published
Updated
Apr 24, 2026, 6:18 PM
Reserved
Apr 14, 2026, 3:57 PM
Status
Analyzed
Published
Apr 24, 2026, 12:16 AM
Modified
Oct 26, 2026, 9:10 PM