CVE-2025-59103

Weak Default Passwords for SSH Access in dormakaba access manager

Published Jan 26, 2026 CVSS 4.0 · 9.2 Critical EPSS < 1% KEV · Not listed
Description
The Access Manager 92xx in hardware revision K7 is based on Linux instead of Windows CE embedded in older hardware revisions. In this new hardware revision it was noticed that an SSH service is exposed on port 22. By analyzing the firmware of the devices, it was noticed that there are two users with hardcoded and weak passwords that can be used to access the devices via SSH. The passwords can be also guessed very easily. The password of at least one user is set to a random value after the first deployment, with the restriction that the password is only randomized if the configured date is prior to 2022. Therefore, under certain circumstances, the passwords are not randomized. For example, if the clock is never set on the device, the battery of the clock module has been changed, the Access Manager has been factory reset and has not received a time yet.

Remediation

Vendor Solution

It is recommended to update the Access Manager 92xx K7 at least to the Firmware BAME 05.01.88 RA.

Tracking

Sign in to view the affected projects.

Advisories

No advisories available
History
Type Values Removed Values Added
First Time appeared Dormakaba
Dormakaba access Manager
Vendors & Products Dormakaba
Dormakaba access Manager
Type Values Removed Values Added
Metrics ssvc

{'options': {'Automatable': 'yes', 'Exploitation': 'none', 'Technical Impact': 'total'}, 'version': '2.0.3'}

Type Values Removed Values Added
Description The Access Manager 92xx in hardware revision K7 is based on Linux instead of Windows CE embedded in older hardware revisions. In this new hardware revision it was noticed that an SSH service is exposed on port 22. By analyzing the firmware of the devices, it was noticed that there are two users with hardcoded and weak passwords that can be used to access the devices via SSH. The passwords can be also guessed very easily. The password of at least one user is set to a random value after the first deployment, with the restriction that the password is only randomized if the configured date is prior to 2022. Therefore, under certain circumstances, the passwords are not randomized. For example, if the clock is never set on the device, the battery of the clock module has been changed, the Access Manager has been factory reset and has not received a time yet.
Title Weak Default Passwords for SSH Access in dormakaba access manager
Weaknesses CWE-1391
References
Metrics cvssV4_0

{'score': 9.2, 'vector': 'CVSS:4.0/AV:N/AC:L/AT:P/PR:N/UI:N/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N'}

Weaknesses

Sources

Status
PUBLISHED
Assigner
SEC-VLab
Published
Updated
Jan 26, 2026, 3:13 PM
Reserved
Sep 9, 2025, 7:53 AM
Status
Deferred
Published
Jan 26, 2026, 10:16 AM
Modified
Jun 17, 2026, 9:45 AM