CVE-2026-22755

Legacy Vivotek Camera Firmware Command Injection in upload_map.cgi

Published Jan 13, 2026 CVSS 4.0 · 9.3 Critical EPSS 13.8% KEV · Not listed
Description
Improper Neutralization of Special Elements used in a Command ('Command Injection') vulnerability in Vivotek Affected device model numbers are FD8365, FD8365v2, FD9165, FD9171, FD9187, FD9189, FD9365, FD9371, FD9381, FD9387, FD9389, FD9391,FE9180,FE9181, FE9191, FE9381, FE9382, FE9391, FE9582, IB9365, IB93587LPR, IB9371,IB9381, IB9387, IB9389, IB939,IP9165,IP9171, IP9172, IP9181, IP9191, IT9389, MA9321, MA9322, MS9321, MS9390, TB9330 (Firmware modules) allows OS Command Injection.This issue affects Affected device model numbers are FD8365, FD8365v2, FD9165, FD9171, FD9187, FD9189, FD9365, FD9371, FD9381, FD9387, FD9389, FD9391,FE9180,FE9181, FE9191, FE9381, FE9382, FE9391, FE9582, IB9365, IB93587LPR, IB9371,IB9381, IB9387, IB9389, IB939,IP9165,IP9171, IP9172, IP9181, IP9191, IT9389, MA9321, MA9322, MS9321, MS9390, TB9330: 0100a, 0106a, 0106b, 0107a, 0107b_1, 0109a, 0112a, 0113a, 0113d, 0117b, 0119e, 0120b, 0121, 0121d, 0121d_48573_1, 0122e, 0124d_48573_1, 012501, 012502, 0125c.

Remediation

No solution or workaround provided in the CVE record

Tracking

Sign in to view the affected projects.

Advisories

No advisories available
History
Type Values Removed Values Added
Title Remote code injection via upload_map.cgi in Legacy Vivotek Devices Legacy Vivotek Camera Firmware Command Injection in upload_map.cgi
References
Type Values Removed Values Added
First Time appeared Vivotek
Vivotek fd8365
Vivotek fd8365v2
Vivotek fd9165
Vivotek fd9171
Vivotek fd9187
Vivotek fd9189
Vivotek fd9365
Vivotek fd9371
Vivotek fd9381
Vivotek fd9387
Vivotek fd9389
Vivotek fd9391
Vivotek fe9180
Vivotek fe9181
Vivotek fe9191
Vivotek fe9381
Vivotek fe9382
Vivotek fe9391
Vivotek fe9582
Vivotek ib93587lpr
Vivotek ib9365
Vivotek ib9371
Vivotek ib9381
Vivotek ib9387
Vivotek ib9389
Vivotek ib939
Vivotek ip9165
Vivotek ip9171
Vivotek ip9172
Vivotek ip9181
Vivotek ip9191
Vivotek it9389
Vivotek ma9321
Vivotek ma9322
Vivotek ms9321
Vivotek ms9390
Vivotek tb9330
Vendors & Products Vivotek
Vivotek fd8365
Vivotek fd8365v2
Vivotek fd9165
Vivotek fd9171
Vivotek fd9187
Vivotek fd9189
Vivotek fd9365
Vivotek fd9371
Vivotek fd9381
Vivotek fd9387
Vivotek fd9389
Vivotek fd9391
Vivotek fe9180
Vivotek fe9181
Vivotek fe9191
Vivotek fe9381
Vivotek fe9382
Vivotek fe9391
Vivotek fe9582
Vivotek ib93587lpr
Vivotek ib9365
Vivotek ib9371
Vivotek ib9381
Vivotek ib9387
Vivotek ib9389
Vivotek ib939
Vivotek ip9165
Vivotek ip9171
Vivotek ip9172
Vivotek ip9181
Vivotek ip9191
Vivotek it9389
Vivotek ma9321
Vivotek ma9322
Vivotek ms9321
Vivotek ms9390
Vivotek tb9330
Type Values Removed Values Added
Metrics ssvc

{'options': {'Automatable': 'yes', 'Exploitation': 'poc', 'Technical Impact': 'total'}, 'version': '2.0.3'}

Type Values Removed Values Added
Title Use of default login credentials in Legacy Vivotek Devices Remote code injection via upload_map.cgi in Legacy Vivotek Devices
Type Values Removed Values Added
Description Improper Neutralization of Special Elements used in a Command ('Command Injection') vulnerability in Vivotek Affected device model numbers are FD8365, FD8365v2, FD9165, FD9171, FD9187, FD9189, FD9365, FD9371, FD9381, FD9387, FD9389, FD9391,FE9180,FE9181, FE9191, FE9381, FE9382, FE9391, FE9582, IB9365, IB93587LPR, IB9371,IB9381, IB9387, IB9389, IB939,IP9165,IP9171, IP9172, IP9181, IP9191, IT9389, MA9321, MA9322, MS9321, MS9390, TB9330 (Firmware modules) allows OS Command Injection.This issue affects Affected device model numbers are FD8365, FD8365v2, FD9165, FD9171, FD9187, FD9189, FD9365, FD9371, FD9381, FD9387, FD9389, FD9391,FE9180,FE9181, FE9191, FE9381, FE9382, FE9391, FE9582, IB9365, IB93587LPR, IB9371,IB9381, IB9387, IB9389, IB939,IP9165,IP9171, IP9172, IP9181, IP9191, IT9389, MA9321, MA9322, MS9321, MS9390, TB9330: 0100a, 0106a, 0106b, 0107a, 0107b_1, 0109a, 0112a, 0113a, 0113d, 0117b, 0119e, 0120b, 0121, 0121d, 0121d_48573_1, 0122e, 0124d_48573_1, 012501, 012502, 0125c.
Title Use of default login credentials in Legacy Vivotek Devices
Weaknesses CWE-77
References
Metrics cvssV4_0

{'score': 9.3, 'vector': 'CVSS:4.0/AV:N/AC:L/AT:N/PR:N/UI:N/VC:H/VI:H/VA:H/SC:H/SI:H/SA:H/E:P/AU:Y/U:Amber'}