CVE-2026-3555

Philips Hue Bridge Zigbee Stack Custom Command Handler Heap-based Buffer Overflow Remote Code Execution Vulnerability

Published Mar 13, 2026 CVSS 3.0 · 8 High EPSS < 1% KEV · Not listed
Description
Philips Hue Bridge Zigbee Stack Custom Command Handler Heap-based Buffer Overflow Remote Code Execution Vulnerability. This vulnerability allows network-adjacent attackers to execute arbitrary code on affected installations of Philips Hue Bridge. User interaction is required to exploit this vulnerability in that the user must initiate the device pairing process.

The specific flaw exists within the handling of custom Zigbee ZCL frames in the Model Info download functionality. The issue results from the lack of proper validation of the size of data prior to copying it to a fixed-size heap buffer. An attacker can leverage this vulnerability to execute code in the context of the device. Was ZDI-CAN-28276.

Remediation

No solution or workaround provided in the CVE record

Tracking

Sign in to view the affected projects.

Advisories

No advisories available
History
Type Values Removed Values Added
First Time appeared Philips
Philips hue Bridge V2
Philips hue Bridge V2 Firmware
CPEs cpe:2.3:h:philips:hue_bridge_v2:-:*:*:*:*:*:*:*
cpe:2.3:o:philips:hue_bridge_v2_firmware:*:*:*:*:*:*:*:*
Vendors & Products Philips
Philips hue Bridge V2
Philips hue Bridge V2 Firmware
Type Values Removed Values Added
Metrics ssvc

{'options': {'Automatable': 'no', 'Exploitation': 'none', 'Technical Impact': 'total'}, 'version': '2.0.3'}

Type Values Removed Values Added
First Time appeared Phillips
Phillips hue Bridge
Vendors & Products Phillips
Phillips hue Bridge
Type Values Removed Values Added
Description Philips Hue Bridge Zigbee Stack Custom Command Handler Heap-based Buffer Overflow Remote Code Execution Vulnerability. This vulnerability allows network-adjacent attackers to execute arbitrary code on affected installations of Philips Hue Bridge. User interaction is required to exploit this vulnerability in that the user must initiate the device pairing process. The specific flaw exists within the handling of custom Zigbee ZCL frames in the Model Info download functionality. The issue results from the lack of proper validation of the size of data prior to copying it to a fixed-size heap buffer. An attacker can leverage this vulnerability to execute code in the context of the device. Was ZDI-CAN-28276.
Title Philips Hue Bridge Zigbee Stack Custom Command Handler Heap-based Buffer Overflow Remote Code Execution Vulnerability
Weaknesses CWE-122
References
Metrics cvssV3_0

{'score': 8, 'vector': 'CVSS:3.0/AV:A/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H'}

Weaknesses

Sources

Status
PUBLISHED
Assigner
zdi
Published
Updated
Mar 16, 2026, 8:16 PM
Reserved
Mar 4, 2026, 7:42 PM
Status
Analyzed
Published
Mar 16, 2026, 2:19 PM
Modified
Jun 17, 2026, 10:43 AM