CVE-2025-59702

Published Dec 2, 2025 CVSS 3.1 · 7.2 High EPSS < 1% KEV · Not listed
Description
Entrust nShield Connect XC, nShield 5c, and nShield HSMi through 13.6.11, or 13.7 (patched in 13.6.12 (LTS) and 13.9.0 (STS)), allow a physically proximate attacker with elevated privileges to falsify tamper events by accessing internal components.

Remediation

No solution or workaround provided in the CVE record

Tracking

Sign in to view the affected projects.

Advisories

No advisories available
History
Type Values Removed Values Added
Description Entrust nShield Connect XC, nShield 5c, and nShield HSMi through 13.6.11, or 13.7, allow a physically proximate attacker with elevated privileges to falsify tamper events by accessing internal components. Entrust nShield Connect XC, nShield 5c, and nShield HSMi through 13.6.11, or 13.7 (patched in 13.6.12 (LTS) and 13.9.0 (STS)), allow a physically proximate attacker with elevated privileges to falsify tamper events by accessing internal components.
References
Type Values Removed Values Added
First Time appeared Entrust nshield 5c Firmware
Entrust nshield Connect Xc Base
Entrust nshield Connect Xc Base Firmware
Entrust nshield Connect Xc High
Entrust nshield Connect Xc High Firmware
Entrust nshield Connect Xc Mid
Entrust nshield Connect Xc Mid Firmware
Entrust nshield Hsmi Firmware
CPEs cpe:2.3:h:entrust:nshield_5c:-:*:*:*:*:*:*:*
cpe:2.3:h:entrust:nshield_connect_xc_base:-:*:*:*:*:*:*:*
cpe:2.3:h:entrust:nshield_connect_xc_high:-:*:*:*:*:*:*:*
cpe:2.3:h:entrust:nshield_connect_xc_mid:-:*:*:*:*:*:*:*
cpe:2.3:h:entrust:nshield_hsmi:-:*:*:*:*:*:*:*
cpe:2.3:o:entrust:nshield_5c_firmware:*:*:*:*:*:*:*:*
cpe:2.3:o:entrust:nshield_connect_xc_base_firmware:*:*:*:*:*:*:*:*
cpe:2.3:o:entrust:nshield_connect_xc_high_firmware:*:*:*:*:*:*:*:*
cpe:2.3:o:entrust:nshield_connect_xc_mid_firmware:*:*:*:*:*:*:*:*
cpe:2.3:o:entrust:nshield_hsmi_firmware:*:*:*:*:*:*:*:*
Vendors & Products Entrust nshield 5c Firmware
Entrust nshield Connect Xc Base
Entrust nshield Connect Xc Base Firmware
Entrust nshield Connect Xc High
Entrust nshield Connect Xc High Firmware
Entrust nshield Connect Xc Mid
Entrust nshield Connect Xc Mid Firmware
Entrust nshield Hsmi Firmware
Type Values Removed Values Added
First Time appeared Entrust
Entrust nshield 5c
Entrust nshield Connect Xc
Entrust nshield Hsmi
Vendors & Products Entrust
Entrust nshield 5c
Entrust nshield Connect Xc
Entrust nshield Hsmi
Type Values Removed Values Added
Weaknesses CWE-203
CWE-284
Metrics cvssV3_1

{'score': 7.2, 'vector': 'CVSS:3.1/AV:P/AC:L/PR:H/UI:N/S:C/C:H/I:H/A:H'}

ssvc

{'options': {'Automatable': 'no', 'Exploitation': 'poc', 'Technical Impact': 'total'}, 'version': '2.0.3'}

Type Values Removed Values Added
Description Entrust nShield Connect XC, nShield 5c, and nShield HSMi through 13.6.11, or 13.7, allow a physically proximate attacker with elevated privileges to falsify tamper events by accessing internal components.
References