CVE-2026-16828

Power System Out-of-bounds Read

Published Aug 19, 2026 CVSS 3.1 · 7.6 High EPSS < 1% KEV · Not listed
Description
IBM Power Systems Firmware FW1120.00, FW1110.00 through FW1110.30, FW1060.00 through FW1060.80, and FW950.00 through FW950.H2 is affected by a vulnerability in the ASMI web interface. An unauthenticated attacker on the management network can cause the ASMI web server to crash with possible memory corruption and generate an error log; hosted partitions are not affected. The ASMI web interface will restart automatically; however, repeated exploitation could result in a sustained loss of access to the ASMI management interface, resulting in an integrity and availability impact.

Remediation

Vendor Solution

Customers with the products below should install FW1120.01(1120_167), FW1110.31(1110_134) or newer to remediate this vulnerability. Power 11 1) IBM Power System E1180 (9080-HEU) Customers with the products below should install FW1060.81(1060_184) or newer to remediate this vulnerability. Power 10 1) IBM Power System E1080 (9080-HEX) Customers with the products below should install FW950.H3(950_230) or newer to remediate this vulnerability. Power 9 1) IBM Power System S922 (9009-22G) 2) IBM Power System H922 (9223-22S) 3) IBM Power System S914 (9009-41G) 4) IBM Power System S924 (9009-42G) 5) IBM Power System H924 (9223-42S) 6) IBM Power System E950 (9040-MR9) 7) IBM Power System E980 (9080-M9S) The images mentioned above can be located at IBM Fix Central : https://www.ibm.com/support/fixcentral/


Vendor Workaround

Protect access to the FSP's network interface.

Tracking

Sign in to view the affected projects.

Advisories

No advisories available
History
Type Values Removed Values Added
Metrics ssvc

{'options': {'Automatable': 'no', 'Exploitation': 'none', 'Technical Impact': 'partial'}, 'version': '2.0.3'}

Type Values Removed Values Added
First Time appeared Ibm power System E1080 \(9080-hex\)
Ibm power System E1080 \(9080-hex\) Firmware
Ibm power System E1180 \(9080-heu\)
Ibm power System E1180 \(9080-heu\) Firmware
Ibm power System E950 \(9040-mr9\)
Ibm power System E950 \(9040-mr9\) Firmware
Ibm power System E980 \(9080-m9s\)
Ibm power System E980 \(9080-m9s\) Firmware
Ibm power System H922 \(9223-22s\)
Ibm power System H922 \(9223-22s\) Firmware
Ibm power System H924 \(9223-42s\)
Ibm power System H924 \(9223-42s\) Firmware
Ibm power System S914 \(9009-41g\)
Ibm power System S914 \(9009-41g\) Firmware
Ibm power System S922 \(9009-22g\)
Ibm power System S922 \(9009-22g\) Firmware
Ibm power System S924 \(9009-42g\)
Ibm power System S924 \(9009-42g\) Firmware
CPEs cpe:2.3:h:ibm:power_system_e1080_\(9080-hex\):-:*:*:*:*:*:*:*
cpe:2.3:h:ibm:power_system_e1180_\(9080-heu\):-:*:*:*:*:*:*:*
cpe:2.3:h:ibm:power_system_e950_\(9040-mr9\):-:*:*:*:*:*:*:*
cpe:2.3:h:ibm:power_system_e980_\(9080-m9s\):-:*:*:*:*:*:*:*
cpe:2.3:h:ibm:power_system_h922_\(9223-22s\):-:*:*:*:*:*:*:*
cpe:2.3:h:ibm:power_system_h924_\(9223-42s\):-:*:*:*:*:*:*:*
cpe:2.3:h:ibm:power_system_s914_\(9009-41g\):-:*:*:*:*:*:*:*
cpe:2.3:h:ibm:power_system_s922_\(9009-22g\):-:*:*:*:*:*:*:*
cpe:2.3:h:ibm:power_system_s924_\(9009-42g\):-:*:*:*:*:*:*:*
cpe:2.3:o:ibm:power_system_e1080_\(9080-hex\)_firmware:*:*:*:*:*:*:*:*
cpe:2.3:o:ibm:power_system_e1180_\(9080-heu\)_firmware:*:*:*:*:*:*:*:*
cpe:2.3:o:ibm:power_system_e1180_\(9080-heu\)_firmware:fw1120.00:*:*:*:*:*:*:*
cpe:2.3:o:ibm:power_system_e950_\(9040-mr9\)_firmware:*:*:*:*:*:*:*:*
cpe:2.3:o:ibm:power_system_e980_\(9080-m9s\)_firmware:*:*:*:*:*:*:*:*
cpe:2.3:o:ibm:power_system_h922_\(9223-22s\)_firmware:*:*:*:*:*:*:*:*
cpe:2.3:o:ibm:power_system_h924_\(9223-42s\)_firmware:*:*:*:*:*:*:*:*
cpe:2.3:o:ibm:power_system_s914_\(9009-41g\)_firmware:*:*:*:*:*:*:*:*
cpe:2.3:o:ibm:power_system_s922_\(9009-22g\)_firmware:*:*:*:*:*:*:*:*
cpe:2.3:o:ibm:power_system_s924_\(9009-42g\)_firmware:*:*:*:*:*:*:*:*
Vendors & Products Ibm power System E1080 \(9080-hex\)
Ibm power System E1080 \(9080-hex\) Firmware
Ibm power System E1180 \(9080-heu\)
Ibm power System E1180 \(9080-heu\) Firmware
Ibm power System E950 \(9040-mr9\)
Ibm power System E950 \(9040-mr9\) Firmware
Ibm power System E980 \(9080-m9s\)
Ibm power System E980 \(9080-m9s\) Firmware
Ibm power System H922 \(9223-22s\)
Ibm power System H922 \(9223-22s\) Firmware
Ibm power System H924 \(9223-42s\)
Ibm power System H924 \(9223-42s\) Firmware
Ibm power System S914 \(9009-41g\)
Ibm power System S914 \(9009-41g\) Firmware
Ibm power System S922 \(9009-22g\)
Ibm power System S922 \(9009-22g\) Firmware
Ibm power System S924 \(9009-42g\)
Ibm power System S924 \(9009-42g\) Firmware
Type Values Removed Values Added
Description IBM Server Firmware FW1120.00, FW1110.00 through FW1110.30, FW1060.00 through FW1060.80, and FW950.00 through FW950.H2 is affected by a vulnerability in the ASMI web interface. An unauthenticated attacker on the management network can cause the ASMI web server to crash with possible memory corruption and generate an error log; hosted partitions are not affected. The ASMI web interface will restart automatically; however, repeated exploitation could result in a sustained loss of access to the ASMI management interface, resulting in an integrity and availability impact. IBM Power Systems Firmware FW1120.00, FW1110.00 through FW1110.30, FW1060.00 through FW1060.80, and FW950.00 through FW950.H2 is affected by a vulnerability in the ASMI web interface. An unauthenticated attacker on the management network can cause the ASMI web server to crash with possible memory corruption and generate an error log; hosted partitions are not affected. The ASMI web interface will restart automatically; however, repeated exploitation could result in a sustained loss of access to the ASMI management interface, resulting in an integrity and availability impact.
Type Values Removed Values Added
Description IBM Server Firmware FW1120.00, FW1110.00 through FW1110.30, FW1060.00 through FW1060.80, and FW950.00 through FW950.H2 is affected by a vulnerability in the ASMI web interface. An unauthenticated attacker on the management network can cause the ASMI web server to crash with possible memory corruption and generate an error log; hosted partitions are not affected. The ASMI web interface will restart automatically; however, repeated exploitation could result in a sustained loss of access to the ASMI management interface, resulting in an integrity and availability impact.
Title Power System Out-of-bounds Read
First Time appeared Ibm
Ibm power Systems Firmware
Weaknesses CWE-125
CPEs cpe:2.3:o:ibm:power_systems_firmware:fw1060.00:*:*:*:*:*:*:*
cpe:2.3:o:ibm:power_systems_firmware:fw1060.80:*:*:*:*:*:*:*
cpe:2.3:o:ibm:power_systems_firmware:fw1110.00:*:*:*:*:*:*:*
cpe:2.3:o:ibm:power_systems_firmware:fw1110.30:*:*:*:*:*:*:*
cpe:2.3:o:ibm:power_systems_firmware:fw1120.00:*:*:*:*:*:*:*
cpe:2.3:o:ibm:power_systems_firmware:fw950.00:*:*:*:*:*:*:*
cpe:2.3:o:ibm:power_systems_firmware:fw950.h2:*:*:*:*:*:*:*
Vendors & Products Ibm
Ibm power Systems Firmware
References
Metrics cvssV3_1

{'score': 7.6, 'vector': 'CVSS:3.1/AV:A/AC:L/PR:N/UI:N/S:U/C:L/I:L/A:H'}