CVE-2025-46625

Published May 1, 2025 CVSS 3.1 · 8.8 High EPSS < 1% KEV · Not listed
Description
Lack of input validation/sanitization in the 'setLanCfg' API endpoint in httpd in the Tenda RX2 Pro 16.03.30.14 allows a remote attacker that is authorized to the web management portal to gain root shell access to the device by sending a crafted web request. This is persistent because the command injection is saved in the configuration of the device.

Remediation

No solution or workaround provided in the CVE record

Tracking

Sign in to view the affected projects.

Advisories

Source ID Title
EUVD EUVD EUVD-2025-13260 Lack of input validation/sanitization in the 'setLanCfg' API endpoint in httpd in the Tenda RX2 Pro 16.03.30.14 allows a remote attacker that is authorized to the web management portal to gain root shell access to the device by sending a crafted web request. This is persistent because the command injection is saved in the configuration of the device.
History
Type Values Removed Values Added
First Time appeared Tenda
Tenda rx2 Pro
Tenda rx2 Pro Firmware
CPEs cpe:2.3:h:tenda:rx2_pro:-:*:*:*:*:*:*:*
cpe:2.3:o:tenda:rx2_pro_firmware:16.03.30.14:*:*:*:*:*:*:*
Vendors & Products Tenda
Tenda rx2 Pro
Tenda rx2 Pro Firmware
Type Values Removed Values Added
Metrics cvssV3_1

{'score': 6.3, 'vector': 'CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:L/I:L/A:L'}

cvssV3_1

{'score': 8.8, 'vector': 'CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H'}

Type Values Removed Values Added
Weaknesses CWE-77
Metrics cvssV3_1

{'score': 6.3, 'vector': 'CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:L/I:L/A:L'}

ssvc

{'options': {'Automatable': 'no', 'Exploitation': 'none', 'Technical Impact': 'total'}, 'version': '2.0.3'}

Type Values Removed Values Added
Description Lack of input validation/sanitization in the 'setLanCfg' API endpoint in httpd in the Tenda RX2 Pro 16.03.30.14 allows a remote attacker that is authorized to the web management portal to gain root shell access to the device by sending a crafted web request. This is persistent because the command injection is saved in the configuration of the device.
References
Weaknesses

Sources

Status
PUBLISHED
Assigner
mitre
Published
Updated
May 2, 2025, 1:06 PM
Reserved
Apr 26, 2025, 12:00 AM
Status
Analyzed
Published
May 1, 2025, 8:15 PM
Modified
Jun 17, 2026, 9:26 AM