{"dataType": "CVE_RECORD", "dataVersion": "5.2", "cveMetadata": {"cveId": "CVE-2026-118467", "assignerOrgId": "a6d3dc9e-0591-4a13-bce7-0f5b31ff6158", "state": "PUBLISHED", "assignerShortName": "ENISA", "dateReserved": "2026-10-28T08:46:25.411Z", "datePublished": "2026-11-09T11:56:43.635Z", "dateUpdated": "2026-11-12T20:03:31.935Z"}, "containers": {"cna": {"providerMetadata": {"orgId": "a6d3dc9e-0591-4a13-bce7-0f5b31ff6158", "shortName": "ENISA", "dateUpdated": "2026-11-09T11:56:43.635Z"}, "title": "AIS products expose clinical and personal data via logs and telemetry", "problemTypes": [{"descriptions": [{"lang": "en", "cweId": "CWE-532", "description": "CWE-532", "type": "CWE"}]}], "affected": [{"vendor": "CompuGroup Medical", "product": "Infantia", "versions": [{"status": "affected", "version": "0", "lessThanOrEqual": "1.3.1", "versionType": "semver"}], "defaultStatus": "unknown", "packageName": "ImxTracing"}, {"vendor": "CompuGroup Medical", "product": "Profim", "versions": [{"status": "affected", "version": "0", "lessThanOrEqual": "1.3.1", "versionType": "semver"}], "defaultStatus": "unknown", "packageName": "ImxTracing"}, {"vendor": "CompuGroup Medical", "product": "Venere", "versions": [{"status": "affected", "version": "0", "lessThanOrEqual": "1.3.1", "versionType": "semver"}], "defaultStatus": "unknown", "packageName": "ImxTracing"}, {"vendor": "CompuGroup Medical", "product": "Phronesis", "versions": [{"status": "affected", "version": "0", "lessThanOrEqual": "1.3.1", "versionType": "semver"}], "defaultStatus": "unknown", "packageName": "ImxTracing"}, {"vendor": "CompuGroup Medical", "product": "Infantia", "versions": [{"status": "affected", "version": "0", "lessThanOrEqual": "5.1.1", "versionType": "semver"}], "defaultStatus": "unknown", "packageName": "cgm.it.ais.common"}, {"vendor": "CompuGroup Medical", "product": "Profim", "versions": [{"status": "affected", "version": "0", "lessThanOrEqual": "5.1.1", "versionType": "semver"}], "defaultStatus": "unknown", "packageName": "cgm.it.ais.common"}, {"vendor": "CompuGroup Medical", "product": "Venere", "versions": [{"status": "affected", "version": "0", "lessThanOrEqual": "5.1.1", "versionType": "semver"}], "defaultStatus": "unknown", "packageName": "cgm.it.ais.common"}, {"vendor": "CompuGroup Medical", "product": "Phronesis", "versions": [{"status": "affected", "version": "0", "lessThanOrEqual": "5.1.1", "versionType": "semver"}], "defaultStatus": "unknown", "packageName": "cgm.it.ais.common"}], "descriptions": [{"lang": "en", "value": "Shared telemetry and logging components store or transmit patient and doctor identifiers, clinical information, and low-entropy identifiers without adequate pseudonymization or protection.", "supportingMedia": [{"type": "text/html", "base64": false, "value": "<div>Shared telemetry and logging components store or transmit patient and doctor identifiers, clinical information, and low-entropy identifiers without adequate pseudonymization or protection.</div>"}]}], "references": [{"url": "https://www.acn.gov.it/portale/w/rilevate-vulnerabilita-in-prodotti-compugroup-medical"}, {"url": "https://www.cgm.com/ita_it/magazine/articles/comunicati-stampa/piu-sicurezza-per-farmacie-studi-medici-e-pazienti-cgm-italia-risolve-potenziali-vulnerabilita-software-insieme-a-csirt-italia.html"}], "metrics": [{"format": "CVSS", "scenarios": [{"lang": "en", "value": "GENERAL"}], "cvssV4_0": {"attackVector": "LOCAL", "attackComplexity": "LOW", "attackRequirements": "NONE", "privilegesRequired": "LOW", "userInteraction": "NONE", "vulnConfidentialityImpact": "HIGH", "subConfidentialityImpact": "NONE", "vulnIntegrityImpact": "NONE", "subIntegrityImpact": "NONE", "vulnAvailabilityImpact": "NONE", "subAvailabilityImpact": "NONE", "exploitMaturity": "UNREPORTED", "Safety": "NOT_DEFINED", "Automatable": "NOT_DEFINED", "Recovery": "NOT_DEFINED", "valueDensity": "NOT_DEFINED", "vulnerabilityResponseEffort": "NOT_DEFINED", "providerUrgency": "NOT_DEFINED", "version": "4.0", "baseSeverity": "MEDIUM", "baseScore": 4.3, "vectorString": "CVSS:4.0/AV:L/AC:L/AT:N/PR:L/UI:N/VC:H/VI:N/VA:N/SC:N/SI:N/SA:N/E:U"}}], "credits": [{"lang": "en", "value": "Marco Sala", "type": "finder"}, {"lang": "en", "value": "CSIRT-IT", "type": "coordinator"}, {"lang": "en", "value": "ApoCert srl", "type": "finder"}], "x_generator": {"engine": "Vulnogram 1.0.5"}, "source": {"discovery": "UNKNOWN"}}, "adp": [{"metrics": [{"other": {"type": "ssvc", "content": {"timestamp": "2026-11-12T20:03:19.631340Z", "id": "CVE-2026-118467", "options": [{"Exploitation": "none"}, {"Automatable": "no"}, {"Technical Impact": "partial"}], "role": "CISA Coordinator", "version": "2.0.3"}}}], "title": "CISA ADP Vulnrichment", "providerMetadata": {"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0", "shortName": "CISA-ADP", "dateUpdated": "2026-11-12T20:03:31.935Z"}}]}}