Red Lion Controls N-Tron 700 Series Insufficiently Protected Credentials
Default status is the baseline for the product, each version can override it (e.g. patched versions marked unaffected).
| Vendor | Product | Default status | Versions | ||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| Red Lion Controls | 700 Series | unaffected |
|
No data.
No data.
| Vendor | Product | Versions | ||||||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| Red Lion Controls | 700 Series |
|
Vendor Solution
Red Lion controls recommends the following upgrades for the N-Tron 700 Series: * Upgrade to firmware version 3.11.1 or greater * Configure or disable the SNMP communities * Disable access to the web GUI The upgrade procedure document can be viewed here https://www.hms-networks.com/ . The advisory issued by HMS Networks regarding these vulnerabilities can be viewed here https://www.hms-networks.com/cybersecurity .
No CVSS v3.0
No CVSS v2
This CVE is not in the KEV list.
Exploit prediction score: < 1% (0.291% probability within 30 days)
| Type | Values Removed | Values Added |
|---|---|---|
| Metrics |
ssvc
|
| Type | Values Removed | Values Added |
|---|---|---|
| First Time appeared |
Red Lion Controls
Red Lion Controls 700 Series |
|
| Vendors & Products |
Red Lion Controls
Red Lion Controls 700 Series |
| Type | Values Removed | Values Added |
|---|---|---|
| Description | Usernames and passwords, including the default factory credentials, are stored in plaintext within the configuration file. With administrator rights, the configuration file can be viewed through the CLI or they can be exported from the device through a TFTP transfer from the web interface. A TFTP transfer can be initiated through SNMP which does not require authentication. | |
| Title | Red Lion Controls N-Tron 700 Series Insufficiently Protected Credentials | |
| Weaknesses | CWE-522 | |
| References |
| |
| Metrics |
cvssV3_1
|