CVE-2025-41108

Improper Authentication vulnerability in Ghost Robotics' Vision 60

Published Oct 22, 2025 CVSS 4.0 · 9.2 Critical EPSS < 1% KEV · Not listed
Description
The communication protocol implemented in Ghost Robotics Vision 60 v0.27.2 could allow an attacker to send commands to the robot from an external attack station, impersonating the control station (tablet) and gaining unauthorised full control of the robot. The absence of encryption and authentication mechanisms in the communication protocol allows an attacker to capture legitimate traffic between the robot and the controller, replicate it, and send any valid command to the robot from any attacking computer or device. The communication protocol used in this interface is based on MAVLink, a widely documented protocol, which increases the likelihood of attack. There are two methods for connecting to the robot remotely: Wi-Fi and 4G/LTE.

Remediation

No solution or workaround provided in the CVE record

Tracking

Sign in to view the affected projects.

Advisories

No advisories available
History
Type Values Removed Values Added
First Time appeared Ghostrobotics
Ghostrobotics vision 60
Ghostrobotics vision 60 Firmware
Weaknesses NVD-CWE-noinfo
CPEs cpe:2.3:h:ghostrobotics:vision_60:-:*:*:*:*:*:*:*
cpe:2.3:o:ghostrobotics:vision_60_firmware:0.27.2:*:*:*:*:*:*:*
Vendors & Products Ghostrobotics
Ghostrobotics vision 60
Ghostrobotics vision 60 Firmware
Metrics cvssV3_1

{'score': 9.8, 'vector': 'CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H'}

Type Values Removed Values Added
First Time appeared Ghost Robotics
Ghost Robotics vision 60
Vendors & Products Ghost Robotics
Ghost Robotics vision 60
Type Values Removed Values Added
Metrics ssvc

{'options': {'Automatable': 'no', 'Exploitation': 'none', 'Technical Impact': 'partial'}, 'version': '2.0.3'}

Type Values Removed Values Added
Description The communication protocol implemented in Ghost Robotics Vision 60 v0.27.2 could allow an attacker to send commands to the robot from an external attack station, impersonating the control station (tablet) and gaining unauthorised full control of the robot. The absence of encryption and authentication mechanisms in the communication protocol allows an attacker to capture legitimate traffic between the robot and the controller, replicate it, and send any valid command to the robot from any attacking computer or device. The communication protocol used in this interface is based on MAVLink, a widely documented protocol, which increases the likelihood of attack. There are two methods for connecting to the robot remotely: Wi-Fi and 4G/LTE.
Title Improper Authentication vulnerability in Ghost Robotics' Vision 60
Weaknesses CWE-287
References
Metrics cvssV4_0

{'score': 9.2, 'vector': 'CVSS:4.0/AV:N/AC:L/AT:P/PR:N/UI:N/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N'}