Edimax BR-6208AC Web-based Configuration formALGSetup redirect
Default status is the baseline for the product, each version can override it (e.g. patched versions marked unaffected).
| Vendor | Product | Default status | Versions | |||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|
| Edimax | BR-6208AC | affected |
|
Configuration 1 [-]
| AND |
|
No data.
| Vendor | Product | Versions |
|---|---|---|
| Edimax | Br-6208ac V1 | — |
This CVE is not in the KEV list.
Exploit prediction score: < 1% (0.264% probability within 30 days)
| Type | Values Removed | Values Added |
|---|---|---|
| Description | A weakness has been identified in Edimax BR-6208AC 1.02/1.03. Affected by this issue is the function formALGSetup of the file /goform/formALGSetup of the component Web-based Configuration Interface. This manipulation of the argument wlan-url causes open redirect. The attack is possible to be carried out remotely. The exploit has been made available to the public and could be exploited. Edimax confirms this issue: "The product mentioned, EDIMAX BR-6208AC V2, has reached its End of Life (EOL) status. It is no longer supported or maintained by Edimax, and it is no longer available for purchase in the market. Consequently, there will be no further firmware updates or patches for this device. We recommend users upgrade to newer models for better security." This vulnerability only affects products that are no longer supported by the maintainer. | A weakness has been identified in Edimax BR-6208AC 1.02/1.03. Affected by this issue is the function formALGSetup of the file /goform/formALGSetup of the component Web-based Configuration Interface. This manipulation of the argument wlan-url causes open redirect. The attack is possible to be carried out remotely. The exploit has been made available to the public and could be used for attacks. Edimax confirms this issue: "The product mentioned, EDIMAX BR-6208AC V2, has reached its End of Life (EOL) status. It is no longer supported or maintained by Edimax, and it is no longer available for purchase in the market. Consequently, there will be no further firmware updates or patches for this device. We recommend users upgrade to newer models for better security." This vulnerability only affects products that are no longer supported by the maintainer. |
| CPEs | cpe:2.3:o:edimax:br-6208ac_firmware:*:*:*:*:*:*:*:* |
| Type | Values Removed | Values Added |
|---|---|---|
| First Time appeared |
Edimax br-6208ac Firmware
Edimax br-6208ac V2 |
|
| CPEs | cpe:2.3:h:edimax:br-6208ac_v2:-:*:*:*:*:*:*:* cpe:2.3:o:edimax:br-6208ac_firmware:1.02:*:*:*:*:*:*:* cpe:2.3:o:edimax:br-6208ac_firmware:1.03:*:*:*:*:*:*:* |
|
| Vendors & Products |
Edimax br-6208ac Firmware
Edimax br-6208ac V2 |
| Type | Values Removed | Values Added |
|---|---|---|
| First Time appeared |
Edimax
Edimax br-6208ac V1 |
|
| Vendors & Products |
Edimax
Edimax br-6208ac V1 |
| Type | Values Removed | Values Added |
|---|---|---|
| Metrics |
ssvc
|
| Type | Values Removed | Values Added |
|---|---|---|
| Description | A weakness has been identified in Edimax BR-6208AC 1.02/1.03. Affected by this issue is the function formALGSetup of the file /goform/formALGSetup of the component Web-based Configuration Interface. This manipulation of the argument wlan-url causes open redirect. The attack is possible to be carried out remotely. The exploit has been made available to the public and could be exploited. Edimax confirms this issue: "The product mentioned, EDIMAX BR-6208AC V2, has reached its End of Life (EOL) status. It is no longer supported or maintained by Edimax, and it is no longer available for purchase in the market. Consequently, there will be no further firmware updates or patches for this device. We recommend users upgrade to newer models for better security." This vulnerability only affects products that are no longer supported by the maintainer. | |
| Title | Edimax BR-6208AC Web-based Configuration formALGSetup redirect | |
| Weaknesses | CWE-601 | |
| References |
| |
| Metrics |
cvssV2_0
|