EG4 Electronics EG4 Inverters Cleartext Transmission of Sensitive Information
Default status is the baseline for the product, each version can override it (e.g. patched versions marked unaffected).
| Vendor | Product | Default status | Versions | ||||||
|---|---|---|---|---|---|---|---|---|---|
| EG4 Electronics | EG4 12kPV | unaffected |
|
||||||
| EG4 Electronics | EG4 18kPV | unaffected |
|
||||||
| EG4 Electronics | EG4 Flex 21 | unaffected |
|
||||||
| EG4 Electronics | EG4 Flex 18 | unaffected |
|
||||||
| EG4 Electronics | EG4 6000XP | unaffected |
|
||||||
| EG4 Electronics | EG4 12000XP | unaffected |
|
||||||
| EG4 Electronics | EG4 GridBoss | unaffected |
|
No data.
No data.
| Vendor | Product | Versions |
|---|---|---|
| Eg4 Electronics | Eg4 12000xp | — |
| Eg4 Electronics | Eg4 12kpv | — |
| Eg4 Electronics | Eg4 18kpv | — |
| Eg4 Electronics | Eg4 6000xp | — |
| Eg4 Electronics | Eg4 Flex 18 | — |
| Eg4 Electronics | Eg4 Flex 21 | — |
| Eg4 Electronics | Eg4 Gridboss | — |
Vendor Workaround
EG4 has acknowledged the vulnerabilities and is actively working on a fix, including new hardware expected to release by October 15, 2025. Until then, EG4 will actively monitor all installed systems and work with affected users on a case-by-case basis if anomalies are observed. For more information, contact EG4. https://eg4electronics.com/contact/
| Source | ID | Title |
|---|---|---|
EUVD |
EUVD-2025-23994 | The MOD3 command traffic between the monitoring application and the inverter is transmitted in plaintext without encryption or obfuscation. This vulnerability may allow an attacker with access to a local network to intercept, manipulate, replay, or forge critical data, including read/write operations for voltage, current, and power configuration, operational status, alarms, telemetry, system reset, or inverter control commands, potentially disrupting power generation or reconfiguring inverter settings. |
No CVSS v3.0
No CVSS v2
This CVE is not in the KEV list.
Exploit prediction score: < 1% (0.091% probability within 30 days)
| Type | Values Removed | Values Added |
|---|---|---|
| References |
|
| Type | Values Removed | Values Added |
|---|---|---|
| First Time appeared |
Eg4 Electronics
Eg4 Electronics eg4 12000xp Eg4 Electronics eg4 12kpv Eg4 Electronics eg4 18kpv Eg4 Electronics eg4 6000xp Eg4 Electronics eg4 Flex 18 Eg4 Electronics eg4 Flex 21 Eg4 Electronics eg4 Gridboss |
|
| Vendors & Products |
Eg4 Electronics
Eg4 Electronics eg4 12000xp Eg4 Electronics eg4 12kpv Eg4 Electronics eg4 18kpv Eg4 Electronics eg4 6000xp Eg4 Electronics eg4 Flex 18 Eg4 Electronics eg4 Flex 21 Eg4 Electronics eg4 Gridboss |
| Type | Values Removed | Values Added |
|---|---|---|
| Metrics |
ssvc
|
| Type | Values Removed | Values Added |
|---|---|---|
| Description | The MOD3 command traffic between the monitoring application and the inverter is transmitted in plaintext without encryption or obfuscation. This vulnerability may allow an attacker with access to a local network to intercept, manipulate, replay, or forge critical data, including read/write operations for voltage, current, and power configuration, operational status, alarms, telemetry, system reset, or inverter control commands, potentially disrupting power generation or reconfiguring inverter settings. | |
| Title | EG4 Electronics EG4 Inverters Cleartext Transmission of Sensitive Information | |
| Weaknesses | CWE-319 | |
| References |
| |
| Metrics |
cvssV3_1
|