CVE-2025-15258

Edimax BR-6208AC Web-based Configuration formALGSetup redirect

Published Dec 30, 2025 CVSS 4.0 · 5.1 Medium EPSS < 1% KEV · Not listed
Description
A weakness has been identified in Edimax BR-6208AC 1.02/1.03. Affected by this issue is the function formALGSetup of the file /goform/formALGSetup of the component Web-based Configuration Interface. This manipulation of the argument wlan-url causes open redirect. The attack is possible to be carried out remotely. The exploit has been made available to the public and could be used for attacks. Edimax confirms this issue: "The product mentioned, EDIMAX BR-6208AC V2, has reached its End of Life (EOL) status. It is no longer supported or maintained by Edimax, and it is no longer available for purchase in the market. Consequently, there will be no further firmware updates or patches for this device. We recommend users upgrade to newer models for better security." This vulnerability only affects products that are no longer supported by the maintainer.

Remediation

No solution or workaround provided in the CVE record

Tracking

Sign in to view the affected projects.

Advisories

No advisories available
History
Type Values Removed Values Added
Description A weakness has been identified in Edimax BR-6208AC 1.02/1.03. Affected by this issue is the function formALGSetup of the file /goform/formALGSetup of the component Web-based Configuration Interface. This manipulation of the argument wlan-url causes open redirect. The attack is possible to be carried out remotely. The exploit has been made available to the public and could be exploited. Edimax confirms this issue: "The product mentioned, EDIMAX BR-6208AC V2, has reached its End of Life (EOL) status. It is no longer supported or maintained by Edimax, and it is no longer available for purchase in the market. Consequently, there will be no further firmware updates or patches for this device. We recommend users upgrade to newer models for better security." This vulnerability only affects products that are no longer supported by the maintainer. A weakness has been identified in Edimax BR-6208AC 1.02/1.03. Affected by this issue is the function formALGSetup of the file /goform/formALGSetup of the component Web-based Configuration Interface. This manipulation of the argument wlan-url causes open redirect. The attack is possible to be carried out remotely. The exploit has been made available to the public and could be used for attacks. Edimax confirms this issue: "The product mentioned, EDIMAX BR-6208AC V2, has reached its End of Life (EOL) status. It is no longer supported or maintained by Edimax, and it is no longer available for purchase in the market. Consequently, there will be no further firmware updates or patches for this device. We recommend users upgrade to newer models for better security." This vulnerability only affects products that are no longer supported by the maintainer.
CPEs cpe:2.3:o:edimax:br-6208ac_firmware:*:*:*:*:*:*:*:*
Type Values Removed Values Added
First Time appeared Edimax br-6208ac Firmware
Edimax br-6208ac V2
CPEs cpe:2.3:h:edimax:br-6208ac_v2:-:*:*:*:*:*:*:*
cpe:2.3:o:edimax:br-6208ac_firmware:1.02:*:*:*:*:*:*:*
cpe:2.3:o:edimax:br-6208ac_firmware:1.03:*:*:*:*:*:*:*
Vendors & Products Edimax br-6208ac Firmware
Edimax br-6208ac V2
Type Values Removed Values Added
First Time appeared Edimax
Edimax br-6208ac V1
Vendors & Products Edimax
Edimax br-6208ac V1
Type Values Removed Values Added
Metrics ssvc

{'options': {'Automatable': 'no', 'Exploitation': 'poc', 'Technical Impact': 'partial'}, 'version': '2.0.3'}

Type Values Removed Values Added
Description A weakness has been identified in Edimax BR-6208AC 1.02/1.03. Affected by this issue is the function formALGSetup of the file /goform/formALGSetup of the component Web-based Configuration Interface. This manipulation of the argument wlan-url causes open redirect. The attack is possible to be carried out remotely. The exploit has been made available to the public and could be exploited. Edimax confirms this issue: "The product mentioned, EDIMAX BR-6208AC V2, has reached its End of Life (EOL) status. It is no longer supported or maintained by Edimax, and it is no longer available for purchase in the market. Consequently, there will be no further firmware updates or patches for this device. We recommend users upgrade to newer models for better security." This vulnerability only affects products that are no longer supported by the maintainer.
Title Edimax BR-6208AC Web-based Configuration formALGSetup redirect
Weaknesses CWE-601
References
Metrics cvssV2_0

{'score': 4, 'vector': 'AV:N/AC:L/Au:S/C:N/I:P/A:N/E:POC/RL:ND/RC:C'}

cvssV3_0

{'score': 3.5, 'vector': 'CVSS:3.0/AV:N/AC:L/PR:L/UI:R/S:U/C:N/I:L/A:N/E:P/RL:X/RC:C'}

cvssV3_1

{'score': 3.5, 'vector': 'CVSS:3.1/AV:N/AC:L/PR:L/UI:R/S:U/C:N/I:L/A:N/E:P/RL:X/RC:C'}

cvssV4_0

{'score': 5.1, 'vector': 'CVSS:4.0/AV:N/AC:L/AT:N/PR:L/UI:P/VC:N/VI:L/VA:N/SC:N/SI:N/SA:N/E:P'}

Weaknesses

Sources

Status
PUBLISHED
Assigner
VulDB
Published
Updated
Feb 24, 2026, 6:18 AM
Reserved
Dec 29, 2025, 9:34 AM
Status
Modified
Published
Dec 30, 2025, 6:15 PM
Modified