CVE-2025-34035

EnGenius EnShare IoT Gigabit Cloud Service Command Injection

Published Jun 24, 2025 CVSS 4.0 · 10 Critical EPSS 24.8% KEV · Not listed
Description
An OS command injection vulnerability exists in EnGenius EnShare Cloud Service version 1.4.11 and earlier. The usbinteract.cgi script fails to properly sanitize user input passed to the path parameter, allowing unauthenticated remote attackers to inject arbitrary shell commands. The injected commands are executed with root privileges, leading to full system compromise. Exploitation evidence was observed by the Shadowserver Foundation on 2024-12-05 UTC.

Remediation

No solution or workaround provided in the CVE record

Tracking

Sign in to view the affected projects.

Advisories

No advisories available
History
Type Values Removed Values Added
Description An OS command injection vulnerability exists in EnGenius EnShare Cloud Service version 1.4.11 and earlier. The usbinteract.cgi script fails to properly sanitize user input passed to the path parameter, allowing unauthenticated remote attackers to inject arbitrary shell commands. The injected commands are executed with root privileges, leading to full system compromise. Exploitation evidence was observed by the Shadowserver Foundation on 2025-08-27 UTC. An OS command injection vulnerability exists in EnGenius EnShare Cloud Service version 1.4.11 and earlier. The usbinteract.cgi script fails to properly sanitize user input passed to the path parameter, allowing unauthenticated remote attackers to inject arbitrary shell commands. The injected commands are executed with root privileges, leading to full system compromise. Exploitation evidence was observed by the Shadowserver Foundation on 2024-12-05 UTC.
Type Values Removed Values Added
Weaknesses CWE-20
Type Values Removed Values Added
Description An OS command injection vulnerability exists in EnGenius EnShare Cloud Service version 1.4.11 and earlier. The usbinteract.cgi script fails to properly sanitize user input passed to the path parameter, allowing unauthenticated remote attackers to inject arbitrary shell commands. The injected commands are executed with root privileges, leading to full system compromise. An OS command injection vulnerability exists in EnGenius EnShare Cloud Service version 1.4.11 and earlier. The usbinteract.cgi script fails to properly sanitize user input passed to the path parameter, allowing unauthenticated remote attackers to inject arbitrary shell commands. The injected commands are executed with root privileges, leading to full system compromise. Exploitation evidence was observed by the Shadowserver Foundation on 2025-08-27 UTC.
Type Values Removed Values Added
First Time appeared Engeniustech
Engeniustech epg5000
Engeniustech epg5000 Firmware
Engeniustech esr1200
Engeniustech esr1200 Firmware
Engeniustech esr1750
Engeniustech esr1750 Firmware
Engeniustech esr300
Engeniustech esr300 Firmware
Engeniustech esr350
Engeniustech esr350 Firmware
Engeniustech esr600
Engeniustech esr600 Firmware
Engeniustech esr900
Engeniustech esr900 Firmware
CPEs cpe:2.3:h:engeniustech:epg5000:-:*:*:*:*:*:*:*
cpe:2.3:h:engeniustech:esr1200:-:*:*:*:*:*:*:*
cpe:2.3:h:engeniustech:esr1750:-:*:*:*:*:*:*:*
cpe:2.3:h:engeniustech:esr300:-:*:*:*:*:*:*:*
cpe:2.3:h:engeniustech:esr350:-:*:*:*:*:*:*:*
cpe:2.3:h:engeniustech:esr600:-:*:*:*:*:*:*:*
cpe:2.3:h:engeniustech:esr900:-:*:*:*:*:*:*:*
cpe:2.3:o:engeniustech:epg5000_firmware:1.2.0:*:*:*:*:*:*:*
cpe:2.3:o:engeniustech:epg5000_firmware:1.3.0:*:*:*:*:*:*:*
cpe:2.3:o:engeniustech:epg5000_firmware:1.3.2:*:*:*:*:*:*:*
cpe:2.3:o:engeniustech:epg5000_firmware:1.3.3.17:*:*:*:*:*:*:*
cpe:2.3:o:engeniustech:epg5000_firmware:1.3.3:*:*:*:*:*:*:*
cpe:2.3:o:engeniustech:epg5000_firmware:1.3.7.20:*:*:*:*:*:*:*
cpe:2.3:o:engeniustech:epg5000_firmware:1.3.9.21:*:*:*:*:*:*:*
cpe:2.3:o:engeniustech:esr1200_firmware:1.1.0:*:*:*:*:*:*:*
cpe:2.3:o:engeniustech:esr1200_firmware:1.3.1.34:*:*:*:*:*:*:*
cpe:2.3:o:engeniustech:esr1200_firmware:1.4.1:*:*:*:*:*:*:*
cpe:2.3:o:engeniustech:esr1200_firmware:1.4.3:*:*:*:*:*:*:*
cpe:2.3:o:engeniustech:esr1200_firmware:1.4.5:*:*:*:*:*:*:*
cpe:2.3:o:engeniustech:esr1750_firmware:1.1.0:*:*:*:*:*:*:*
cpe:2.3:o:engeniustech:esr1750_firmware:1.2.2.27:*:*:*:*:*:*:*
cpe:2.3:o:engeniustech:esr1750_firmware:1.3.0:*:*:*:*:*:*:*
cpe:2.3:o:engeniustech:esr1750_firmware:1.3.1.34:*:*:*:*:*:*:*
cpe:2.3:o:engeniustech:esr1750_firmware:1.4.0:*:*:*:*:*:*:*
cpe:2.3:o:engeniustech:esr1750_firmware:1.4.1:*:*:*:*:*:*:*
cpe:2.3:o:engeniustech:esr1750_firmware:1.4.3:*:*:*:*:*:*:*
cpe:2.3:o:engeniustech:esr1750_firmware:1.4.5:*:*:*:*:*:*:*
cpe:2.3:o:engeniustech:esr300_firmware:1.1.0.28:*:*:*:*:*:*:*
cpe:2.3:o:engeniustech:esr300_firmware:1.3.1.42:*:*:*:*:*:*:*
cpe:2.3:o:engeniustech:esr300_firmware:1.4.0:*:*:*:*:*:*:*
cpe:2.3:o:engeniustech:esr300_firmware:1.4.1.28:*:*:*:*:*:*:*
cpe:2.3:o:engeniustech:esr300_firmware:1.4.2:*:*:*:*:*:*:*
cpe:2.3:o:engeniustech:esr300_firmware:1.4.7:*:*:*:*:*:*:*
cpe:2.3:o:engeniustech:esr300_firmware:1.4.9:*:*:*:*:*:*:*
cpe:2.3:o:engeniustech:esr350_firmware:1.1.0.29:*:*:*:*:*:*:*
cpe:2.3:o:engeniustech:esr350_firmware:1.3.1.41:*:*:*:*:*:*:*
cpe:2.3:o:engeniustech:esr350_firmware:1.4.0:*:*:*:*:*:*:*
cpe:2.3:o:engeniustech:esr350_firmware:1.4.11:*:*:*:*:*:*:*
cpe:2.3:o:engeniustech:esr350_firmware:1.4.2:*:*:*:*:*:*:*
cpe:2.3:o:engeniustech:esr350_firmware:1.4.5:*:*:*:*:*:*:*
cpe:2.3:o:engeniustech:esr350_firmware:1.4.9:*:*:*:*:*:*:*
cpe:2.3:o:engeniustech:esr600_firmware:1.1.0.50:*:*:*:*:*:*:*
cpe:2.3:o:engeniustech:esr600_firmware:1.2.1.46:*:*:*:*:*:*:*
cpe:2.3:o:engeniustech:esr600_firmware:1.3.1.63:*:*:*:*:*:*:*
cpe:2.3:o:engeniustech:esr600_firmware:1.4.0.23:*:*:*:*:*:*:*
cpe:2.3:o:engeniustech:esr600_firmware:1.4.11:*:*:*:*:*:*:*
cpe:2.3:o:engeniustech:esr600_firmware:1.4.1:*:*:*:*:*:*:*
cpe:2.3:o:engeniustech:esr600_firmware:1.4.2:*:*:*:*:*:*:*
cpe:2.3:o:engeniustech:esr600_firmware:1.4.3:*:*:*:*:*:*:*
cpe:2.3:o:engeniustech:esr600_firmware:1.4.5:*:*:*:*:*:*:*
cpe:2.3:o:engeniustech:esr600_firmware:1.4.9:*:*:*:*:*:*:*
cpe:2.3:o:engeniustech:esr900_firmware:1.1.0:*:*:*:*:*:*:*
cpe:2.3:o:engeniustech:esr900_firmware:1.2.2.23:*:*:*:*:*:*:*
cpe:2.3:o:engeniustech:esr900_firmware:1.3.0:*:*:*:*:*:*:*
cpe:2.3:o:engeniustech:esr900_firmware:1.3.1.26:*:*:*:*:*:*:*
cpe:2.3:o:engeniustech:esr900_firmware:1.3.5.18:*:*:*:*:*:*:*
cpe:2.3:o:engeniustech:esr900_firmware:1.4.0:*:*:*:*:*:*:*
cpe:2.3:o:engeniustech:esr900_firmware:1.4.3:*:*:*:*:*:*:*
cpe:2.3:o:engeniustech:esr900_firmware:1.4.5:*:*:*:*:*:*:*
Vendors & Products Engeniustech
Engeniustech epg5000
Engeniustech epg5000 Firmware
Engeniustech esr1200
Engeniustech esr1200 Firmware
Engeniustech esr1750
Engeniustech esr1750 Firmware
Engeniustech esr300
Engeniustech esr300 Firmware
Engeniustech esr350
Engeniustech esr350 Firmware
Engeniustech esr600
Engeniustech esr600 Firmware
Engeniustech esr900
Engeniustech esr900 Firmware
Metrics cvssV3_1

{'score': 9.8, 'vector': 'CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H'}

Type Values Removed Values Added
Metrics ssvc

{'options': {'Automatable': 'yes', 'Exploitation': 'poc', 'Technical Impact': 'total'}, 'version': '2.0.3'}

Type Values Removed Values Added
Description An OS command injection vulnerability exists in EnGenius EnShare Cloud Service version 1.4.11 and earlier. The usbinteract.cgi script fails to properly sanitize user input passed to the path parameter, allowing unauthenticated remote attackers to inject arbitrary shell commands. The injected commands are executed with root privileges, leading to full system compromise.
Title EnGenius EnShare IoT Gigabit Cloud Service Command Injection
Weaknesses CWE-20
CWE-78
References
Metrics cvssV4_0

{'score': 10, 'vector': 'CVSS:4.0/AV:N/AC:L/AT:N/PR:N/UI:N/VC:H/VI:H/VA:H/SC:H/SI:H/SA:H'}