CVE-2026-27843

SenseLive X3050 Missing authentication for critical function

Published Apr 23, 2026 CVSS 4.0 · 9.2 Critical EPSS < 1% KEV · Not listed
Description
A vulnerability exists in SenseLive X3050's web management interface that allows critical configuration parameters to be modified without sufficient authentication or server-side validation. By applying unsupported or disruptive values to recovery mechanisms and network settings, an attacker can induce a persistent lockout state. Because the device lacks a physical reset button, recovery requires specialized technical access via the console to perform a factory reset, resulting in a total denial-of-service for the gateway and its connected RS-485 downstream systems.

Remediation

Vendor Solution

SenseLive did not respond to CISA's requests to coordinate. Affected users are encouraged to reach out to SenseLive for more information. https://senselive.io/contact

Tracking

Sign in to view the affected projects.

Advisories

No advisories available
History
Type Values Removed Values Added
First Time appeared Senselive x3500
Senselive x3500 Firmware
CPEs cpe:2.3:h:senselive:x3500:-:*:*:*:*:*:*:*
cpe:2.3:o:senselive:x3500_firmware:1.523:*:*:*:*:*:*:*
Vendors & Products Senselive x3500
Senselive x3500 Firmware
Type Values Removed Values Added
First Time appeared Senselive
Senselive x3050
Vendors & Products Senselive
Senselive x3050
Type Values Removed Values Added
Metrics ssvc

{'options': {'Automatable': 'yes', 'Exploitation': 'none', 'Technical Impact': 'total'}, 'version': '2.0.3'}

Type Values Removed Values Added
Description A vulnerability exists in SenseLive X3050's web management interface that allows critical configuration parameters to be modified without sufficient authentication or server-side validation. By applying unsupported or disruptive values to recovery mechanisms and network settings, an attacker can induce a persistent lockout state. Because the device lacks a physical reset button, recovery requires specialized technical access via the console to perform a factory reset, resulting in a total denial-of-service for the gateway and its connected RS-485 downstream systems.
Title SenseLive X3050 Missing authentication for critical function
Weaknesses CWE-306
References
Metrics cvssV3_1

{'score': 9.1, 'vector': 'CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:H/A:H'}

cvssV4_0

{'score': 9.2, 'vector': 'CVSS:4.0/AV:N/AC:L/AT:N/PR:N/UI:N/VC:N/VI:H/VA:H/SC:N/SI:N/SA:H'}

Weaknesses

Sources

Status
PUBLISHED
Assigner
icscert
Published
Updated
Apr 24, 2026, 1:10 PM
Reserved
Apr 14, 2026, 4:05 PM
Status
Analyzed
Published
Apr 24, 2026, 12:16 AM
Modified
Oct 26, 2026, 9:10 PM