EnGenius EnShare IoT Gigabit Cloud Service Command Injection
Default status is the baseline for the product, each version can override it (e.g. patched versions marked unaffected).
| Vendor | Product | Default status | Versions | ||||||
|---|---|---|---|---|---|---|---|---|---|
| EnGenius | EnShare IoT Gigabit Cloud Service | unaffected |
|
Configuration 1 [-]
| AND |
|
Configuration 2 [-]
| AND |
|
Configuration 3 [-]
| AND |
|
Configuration 4 [-]
| AND |
|
Configuration 5 [-]
| AND |
|
Configuration 6 [-]
| AND |
|
Configuration 7 [-]
| AND |
|
No data.
No data available yet.
No CVSS v3.0
No CVSS v2
This CVE is not in the KEV list.
Exploit prediction score: 24.8% (24.839% probability within 30 days)
| Type | Values Removed | Values Added |
|---|---|---|
| Description | An OS command injection vulnerability exists in EnGenius EnShare Cloud Service version 1.4.11 and earlier. The usbinteract.cgi script fails to properly sanitize user input passed to the path parameter, allowing unauthenticated remote attackers to inject arbitrary shell commands. The injected commands are executed with root privileges, leading to full system compromise. Exploitation evidence was observed by the Shadowserver Foundation on 2025-08-27 UTC. | An OS command injection vulnerability exists in EnGenius EnShare Cloud Service version 1.4.11 and earlier. The usbinteract.cgi script fails to properly sanitize user input passed to the path parameter, allowing unauthenticated remote attackers to inject arbitrary shell commands. The injected commands are executed with root privileges, leading to full system compromise. Exploitation evidence was observed by the Shadowserver Foundation on 2024-12-05 UTC. |
| Type | Values Removed | Values Added |
|---|---|---|
| Weaknesses | CWE-20 |
| Type | Values Removed | Values Added |
|---|---|---|
| Description | An OS command injection vulnerability exists in EnGenius EnShare Cloud Service version 1.4.11 and earlier. The usbinteract.cgi script fails to properly sanitize user input passed to the path parameter, allowing unauthenticated remote attackers to inject arbitrary shell commands. The injected commands are executed with root privileges, leading to full system compromise. | An OS command injection vulnerability exists in EnGenius EnShare Cloud Service version 1.4.11 and earlier. The usbinteract.cgi script fails to properly sanitize user input passed to the path parameter, allowing unauthenticated remote attackers to inject arbitrary shell commands. The injected commands are executed with root privileges, leading to full system compromise. Exploitation evidence was observed by the Shadowserver Foundation on 2025-08-27 UTC. |
| Type | Values Removed | Values Added |
|---|---|---|
| First Time appeared |
Engeniustech
Engeniustech epg5000 Engeniustech epg5000 Firmware Engeniustech esr1200 Engeniustech esr1200 Firmware Engeniustech esr1750 Engeniustech esr1750 Firmware Engeniustech esr300 Engeniustech esr300 Firmware Engeniustech esr350 Engeniustech esr350 Firmware Engeniustech esr600 Engeniustech esr600 Firmware Engeniustech esr900 Engeniustech esr900 Firmware |
|
| CPEs | cpe:2.3:h:engeniustech:epg5000:-:*:*:*:*:*:*:* cpe:2.3:h:engeniustech:esr1200:-:*:*:*:*:*:*:* cpe:2.3:h:engeniustech:esr1750:-:*:*:*:*:*:*:* cpe:2.3:h:engeniustech:esr300:-:*:*:*:*:*:*:* cpe:2.3:h:engeniustech:esr350:-:*:*:*:*:*:*:* cpe:2.3:h:engeniustech:esr600:-:*:*:*:*:*:*:* cpe:2.3:h:engeniustech:esr900:-:*:*:*:*:*:*:* cpe:2.3:o:engeniustech:epg5000_firmware:1.2.0:*:*:*:*:*:*:* cpe:2.3:o:engeniustech:epg5000_firmware:1.3.0:*:*:*:*:*:*:* cpe:2.3:o:engeniustech:epg5000_firmware:1.3.2:*:*:*:*:*:*:* cpe:2.3:o:engeniustech:epg5000_firmware:1.3.3.17:*:*:*:*:*:*:* cpe:2.3:o:engeniustech:epg5000_firmware:1.3.3:*:*:*:*:*:*:* cpe:2.3:o:engeniustech:epg5000_firmware:1.3.7.20:*:*:*:*:*:*:* cpe:2.3:o:engeniustech:epg5000_firmware:1.3.9.21:*:*:*:*:*:*:* cpe:2.3:o:engeniustech:esr1200_firmware:1.1.0:*:*:*:*:*:*:* cpe:2.3:o:engeniustech:esr1200_firmware:1.3.1.34:*:*:*:*:*:*:* cpe:2.3:o:engeniustech:esr1200_firmware:1.4.1:*:*:*:*:*:*:* cpe:2.3:o:engeniustech:esr1200_firmware:1.4.3:*:*:*:*:*:*:* cpe:2.3:o:engeniustech:esr1200_firmware:1.4.5:*:*:*:*:*:*:* cpe:2.3:o:engeniustech:esr1750_firmware:1.1.0:*:*:*:*:*:*:* cpe:2.3:o:engeniustech:esr1750_firmware:1.2.2.27:*:*:*:*:*:*:* cpe:2.3:o:engeniustech:esr1750_firmware:1.3.0:*:*:*:*:*:*:* cpe:2.3:o:engeniustech:esr1750_firmware:1.3.1.34:*:*:*:*:*:*:* cpe:2.3:o:engeniustech:esr1750_firmware:1.4.0:*:*:*:*:*:*:* cpe:2.3:o:engeniustech:esr1750_firmware:1.4.1:*:*:*:*:*:*:* cpe:2.3:o:engeniustech:esr1750_firmware:1.4.3:*:*:*:*:*:*:* cpe:2.3:o:engeniustech:esr1750_firmware:1.4.5:*:*:*:*:*:*:* cpe:2.3:o:engeniustech:esr300_firmware:1.1.0.28:*:*:*:*:*:*:* cpe:2.3:o:engeniustech:esr300_firmware:1.3.1.42:*:*:*:*:*:*:* cpe:2.3:o:engeniustech:esr300_firmware:1.4.0:*:*:*:*:*:*:* cpe:2.3:o:engeniustech:esr300_firmware:1.4.1.28:*:*:*:*:*:*:* cpe:2.3:o:engeniustech:esr300_firmware:1.4.2:*:*:*:*:*:*:* cpe:2.3:o:engeniustech:esr300_firmware:1.4.7:*:*:*:*:*:*:* cpe:2.3:o:engeniustech:esr300_firmware:1.4.9:*:*:*:*:*:*:* cpe:2.3:o:engeniustech:esr350_firmware:1.1.0.29:*:*:*:*:*:*:* cpe:2.3:o:engeniustech:esr350_firmware:1.3.1.41:*:*:*:*:*:*:* cpe:2.3:o:engeniustech:esr350_firmware:1.4.0:*:*:*:*:*:*:* cpe:2.3:o:engeniustech:esr350_firmware:1.4.11:*:*:*:*:*:*:* cpe:2.3:o:engeniustech:esr350_firmware:1.4.2:*:*:*:*:*:*:* cpe:2.3:o:engeniustech:esr350_firmware:1.4.5:*:*:*:*:*:*:* cpe:2.3:o:engeniustech:esr350_firmware:1.4.9:*:*:*:*:*:*:* cpe:2.3:o:engeniustech:esr600_firmware:1.1.0.50:*:*:*:*:*:*:* cpe:2.3:o:engeniustech:esr600_firmware:1.2.1.46:*:*:*:*:*:*:* cpe:2.3:o:engeniustech:esr600_firmware:1.3.1.63:*:*:*:*:*:*:* cpe:2.3:o:engeniustech:esr600_firmware:1.4.0.23:*:*:*:*:*:*:* cpe:2.3:o:engeniustech:esr600_firmware:1.4.11:*:*:*:*:*:*:* cpe:2.3:o:engeniustech:esr600_firmware:1.4.1:*:*:*:*:*:*:* cpe:2.3:o:engeniustech:esr600_firmware:1.4.2:*:*:*:*:*:*:* cpe:2.3:o:engeniustech:esr600_firmware:1.4.3:*:*:*:*:*:*:* cpe:2.3:o:engeniustech:esr600_firmware:1.4.5:*:*:*:*:*:*:* cpe:2.3:o:engeniustech:esr600_firmware:1.4.9:*:*:*:*:*:*:* cpe:2.3:o:engeniustech:esr900_firmware:1.1.0:*:*:*:*:*:*:* cpe:2.3:o:engeniustech:esr900_firmware:1.2.2.23:*:*:*:*:*:*:* cpe:2.3:o:engeniustech:esr900_firmware:1.3.0:*:*:*:*:*:*:* cpe:2.3:o:engeniustech:esr900_firmware:1.3.1.26:*:*:*:*:*:*:* cpe:2.3:o:engeniustech:esr900_firmware:1.3.5.18:*:*:*:*:*:*:* cpe:2.3:o:engeniustech:esr900_firmware:1.4.0:*:*:*:*:*:*:* cpe:2.3:o:engeniustech:esr900_firmware:1.4.3:*:*:*:*:*:*:* cpe:2.3:o:engeniustech:esr900_firmware:1.4.5:*:*:*:*:*:*:* |
|
| Vendors & Products |
Engeniustech
Engeniustech epg5000 Engeniustech epg5000 Firmware Engeniustech esr1200 Engeniustech esr1200 Firmware Engeniustech esr1750 Engeniustech esr1750 Firmware Engeniustech esr300 Engeniustech esr300 Firmware Engeniustech esr350 Engeniustech esr350 Firmware Engeniustech esr600 Engeniustech esr600 Firmware Engeniustech esr900 Engeniustech esr900 Firmware |
|
| Metrics |
cvssV3_1
|
| Type | Values Removed | Values Added |
|---|---|---|
| Metrics |
ssvc
|
| Type | Values Removed | Values Added |
|---|---|---|
| References |
|
| Type | Values Removed | Values Added |
|---|---|---|
| References |
|
| Type | Values Removed | Values Added |
|---|---|---|
| Description | An OS command injection vulnerability exists in EnGenius EnShare Cloud Service version 1.4.11 and earlier. The usbinteract.cgi script fails to properly sanitize user input passed to the path parameter, allowing unauthenticated remote attackers to inject arbitrary shell commands. The injected commands are executed with root privileges, leading to full system compromise. | |