CVE-2026-25857

Tenda G300-F Command Injection via formSetWanDiag

Published Feb 7, 2026 CVSS 4.0 · 8.6 High EPSS 3.1% KEV · Not listed
Description
Tenda G300-F router firmware version 16.01.14.2 and prior contain an OS command injection vulnerability in the WAN diagnostic functionality (formSetWanDiag). The implementation constructs a shell command that invokes curl and incorporates attacker-controlled input into the command line without adequate neutralization. As a result, a remote attacker with access to the affected management interface can inject additional shell syntax and execute arbitrary commands on the device with the privileges of the management process.

Remediation

No solution or workaround provided in the CVE record

Tracking

Sign in to view the affected projects.

Advisories

No advisories available
History
Type Values Removed Values Added
First Time appeared Tenda g300-f Firmware
CPEs cpe:2.3:h:tenda:g300-f:1.0:*:*:*:*:*:*:*
cpe:2.3:o:tenda:g300-f_firmware:*:*:*:*:*:*:*:*
Vendors & Products Tenda g300-f Firmware
Metrics cvssV3_1

{'score': 8.8, 'vector': 'CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H'}

Type Values Removed Values Added
First Time appeared Tenda rx9 Pro Firmware
CPEs cpe:2.3:o:tenda:rx9_pro_firmware:*:*:*:*:*:*:*:*
Vendors & Products Tenda rx9 Pro Firmware
Type Values Removed Values Added
Description Tenda G300-F router firmware versio 16.01.14.2 and prior contain an OS command injection vulnerability in the WAN diagnostic functionality (formSetWanDiag). The implementation constructs a shell command that invokes curl and incorporates attacker-controlled input into the command line without adequate neutralization. As a result, a remote attacker with access to the affected management interface can inject additional shell syntax and execute arbitrary commands on the device with the privileges of the management process. Tenda G300-F router firmware version 16.01.14.2 and prior contain an OS command injection vulnerability in the WAN diagnostic functionality (formSetWanDiag). The implementation constructs a shell command that invokes curl and incorporates attacker-controlled input into the command line without adequate neutralization. As a result, a remote attacker with access to the affected management interface can inject additional shell syntax and execute arbitrary commands on the device with the privileges of the management process.
Type Values Removed Values Added
Metrics ssvc

{'options': {'Automatable': 'no', 'Exploitation': 'poc', 'Technical Impact': 'total'}, 'version': '2.0.3'}

Type Values Removed Values Added
First Time appeared Tenda
Tenda g300-f
Vendors & Products Tenda
Tenda g300-f
Type Values Removed Values Added
Description Tenda G300-F router firmware versio 16.01.14.2 and prior contain an OS command injection vulnerability in the WAN diagnostic functionality (formSetWanDiag). The implementation constructs a shell command that invokes curl and incorporates attacker-controlled input into the command line without adequate neutralization. As a result, a remote attacker with access to the affected management interface can inject additional shell syntax and execute arbitrary commands on the device with the privileges of the management process.
Title Tenda G300-F Command Injection via formSetWanDiag
Weaknesses CWE-78
References
Metrics cvssV4_0

{'score': 8.6, 'vector': 'CVSS:4.0/AV:N/AC:L/AT:N/PR:H/UI:N/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N'}

Weaknesses

Sources

Status
PUBLISHED
Assigner
VulnCheck
Published
Updated
May 11, 2026, 11:11 PM
Reserved
Feb 6, 2026, 7:12 PM
Status
Analyzed
Published
Feb 7, 2026, 10:16 PM
Modified
Jun 17, 2026, 10:25 AM