Improper Client‑Certificate Validation Enables Man‑in‑the‑Middle Attacks in Siemens Software Products
Default status is the baseline for the product, each version can override it (e.g. patched versions marked unaffected).
| Vendor | Product | Default status | Versions | ||||||
|---|---|---|---|---|---|---|---|---|---|
| Siemens | Siemens Software Center | unknown |
|
||||||
| Siemens | Simcenter 3D | unknown |
|
||||||
| Siemens | Simcenter Femap | unknown |
|
||||||
| Siemens | Simcenter STAR-CCM+ | unknown |
|
||||||
| Siemens | Solid Edge SE2025 | unknown |
|
||||||
| Siemens | Solid Edge SE2026 | unknown |
|
||||||
| Siemens | Tecnomatix Plant Simulation | unknown |
|
Configuration 1 [-]
|
No data.
| Vendor | Product | Versions | ||||||||
|---|---|---|---|---|---|---|---|---|---|---|
| Siemens | Simcenter 3d |
|
||||||||
| Siemens | Simcenter Femap |
|
||||||||
| Siemens | Simcenter Star-ccm\+ |
|
||||||||
| Siemens | Software Center |
|
||||||||
| Siemens | Solid Edge Se2025 |
|
||||||||
| Siemens | Solid Edge Se2026 |
|
||||||||
| Siemens | Tecnomatix Plant Simulation |
|
No CVSS v3.0
No CVSS v2
This CVE is not in the KEV list.
Exploit prediction score: < 1% (0.140% probability within 30 days)
| Type | Values Removed | Values Added |
|---|---|---|
| Title | Improper Client‑Certificate Validation Enables Man‑in‑the‑Middle Attacks in Siemens Software Products |
| Type | Values Removed | Values Added |
|---|---|---|
| First Time appeared |
Siemens
Siemens simcenter 3d Siemens simcenter Femap Siemens simcenter Star-ccm\+ Siemens software Center Siemens solid Edge Se2025 Siemens solid Edge Se2026 Siemens tecnomatix Plant Simulation |
|
| Vendors & Products |
Siemens
Siemens simcenter 3d Siemens simcenter Femap Siemens simcenter Star-ccm\+ Siemens software Center Siemens solid Edge Se2025 Siemens solid Edge Se2026 Siemens tecnomatix Plant Simulation |
| Type | Values Removed | Values Added |
|---|---|---|
| Metrics |
ssvc
|
| Type | Values Removed | Values Added |
|---|---|---|
| Description | A vulnerability has been identified in Siemens Software Center (All versions < V3.5.8.2), Simcenter 3D (All versions < V2506.6000), Simcenter Femap (All versions < V2506.0002), Simcenter STAR-CCM+ (All versions < V2602), Solid Edge SE2025 (All versions < V225.0 Update 13), Solid Edge SE2026 (All versions < V226.0 Update 04), Tecnomatix Plant Simulation (All versions < V2504.0008). Affected applications do not properly validate client certificates to connect to Analytics Service endpoint. This could allow an unauthenticated remote attacker to perform man in the middle attacks. | |
| Weaknesses | CWE-295 | |
| References |
| |
| Metrics |
cvssV3_1
|