AutomationDirect CLICK Programmable Logic Controller Plaintext Storage of a Password
Default status is the baseline for the product, each version can override it (e.g. patched versions marked unaffected).
| Vendor | Product | Default status | Versions | |||||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| AutomationDirect | CLICK Programmable Logic Controller | unaffected |
|
No data.
No data.
| Vendor | Product | Versions |
|---|---|---|
| Automationdirect | Click Plc | — |
Vendor Solution
AutomationDirect recommends that users update CLICK PLUS and firmware to V3.90.
Vendor Workaround
If the update cannot be applied right away, the following compensating controls are recommended until the upgrade can be performed: * Network Isolation – Disconnect the CLICK PLUS PLC from external networks (e.g., the internet or corporate LAN) to reduce exposure. * Secure Communications – Use only trusted, dedicated internal networks or air-gapped systems for device communication. * Access Control – Restrict both physical and logical access to authorized personnel only. * Application Whitelisting – Configure whitelisting so that only trusted, pre-approved applications are allowed to run. Block any unauthorized software. * Endpoint Protection – Use antivirus or EDR tools and configure host-based firewalls to block unauthorized access attempts. * Logging & Monitoring – Enable and regularly review system logs to detect suspicious or unauthorized activity. * Backup & Recovery – Maintain secure, tested backups of the PLC and its configurations to minimize downtime in case of an incident. * Ongoing Risk Assessment – Continuously evaluate risks associated with running outdated firmware and adjust compensating measures accordingly.
No CVSS v4.0
No CVSS v3.0
No CVSS v2
This CVE is not in the KEV list.
Exploit prediction score: < 1% (0.117% probability within 30 days)
| Type | Values Removed | Values Added |
|---|---|---|
| Metrics |
ssvc
|
| Type | Values Removed | Values Added |
|---|---|---|
| First Time appeared |
Automationdirect
Automationdirect click Plc |
|
| Vendors & Products |
Automationdirect
Automationdirect click Plc |
| Type | Values Removed | Values Added |
|---|---|---|
| Description | An attacker could decrypt sensitive data, impersonate legitimate users or devices, and potentially gain access to network resources for lateral attacks. | |
| Title | AutomationDirect CLICK Programmable Logic Controller Plaintext Storage of a Password | |