Credential Disclosure vulnerability in Radiometer Products
Default status is the baseline for the product, each version can override it (e.g. patched versions marked unaffected).
| Vendor | Product | Default status | Versions | |||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|
| Radiometer Medical Aps | ABL90 FLEX and ABL90 FLEX PLUS Analyzers | unaffected |
|
|||||||||
| Radiometer Medical Aps | AQT90 FLEX Analyzers | unaffected |
|
|||||||||
| Radiometer Medical Aps | ABL800 BASIC and ABL800 FLEX analyzers | unaffected |
|
No data.
No data.
| Vendor | Product | Versions |
|---|---|---|
| Radiometer | Abl800 Basic Analyzer | — |
| Radiometer | Abl800 Flex Analyzer | — |
| Radiometer | Abl90 Flex Analyzer | — |
| Radiometer | Abl90 Flex Plus Analyzer | — |
| Radiometer | Aqt90 Flex Analyzer | — |
Vendor Solution
Local Radiometer representatives will contact all affected customers to discuss a permanent solution.
Vendor Workaround
Only authorized people can physically access the analyzer.
No CVSS v4.0
No CVSS v3.0
No CVSS v2
This CVE is not in the KEV list.
Exploit prediction score: < 1% (0.135% probability within 30 days)
| Link | Providers |
|---|---|
| https://www.radiometer.com/myradiometer |
|
| Type | Values Removed | Values Added |
|---|---|---|
| Metrics |
ssvc
|
| Type | Values Removed | Values Added |
|---|---|---|
| First Time appeared |
Radiometer
Radiometer abl800 Basic Analyzer Radiometer abl800 Flex Analyzer Radiometer abl90 Flex Analyzer Radiometer abl90 Flex Plus Analyzer Radiometer aqt90 Flex Analyzer |
|
| Vendors & Products |
Radiometer
Radiometer abl800 Basic Analyzer Radiometer abl800 Flex Analyzer Radiometer abl90 Flex Analyzer Radiometer abl90 Flex Plus Analyzer Radiometer aqt90 Flex Analyzer |
| Type | Values Removed | Values Added |
|---|---|---|
| Description | A vulnerability exists in multiple Radiometer products that allow an attacker with physical access to the analyzer possibility to extract credential information. The vulnerability is due to a weakness in the design and insufficient credential protection in operating system. Other related CVE's are CVE-2025-14095 and CVE-2025-14097. Affected customers have been informed about this vulnerability. This CVE is being published to provide transparency. Required Configuration for Exposure: Attacker requires physical access to the analyzer. Temporary work Around: Only authorized people can physically access the analyzer. Permanent solution: Local Radiometer representatives will contact all affected customers to discuss a permanent solution. Exploit Status: Researchers have provided a working proof-of-concept (PoC). Radiometer is not aware of any public exploit code at the time of this publication. | A vulnerability exists in multiple Radiometer products that allow an attacker with physical access to the analyzer possibility to extract credential information. The vulnerability is due to a weakness in the design and insufficient credential protection in operating system. Other related CVE's are CVE-2025-14095 & CVE-2025-14097. Affected customers have been informed about this vulnerability. This CVE is being published to provide transparency. Required Configuration for Exposure: Attacker requires physical access to the analyzer. Temporary work Around: Only authorized people can physically access the analyzer. Permanent solution: Local Radiometer representatives will contact all affected customers to discuss a permanent solution. Exploit Status: Researchers have provided a working proof-of-concept (PoC). Radiometer is not aware of any public exploit code at the time of this publication. |
| Type | Values Removed | Values Added |
|---|---|---|
| Description | A vulnerability exists in multiple Radiometer products that allow an attacker with physical access to the analyzer possibility to extract credential information. The vulnerability is due to a weakness in the design and insufficient credential protection in operating system. Other related CVE's are CVE-2025-14095 and CVE-2025-14097. Affected customers have been informed about this vulnerability. This CVE is being published to provide transparency. Required Configuration for Exposure: Attacker requires physical access to the analyzer. Temporary work Around: Only authorized people can physically access the analyzer. Permanent solution: Local Radiometer representatives will contact all affected customers to discuss a permanent solution. Exploit Status: Researchers have provided a working proof-of-concept (PoC). Radiometer is not aware of any public exploit code at the time of this publication. | |
| Title | Credential Disclosure vulnerability in Radiometer Products | |
| Weaknesses | CWE-250 CWE-798 |
|