Red Lion Controls N-Tron 700 Series Authentication Bypass Using an Alternate Path or Channel
Default status is the baseline for the product, each version can override it (e.g. patched versions marked unaffected).
| Vendor | Product | Default status | Versions | ||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| Red Lion Controls | 700 Series | unaffected |
|
No data.
No data.
| Vendor | Product | Versions | ||||||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| Red Lion Controls | 700 Series |
|
Vendor Solution
Red Lion controls recommends the following upgrades for the N-Tron 700 Series: * Upgrade to firmware version 3.11.1 or greater * Configure or disable the SNMP communities * Disable access to the web GUI The upgrade procedure document can be viewed here https://www.hms-networks.com/ . The advisory issued by HMS Networks regarding these vulnerabilities can be viewed here https://www.hms-networks.com/cybersecurity .
No CVSS v3.0
No CVSS v2
This CVE is not in the KEV list.
Exploit prediction score: < 1% (0.150% probability within 30 days)
| Type | Values Removed | Values Added |
|---|---|---|
| Metrics |
ssvc
|
| Type | Values Removed | Values Added |
|---|---|---|
| First Time appeared |
Red Lion Controls
Red Lion Controls 700 Series |
|
| Vendors & Products |
Red Lion Controls
Red Lion Controls 700 Series |
| Type | Values Removed | Values Added |
|---|---|---|
| Description | A malicious user with physical access to the device can boot the switch from factory settings without authentication, use the default administrative credentials to obtain administrative access, and save changes to the configuration file so that they persist next time the switch boots normally. | |
| Title | Red Lion Controls N-Tron 700 Series Authentication Bypass Using an Alternate Path or Channel | |
| Weaknesses | CWE-288 | |