Arista EOS IPsec Tunnel Sequence Number Mismatch via Interface Flaps when Anti-Replay is Disabled
Default status is the baseline for the product, each version can override it (e.g. patched versions marked unaffected).
| Vendor | Product | Default status | Versions | |||||||||||||||||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| Arista Networks | EOS | unaffected |
|
No data.
No data.
| Vendor | Product | Versions | ||||||||||||||||||||||||||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| Arista | Eos |
|
Vendor Solution
The recommended resolution is to upgrade to a remediated software version at your earliest convenience. Arista recommends customers move to the latest version of each release that contains all the fixes listed below. For more information about upgrading see: EOS User Manual: Upgrades and Downgrades https://www.arista.com/en/um-eos/eos-upgrades-and-downgrades CVE-2026-2379 has been fixed in the following releases: * 4.35.0F and later releases in the 4.35.x train * 4.34.4M and later releases in the 4.34.x train * 4.33.6M and later releases in the 4.33.x train * 4.32.8M and later releases in the 4.32.x train * 4.31.10M and later releases in the 4.31.x train
Vendor Workaround
There is no known mitigation for CVE-2026-2379. The recommended resolution is to upgrade to a remediated software version at your earliest convenience.
No CVSS v3.0
No CVSS v2
This CVE is not in the KEV list.
Exploit prediction score: < 1% (0.226% probability within 30 days)
| Type | Values Removed | Values Added |
|---|---|---|
| Metrics |
ssvc
|
| Type | Values Removed | Values Added |
|---|---|---|
| First Time appeared |
Arista
Arista eos |
|
| Vendors & Products |
Arista
Arista eos |
| Type | Values Removed | Values Added |
|---|---|---|
| Description | On affected platforms with hardware IPSec support running Arista EOS with certain IPsec features enabled, EOS may exhibit unexpected behavior in specific cases. Physical interface flaps and certain agent restarts can cause IPsec tunnel re-establishment with existing Security Associations, resulting in sequence number mismatches between tunnel endpoints potentially causing unstable communication. | |
| Title | Arista EOS IPsec Tunnel Sequence Number Mismatch via Interface Flaps when Anti-Replay is Disabled | |
| Weaknesses | CWE-672 | |
| References |
| |
| Metrics |
cvssV3_1
|