CVE-2026-107175

MISP Correlation Engine Fails to Refresh When Event Distribution or Sharing Group Changes

Published Oct 7, 2026 CVSS 4.0 · 5.3 Medium EPSS < 1% KEV · Not listed
Description
MISP contains a defect in its event save workflow that prevents the correlation engine from recalculating correlations when an event's distribution level or sharing group is modified.

When a user edits an existing event and changes its distribution or sharing_group_id, the internal before-save hook stored the incoming (new) data rather than the previously persisted values. As a result, the after-save comparison that determines whether a correlation refresh is needed never detected the change, and stale correlations persisted.

Security impact:

- Stale correlations may continue to expose event data to users in a broader sharing group after the event has been moved to a more restrictive group, resulting in unintended information disclosure.

- Conversely, newly relevant correlations may not appear after a distribution widening, degrading the completeness of threat intelligence sharing.

Preconditions:

- An authenticated user with write access to at least one MISP event.

- The user modifies the event's distribution or sharing_group_id field.

Affected versions: <2.5.48

Remediation

Vendor Solution

The fix ensures that the before-save hook retrieves the previously persisted distribution and sharing_group_id values from the database for existing events, rather than capturing the incoming (new) data. This allows the after-save logic to correctly detect when these fields have changed and trigger a correlation refresh, ensuring access boundaries on correlated data are enforced promptly.

Tracking

Sign in to view the affected projects.

Advisories

No advisories available
History
Type Values Removed Values Added
Metrics ssvc

{'options': {'Automatable': 'no', 'Exploitation': 'none', 'Technical Impact': 'partial'}, 'version': '2.0.3'}

Type Values Removed Values Added
Description MISP contains a defect in its event save workflow that prevents the correlation engine from recalculating correlations when an event's distribution level or sharing group is modified. When a user edits an existing event and changes its distribution or sharing_group_id, the internal before-save hook stored the incoming (new) data rather than the previously persisted values. As a result, the after-save comparison that determines whether a correlation refresh is needed never detected the change, and stale correlations persisted. Security impact: - Stale correlations may continue to expose event data to users in a broader sharing group after the event has been moved to a more restrictive group, resulting in unintended information disclosure. - Conversely, newly relevant correlations may not appear after a distribution widening, degrading the completeness of threat intelligence sharing. Preconditions: - An authenticated user with write access to at least one MISP event. - The user modifies the event's distribution or sharing_group_id field. Affected versions: <2.5.48
Title MISP Correlation Engine Fails to Refresh When Event Distribution or Sharing Group Changes
First Time appeared Misp
Misp misp
Weaknesses CWE-284
CWE-665
CPEs cpe:2.3:a:misp:misp:*:*:*:*:*:*:*:*
Vendors & Products Misp
Misp misp
References
Metrics cvssV4_0

{'score': 5.3, 'vector': 'CVSS:4.0/AV:N/AC:L/AT:N/PR:L/UI:N/VC:N/VI:N/VA:N/SC:L/SI:N/SA:N'}

Weaknesses

Sources

Status
PUBLISHED
Assigner
CIRCL
Published
Updated
Oct 7, 2026, 2:40 PM
Reserved
Oct 7, 2026, 12:38 PM
Status
Deferred
Published
Oct 7, 2026, 1:17 PM
Modified
Oct 7, 2026, 3:17 PM