CVE-2025-41738

CODESYS Control - Invalid type usage in visualization

Published Dec 1, 2025 CVSS 3.1 · 7.5 High EPSS < 1% KEV · Not listed
Description
An unauthenticated remote attacker may cause the visualisation server of the CODESYS Control runtime system to access a resource with a pointer of wrong type, potentially leading to a denial-of-service (DoS) condition.

Remediation

No solution or workaround provided in the CVE record

Tracking

Sign in to view the affected projects.

Advisories

No advisories available
History
Type Values Removed Values Added
First Time appeared Codesys control For Empc-a\/imx6 Sl
Codesys control Rte Sl
Codesys control Rte Sl \(for Beckhoff Cx\)
Codesys control Win Sl
Codesys hmi Sl
CPEs cpe:2.3:a:codesys:control_for_beaglebone_sl:*:*:*:*:*:*:*:*
cpe:2.3:a:codesys:control_for_empc-a\/imx6_sl:*:*:*:*:*:*:*:*
cpe:2.3:a:codesys:control_for_iot2000_sl:*:*:*:*:*:*:*:*
cpe:2.3:a:codesys:control_for_linux_arm_sl:*:*:*:*:*:*:*:*
cpe:2.3:a:codesys:control_for_linux_sl:*:*:*:*:*:*:*:*
cpe:2.3:a:codesys:control_for_pfc100_sl:*:*:*:*:*:*:*:*
cpe:2.3:a:codesys:control_for_pfc200_sl:*:*:*:*:*:*:*:*
cpe:2.3:a:codesys:control_for_plcnext_sl:*:*:*:*:*:*:*:*
cpe:2.3:a:codesys:control_for_raspberry_pi_sl:*:*:*:*:*:*:*:*
cpe:2.3:a:codesys:control_for_wago_touch_panels_600_sl:*:*:*:*:*:*:*:*
cpe:2.3:a:codesys:control_rte_sl:*:*:*:*:*:*:*:*
cpe:2.3:a:codesys:control_rte_sl_\(for_beckhoff_cx\):*:*:*:*:*:*:*:*
cpe:2.3:a:codesys:control_win_sl:*:*:*:*:*:*:*:*
cpe:2.3:a:codesys:hmi_sl:*:*:*:*:*:*:*:*
cpe:2.3:a:codesys:remote_target_visu:*:*:*:*:*:*:*:*
cpe:2.3:a:codesys:runtime_toolkit:*:*:*:*:*:*:*:*
cpe:2.3:a:codesys:virtual_control_sl:*:*:*:*:*:*:*:*
Vendors & Products Codesys control For Empc-a\/imx6 Sl
Codesys control Rte Sl
Codesys control Rte Sl \(for Beckhoff Cx\)
Codesys control Win Sl
Codesys hmi Sl
Type Values Removed Values Added
First Time appeared Codesys
Codesys control For Beaglebone Sl
Codesys control For Empc-a/imx6 Sl
Codesys control For Iot2000 Sl
Codesys control For Linux Arm Sl
Codesys control For Linux Sl
Codesys control For Pfc100 Sl
Codesys control For Pfc200 Sl
Codesys control For Plcnext Sl
Codesys control For Raspberry Pi Sl
Codesys control For Wago Touch Panels 600 Sl
Codesys control Rte
Codesys control Rte (sl)
Codesys control Win (sl)
Codesys hmi (sl)
Codesys remote Target Visu
Codesys runtime Toolkit
Codesys virtual Control Sl
Vendors & Products Codesys
Codesys control For Beaglebone Sl
Codesys control For Empc-a/imx6 Sl
Codesys control For Iot2000 Sl
Codesys control For Linux Arm Sl
Codesys control For Linux Sl
Codesys control For Pfc100 Sl
Codesys control For Pfc200 Sl
Codesys control For Plcnext Sl
Codesys control For Raspberry Pi Sl
Codesys control For Wago Touch Panels 600 Sl
Codesys control Rte
Codesys control Rte (sl)
Codesys control Win (sl)
Codesys hmi (sl)
Codesys remote Target Visu
Codesys runtime Toolkit
Codesys virtual Control Sl
Type Values Removed Values Added
Metrics ssvc

{'options': {'Automatable': 'yes', 'Exploitation': 'none', 'Technical Impact': 'partial'}, 'version': '2.0.3'}

Type Values Removed Values Added
Description An unauthenticated remote attacker may cause the visualisation server of the CODESYS Control runtime system to access a resource with a pointer of wrong type, potentially leading to a denial-of-service (DoS) condition.
Title CODESYS Control - Invalid type usage in visualization
Weaknesses CWE-843
References
Metrics cvssV3_1

{'score': 7.5, 'vector': 'CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H'}