{"affected": [{"affectedData": [{"defaultStatus": "unknown", "product": "RUGGEDCOM ROX MX5000", "vendor": "Siemens", "versions": [{"lessThan": "V2.16.5", "status": "affected", "version": "0", "versionType": "custom"}]}, {"defaultStatus": "unknown", "product": "RUGGEDCOM ROX MX5000RE", "vendor": "Siemens", "versions": [{"lessThan": "V2.16.5", "status": "affected", "version": "0", "versionType": "custom"}]}, {"defaultStatus": "unknown", "product": "RUGGEDCOM ROX RX1400", "vendor": "Siemens", "versions": [{"lessThan": "V2.16.5", "status": "affected", "version": "0", "versionType": "custom"}]}, {"defaultStatus": "unknown", "product": "RUGGEDCOM ROX RX1500", "vendor": "Siemens", "versions": [{"lessThan": "V2.16.5", "status": "affected", "version": "0", "versionType": "custom"}]}, {"defaultStatus": "unknown", "product": "RUGGEDCOM ROX RX1501", "vendor": "Siemens", "versions": [{"lessThan": "V2.16.5", "status": "affected", "version": "0", "versionType": "custom"}]}, {"defaultStatus": "unknown", "product": "RUGGEDCOM ROX RX1510", "vendor": "Siemens", "versions": [{"lessThan": "V2.16.5", "status": "affected", "version": "0", "versionType": "custom"}]}, {"defaultStatus": "unknown", "product": "RUGGEDCOM ROX RX1511", "vendor": "Siemens", "versions": [{"lessThan": "V2.16.5", "status": "affected", "version": "0", "versionType": "custom"}]}, {"defaultStatus": "unknown", "product": "RUGGEDCOM ROX RX1512", "vendor": "Siemens", "versions": [{"lessThan": "V2.16.5", "status": "affected", "version": "0", "versionType": "custom"}]}, {"defaultStatus": "unknown", "product": "RUGGEDCOM ROX RX1524", "vendor": "Siemens", "versions": [{"lessThan": "V2.16.5", "status": "affected", "version": "0", "versionType": "custom"}]}, {"defaultStatus": "unknown", "product": "RUGGEDCOM ROX RX1536", "vendor": "Siemens", "versions": [{"lessThan": "V2.16.5", "status": "affected", "version": "0", "versionType": "custom"}]}, {"defaultStatus": "unknown", "product": "RUGGEDCOM ROX RX5000", "vendor": "Siemens", "versions": [{"lessThan": "V2.16.5", "status": "affected", "version": "0", "versionType": "custom"}]}], "source": "productcert@siemens.com"}], "cveTags": [], "descriptions": [{"lang": "en", "value": "A vulnerability has been identified in RUGGEDCOM ROX MX5000 (All versions < V2.16.5), RUGGEDCOM ROX MX5000RE (All versions < V2.16.5), RUGGEDCOM ROX RX1400 (All versions < V2.16.5), RUGGEDCOM ROX RX1500 (All versions < V2.16.5), RUGGEDCOM ROX RX1501 (All versions < V2.16.5), RUGGEDCOM ROX RX1510 (All versions < V2.16.5), RUGGEDCOM ROX RX1511 (All versions < V2.16.5), RUGGEDCOM ROX RX1512 (All versions < V2.16.5), RUGGEDCOM ROX RX1524 (All versions < V2.16.5), RUGGEDCOM ROX RX1536 (All versions < V2.16.5), RUGGEDCOM ROX RX5000 (All versions < V2.16.5). The 'ping' tool in the web interface of affected devices is vulnerable to command injection due to missing server side input sanitation. This could allow an authenticated remote attacker to execute arbitrary code with root privileges."}, {"lang": "es", "value": "Se ha identificado una vulnerabilidad en RUGGEDCOM ROX MX5000 (Todas las versiones < V2.16.5), RUGGEDCOM ROX MX5000RE (Todas las versiones < V2.16.5), RUGGEDCOM ROX RX1400 (Todas las versiones < V2.16.5), RUGGEDCOM ROX RX1500 (Todas las versiones < V2.16.5), RUGGEDCOM ROX RX1501 (Todas las versiones < V2.16.5), RUGGEDCOM ROX RX1510 (Todas las versiones < V2.16.5), RUGGEDCOM ROX RX1511 (Todas las versiones < V2.16.5), RUGGEDCOM ROX RX1512 (Todas las versiones < V2.16.5), RUGGEDCOM ROX RX1524 (Todas las versiones < V2.16.5), RUGGEDCOM ROX RX1536 (Todas las versiones < V2.16.5), RUGGEDCOM ROX RX1536 (Todas las versiones < V2.16.5), RUGGEDCOM ROX RX1540 (Todas las versiones < V2.16.5), RUGGEDCOM ROX RX1550 (Todas las versiones < V2.16.5), RUGGEDCOM ROX RX1560 (Todas las versiones < V2.16.5), RUGGEDCOM ROX RX1570 (Todas las versiones < V2.16.5), RUGGEDCOM ROX RX1580 (Todas las versiones < V2.16.5), RUGGEDCOM ROX RX1590 (Todas las versiones < V2.16.5), RUGGEDCOM ROX RX1600 (Todas las versiones < V2.16.5), RUGGEDCOM ROX RX1610 (Todas las versiones < V2.16.5), RUGGEDCOM ROX RX16 V2.16.5), RUGGEDCOM ROX RX5000 (Todas las versiones anteriores a V2.16.5). La herramienta \"ping\" en la interfaz web de los dispositivos afectados es vulnerable a la inyecci\u00f3n de comandos debido a la falta de depuraci\u00f3n de la entrada del servidor. Esto podr\u00eda permitir que un atacante remoto autenticado ejecute c\u00f3digo arbitrario con privilegios de root."}], "id": "CVE-2025-32469", "lastModified": "2026-06-17T09:12:02.833", "metrics": {"cvssMetricV31": [{"cvssData": {"attackComplexity": "LOW", "attackVector": "NETWORK", "availabilityImpact": "HIGH", "baseScore": 9.9, "baseSeverity": "CRITICAL", "confidentialityImpact": "HIGH", "integrityImpact": "HIGH", "privilegesRequired": "LOW", "scope": "CHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:C/C:H/I:H/A:H", "version": "3.1"}, "exploitabilityScore": 3.1, "impactScore": 6.0, "source": "productcert@siemens.com", "type": "Secondary"}], "cvssMetricV40": [{"cvssData": {"Automatable": "NOT_DEFINED", "Recovery": "NOT_DEFINED", "Safety": "NOT_DEFINED", "attackComplexity": "LOW", "attackRequirements": "NONE", "attackVector": "NETWORK", "availabilityRequirement": "NOT_DEFINED", "baseScore": 9.4, "baseSeverity": "CRITICAL", "confidentialityRequirement": "NOT_DEFINED", "exploitMaturity": "NOT_DEFINED", "integrityRequirement": "NOT_DEFINED", "modifiedAttackComplexity": "NOT_DEFINED", "modifiedAttackRequirements": "NOT_DEFINED", "modifiedAttackVector": "NOT_DEFINED", "modifiedPrivilegesRequired": "NOT_DEFINED", "modifiedSubAvailabilityImpact": "NOT_DEFINED", "modifiedSubConfidentialityImpact": "NOT_DEFINED", "modifiedSubIntegrityImpact": "NOT_DEFINED", "modifiedUserInteraction": "NOT_DEFINED", "modifiedVulnAvailabilityImpact": "NOT_DEFINED", "modifiedVulnConfidentialityImpact": "NOT_DEFINED", "modifiedVulnIntegrityImpact": "NOT_DEFINED", "privilegesRequired": "LOW", "providerUrgency": "NOT_DEFINED", "subAvailabilityImpact": "HIGH", "subConfidentialityImpact": "HIGH", "subIntegrityImpact": "HIGH", "userInteraction": "NONE", "valueDensity": "NOT_DEFINED", "vectorString": "CVSS:4.0/AV:N/AC:L/AT:N/PR:L/UI:N/VC:H/VI:H/VA:H/SC:H/SI:H/SA:H/E:X/CR:X/IR:X/AR:X/MAV:X/MAC:X/MAT:X/MPR:X/MUI:X/MVC:X/MVI:X/MVA:X/MSC:X/MSI:X/MSA:X/S:X/AU:X/R:X/V:X/RE:X/U:X", "version": "4.0", "vulnAvailabilityImpact": "HIGH", "vulnConfidentialityImpact": "HIGH", "vulnIntegrityImpact": "HIGH", "vulnerabilityResponseEffort": "NOT_DEFINED"}, "source": "productcert@siemens.com", "type": "Secondary"}], "ssvcV203": [{"source": "134c704f-9b21-4f2e-91b3-4a467353bcc0", "ssvcData": {"id": "CVE-2025-32469", "options": [{"exploitation": "none"}, {"automatable": "no"}, {"technicalImpact": "total"}], "role": "CISA Coordinator", "timestamp": "2025-05-13T14:01:55.562100Z", "version": "2.0.3"}}]}, "published": "2025-05-13T10:15:25.180", "references": [{"source": "productcert@siemens.com", "url": "https://cert-portal.siemens.com/productcert/html/ssa-301229.html"}], "sourceIdentifier": "productcert@siemens.com", "vulnStatus": "Deferred", "weaknesses": [{"description": [{"lang": "en", "value": "CWE-602"}], "source": "productcert@siemens.com", "type": "Secondary"}]}