CVE-2025-4340

D-Link DIR-890L/DIR-806A1 soap.cgi sub_175C8 command injection

Published May 6, 2025 CVSS 4.0 · 5.3 Medium EPSS 5.3% KEV · Not listed
Description
A vulnerability classified as critical has been found in D-Link DIR-890L and DIR-806A1 up to 100CNb11/108B03. Affected is the function sub_175C8 of the file /htdocs/soap.cgi. The manipulation leads to command injection. It is possible to launch the attack remotely. The exploit has been disclosed to the public and may be used. This vulnerability only affects products that are no longer supported by the maintainer.

Remediation

No solution or workaround provided in the CVE record

Tracking

Sign in to view the affected projects.

Advisories

Source ID Title
EUVD EUVD EUVD-2025-13558 A vulnerability classified as critical has been found in D-Link DIR-890L and DIR-806A1 up to 100CNb11/108B03. Affected is the function sub_175C8 of the file /htdocs/soap.cgi. The manipulation leads to command injection. It is possible to launch the attack remotely. The exploit has been disclosed to the public and may be used. This vulnerability only affects products that are no longer supported by the maintainer.
History
Type Values Removed Values Added
Metrics epss

{'score': 0.00126}

epss

{'score': 0.00109}

Type Values Removed Values Added
First Time appeared Dlink
Dlink dir-806
Dlink dir-806 Firmware
Dlink dir-890l
Dlink dir-890l Firmware
CPEs cpe:2.3:h:dlink:dir-806:a1:*:*:*:*:*:*:*
cpe:2.3:h:dlink:dir-890l:a1:*:*:*:*:*:*:*
cpe:2.3:o:dlink:dir-806_firmware:*:*:*:*:*:*:*:*
cpe:2.3:o:dlink:dir-890l_firmware:*:*:*:*:*:*:*:*
Vendors & Products Dlink
Dlink dir-806
Dlink dir-806 Firmware
Dlink dir-890l
Dlink dir-890l Firmware
Type Values Removed Values Added
Metrics ssvc

{'options': {'Automatable': 'no', 'Exploitation': 'poc', 'Technical Impact': 'partial'}, 'version': '2.0.3'}

Type Values Removed Values Added
Description A vulnerability classified as critical has been found in D-Link DIR-890L and DIR-806A1 up to 100CNb11/108B03. Affected is the function sub_175C8 of the file /htdocs/soap.cgi. The manipulation leads to command injection. It is possible to launch the attack remotely. The exploit has been disclosed to the public and may be used. This vulnerability only affects products that are no longer supported by the maintainer.
Title D-Link DIR-890L/DIR-806A1 soap.cgi sub_175C8 command injection
Weaknesses CWE-74
CWE-77
References
Metrics cvssV2_0

{'score': 6.5, 'vector': 'AV:N/AC:L/Au:S/C:P/I:P/A:P'}

cvssV3_0

{'score': 6.3, 'vector': 'CVSS:3.0/AV:N/AC:L/PR:L/UI:N/S:U/C:L/I:L/A:L'}

cvssV3_1

{'score': 6.3, 'vector': 'CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:L/I:L/A:L'}

cvssV4_0

{'score': 5.3, 'vector': 'CVSS:4.0/AV:N/AC:L/AT:N/PR:L/UI:N/VC:L/VI:L/VA:L/SC:N/SI:N/SA:N'}

Weaknesses

Sources

Status
PUBLISHED
Assigner
VulDB
Published
Updated
May 6, 2025, 1:53 PM
Reserved
May 5, 2025, 4:51 PM
Status
Analyzed
Published
May 6, 2025, 8:15 AM
Modified
Jun 17, 2026, 9:33 AM