Remote Code Execution in CGM CLININET
Default status is the baseline for the product, each version can override it (e.g. patched versions marked unaffected).
| Vendor | Product | Default status | Versions | ||||||
|---|---|---|---|---|---|---|---|---|---|
| CGM | CGM CLININET | unknown |
|
No data.
No data.
| Vendor | Product | Versions | ||||||||
|---|---|---|---|---|---|---|---|---|---|---|
| Cgm | Cgm Clininet |
|
No CVSS v3.1
No CVSS v3.0
No CVSS v2
This CVE is not in the KEV list.
Exploit prediction score: < 1% (0.263% probability within 30 days)
| Type | Values Removed | Values Added |
|---|---|---|
| Metrics |
ssvc
|
| Type | Values Removed | Values Added |
|---|---|---|
| Description | In the CGM CLININET application server, multiple processes responsible for HL7 communication with external systems run with root privileges while processing untrusted data received from those external systems. An attacker in adjacent network able to send data to these HL7 communication processes can achieve remote code execution with root privileges. The vulnerability was confirmed to affect versions up to 2026.MS3 but later versions may also be vulnerable. | |
| Title | Remote Code Execution in CGM CLININET | |
| First Time appeared |
Cgm
Cgm cgm Clininet |
|
| Weaknesses | CWE-250 | |
| CPEs | cpe:2.3:a:cgm:cgm_clininet:*:*:*:*:*:*:*:* | |
| Vendors & Products |
Cgm
Cgm cgm Clininet |
|
| References |
| |
| Metrics |
cvssV4_0
|