{"affected": [{"affectedData": [{"defaultStatus": "unaffected", "modules": ["Web Management Interface (mp.asp command handler)"], "product": "Edimax EW-7438RPn Mini", "vendor": "Edimax", "versions": [{"lessThanOrEqual": "1.13", "status": "affected", "version": "0", "versionType": "custom"}]}], "source": "disclosure@vulncheck.com"}], "configurations": [{"nodes": [{"cpeMatch": [{"criteria": "cpe:2.3:o:edimax:ew-7438rpn_mini_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "82AD0A5F-41F6-480D-AF55-88F0F768B669", "versionEndIncluding": "1.13", "vulnerable": true}], "negate": false, "operator": "OR"}, {"cpeMatch": [{"criteria": "cpe:2.3:h:edimax:ew-7438rpn_mini:-:*:*:*:*:*:*:*", "matchCriteriaId": "883D1C81-1FD3-45CE-B1D8-85E760F4FF14", "vulnerable": false}], "negate": false, "operator": "OR"}], "operator": "AND"}], "cveTags": [], "descriptions": [{"lang": "en", "value": "An OS command injection vulnerability exists in the Edimax EW-7438RPn firmware version 1.13 and prior via the mp.asp form handler. The /goform/mp endpoint improperly handles user-supplied input to the command parameter. An authenticated attacker can inject shell commands using shell metacharacters to achieve arbitrary command execution as the root user. Exploitation evidence was observed by the Shadowserver Foundation on 2024-09-14 UTC."}, {"lang": "es", "value": "Existe una vulnerabilidad de inyecci\u00f3n de comandos del sistema operativo en el firmware 1.13 y anteriores del Edimax EW-7438RPn a trav\u00e9s del controlador de formularios mp.asp. El endpoint /goform/mp gestiona incorrectamente la entrada del usuario al par\u00e1metro de comando. Un atacante autenticado puede inyectar comandos de shell utilizando metacaracteres de shell para ejecutar comandos arbitrarios como usuario root."}], "id": "CVE-2025-34024", "lastModified": "2026-06-17T09:13:19.603", "metrics": {"cvssMetricV31": [{"cvssData": {"attackComplexity": "LOW", "attackVector": "NETWORK", "availabilityImpact": "HIGH", "baseScore": 8.8, "baseSeverity": "HIGH", "confidentialityImpact": "HIGH", "integrityImpact": "HIGH", "privilegesRequired": "LOW", "scope": "UNCHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H", "version": "3.1"}, "exploitabilityScore": 2.8, "impactScore": 5.9, "source": "nvd@nist.gov", "type": "Primary"}], "cvssMetricV40": [{"cvssData": {"Automatable": "NOT_DEFINED", "Recovery": "NOT_DEFINED", "Safety": "NOT_DEFINED", "attackComplexity": "LOW", "attackRequirements": "NONE", "attackVector": "NETWORK", "availabilityRequirement": "NOT_DEFINED", "baseScore": 9.4, "baseSeverity": "CRITICAL", "confidentialityRequirement": "NOT_DEFINED", "exploitMaturity": "NOT_DEFINED", "integrityRequirement": "NOT_DEFINED", "modifiedAttackComplexity": "NOT_DEFINED", "modifiedAttackRequirements": "NOT_DEFINED", "modifiedAttackVector": "NOT_DEFINED", "modifiedPrivilegesRequired": "NOT_DEFINED", "modifiedSubAvailabilityImpact": "NOT_DEFINED", "modifiedSubConfidentialityImpact": "NOT_DEFINED", "modifiedSubIntegrityImpact": "NOT_DEFINED", "modifiedUserInteraction": "NOT_DEFINED", "modifiedVulnAvailabilityImpact": "NOT_DEFINED", "modifiedVulnConfidentialityImpact": "NOT_DEFINED", "modifiedVulnIntegrityImpact": "NOT_DEFINED", "privilegesRequired": "LOW", "providerUrgency": "NOT_DEFINED", "subAvailabilityImpact": "HIGH", "subConfidentialityImpact": "HIGH", "subIntegrityImpact": "HIGH", "userInteraction": "NONE", "valueDensity": "NOT_DEFINED", "vectorString": "CVSS:4.0/AV:N/AC:L/AT:N/PR:L/UI:N/VC:H/VI:H/VA:H/SC:H/SI:H/SA:H/E:X/CR:X/IR:X/AR:X/MAV:X/MAC:X/MAT:X/MPR:X/MUI:X/MVC:X/MVI:X/MVA:X/MSC:X/MSI:X/MSA:X/S:X/AU:X/R:X/V:X/RE:X/U:X", "version": "4.0", "vulnAvailabilityImpact": "HIGH", "vulnConfidentialityImpact": "HIGH", "vulnIntegrityImpact": "HIGH", "vulnerabilityResponseEffort": "NOT_DEFINED"}, "source": "disclosure@vulncheck.com", "type": "Secondary"}], "ssvcV203": [{"source": "134c704f-9b21-4f2e-91b3-4a467353bcc0", "ssvcData": {"id": "CVE-2025-34024", "options": [{"exploitation": "none"}, {"automatable": "yes"}, {"technicalImpact": "total"}], "role": "CISA Coordinator", "timestamp": "2025-06-23T20:39:27.231637Z", "version": "2.0.3"}}]}, "published": "2025-06-20T19:15:37.053", "references": [{"source": "disclosure@vulncheck.com", "tags": ["Exploit", "Third Party Advisory"], "url": "https://vulncheck.com/advisories/edimax-ew-7438rpn-command-injections"}, {"source": "disclosure@vulncheck.com", "tags": ["Third Party Advisory"], "url": "https://www.broadcom.com/support/security-center/attacksignatures/detail?asid=32163"}, {"source": "disclosure@vulncheck.com", "tags": ["Product"], "url": "https://www.edimax.com/edimax/merchandise/merchandise_detail/data/edimax/global/wi-fi_range_extenders_n300/ew-7438rpn_mini/"}, {"source": "disclosure@vulncheck.com", "tags": ["Exploit", "VDB Entry"], "url": "https://www.exploit-db.com/exploits/48377"}], "sourceIdentifier": "disclosure@vulncheck.com", "vulnStatus": "Modified", "weaknesses": [{"description": [{"lang": "en", "value": "CWE-78"}], "source": "disclosure@vulncheck.com", "type": "Secondary"}]}