{"affected": [{"affectedData": [{"defaultStatus": "unaffected", "product": "Modicon M241/M251", "vendor": "Schneider Electric", "versions": [{"status": "affected", "version": "Versions prior to 5.4.13.12"}]}, {"defaultStatus": "unaffected", "product": "Modicon M262", "vendor": "Schneider Electric", "versions": [{"status": "affected", "version": "Versions prior to 5.4.10.12"}]}], "source": "cybersecurity@se.com"}], "configurations": [{"nodes": [{"cpeMatch": [{"criteria": "cpe:2.3:o:schneider-electric:modicon_m241_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "31DCF35D-C99C-4FB5-926C-09782051FC9A", "versionEndExcluding": "5.4.13.12", "vulnerable": true}], "negate": false, "operator": "OR"}, {"cpeMatch": [{"criteria": "cpe:2.3:h:schneider-electric:modicon_m241:-:*:*:*:*:*:*:*", "matchCriteriaId": "4D8FD9D9-F59F-470E-9F7F-CDDD80B0633C", "vulnerable": false}], "negate": false, "operator": "OR"}], "operator": "AND"}, {"nodes": [{"cpeMatch": [{"criteria": "cpe:2.3:o:schneider-electric:modicon_m251_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "4D5BD37D-AD63-4A0B-B959-1F731D39E51C", "versionEndExcluding": "5.4.13.12", "vulnerable": true}], "negate": false, "operator": "OR"}, {"cpeMatch": [{"criteria": "cpe:2.3:h:schneider-electric:modicon_m251:-:*:*:*:*:*:*:*", "matchCriteriaId": "B8E03A25-B0B6-4BA2-80BC-52C16A6837E0", "vulnerable": false}], "negate": false, "operator": "OR"}], "operator": "AND"}, {"nodes": [{"cpeMatch": [{"criteria": "cpe:2.3:o:schneider-electric:modicon_m262_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "1DF3A045-3B0A-440F-A94D-28FA4EBD82F1", "versionEndExcluding": "5.4.10.12", "vulnerable": true}], "negate": false, "operator": "OR"}, {"cpeMatch": [{"criteria": "cpe:2.3:h:schneider-electric:modicon_m262:-:*:*:*:*:*:*:*", "matchCriteriaId": "F2C151DF-D716-4F2F-8129-9D1B88430A72", "vulnerable": false}], "negate": false, "operator": "OR"}], "operator": "AND"}], "cveTags": [], "descriptions": [{"lang": "en", "value": "CWE-404 Improper Resource Shutdown or Release vulnerability exists that could cause partial Denial of Service on Machine Expert protocol when an unauthenticated attacker sends malicious payload to occupy active communication channels."}, {"lang": "es", "value": "Existe una vulnerabilidad CWE-404 de cierre o liberaci\u00f3n inadecuados de recursos que podr\u00eda causar una denegaci\u00f3n de servicio parcial en el protocolo Machine Expert cuando un atacante no autenticado env\u00eda una carga \u00fatil maliciosa para ocupar canales de comunicaci\u00f3n activos."}], "id": "CVE-2025-13901", "lastModified": "2026-06-23T14:38:33.210", "metrics": {"cvssMetricV31": [{"cvssData": {"attackComplexity": "LOW", "attackVector": "NETWORK", "availabilityImpact": "LOW", "baseScore": 5.3, "baseSeverity": "MEDIUM", "confidentialityImpact": "NONE", "integrityImpact": "NONE", "privilegesRequired": "NONE", "scope": "UNCHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:L", "version": "3.1"}, "exploitabilityScore": 3.9, "impactScore": 1.4, "source": "nvd@nist.gov", "type": "Primary"}], "cvssMetricV40": [{"cvssData": {"Automatable": "NOT_DEFINED", "Recovery": "NOT_DEFINED", "Safety": "NOT_DEFINED", "attackComplexity": "LOW", "attackRequirements": "NONE", "attackVector": "NETWORK", "availabilityRequirement": "NOT_DEFINED", "baseScore": 6.9, "baseSeverity": "MEDIUM", "confidentialityRequirement": "NOT_DEFINED", "exploitMaturity": "NOT_DEFINED", "integrityRequirement": "NOT_DEFINED", "modifiedAttackComplexity": "NOT_DEFINED", "modifiedAttackRequirements": "NOT_DEFINED", "modifiedAttackVector": "NOT_DEFINED", "modifiedPrivilegesRequired": "NOT_DEFINED", "modifiedSubAvailabilityImpact": "NOT_DEFINED", "modifiedSubConfidentialityImpact": "NOT_DEFINED", "modifiedSubIntegrityImpact": "NOT_DEFINED", "modifiedUserInteraction": "NOT_DEFINED", "modifiedVulnAvailabilityImpact": "NOT_DEFINED", "modifiedVulnConfidentialityImpact": "NOT_DEFINED", "modifiedVulnIntegrityImpact": "NOT_DEFINED", "privilegesRequired": "NONE", "providerUrgency": "NOT_DEFINED", "subAvailabilityImpact": "NONE", "subConfidentialityImpact": "NONE", "subIntegrityImpact": "NONE", "userInteraction": "NONE", "valueDensity": "NOT_DEFINED", "vectorString": "CVSS:4.0/AV:N/AC:L/AT:N/PR:N/UI:N/VC:N/VI:N/VA:L/SC:N/SI:N/SA:N/E:X/CR:X/IR:X/AR:X/MAV:X/MAC:X/MAT:X/MPR:X/MUI:X/MVC:X/MVI:X/MVA:X/MSC:X/MSI:X/MSA:X/S:X/AU:X/R:X/V:X/RE:X/U:X", "version": "4.0", "vulnAvailabilityImpact": "LOW", "vulnConfidentialityImpact": "NONE", "vulnIntegrityImpact": "NONE", "vulnerabilityResponseEffort": "NOT_DEFINED"}, "source": "cybersecurity@se.com", "type": "Secondary"}], "ssvcV203": [{"source": "134c704f-9b21-4f2e-91b3-4a467353bcc0", "ssvcData": {"id": "CVE-2025-13901", "options": [{"exploitation": "none"}, {"automatable": "yes"}, {"technicalImpact": "partial"}], "role": "CISA Coordinator", "timestamp": "2026-03-10T17:24:36.387715Z", "version": "2.0.3"}}]}, "published": "2026-03-10T18:17:52.063", "references": [{"source": "cybersecurity@se.com", "tags": ["Vendor Advisory", "Mitigation", "Patch"], "url": "https://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2026-069-01&p_enDocType=Security+and+Safety+Notice&p_File_Name=SEVD-2026-069-01.pdf"}], "sourceIdentifier": "cybersecurity@se.com", "vulnStatus": "Analyzed", "weaknesses": [{"description": [{"lang": "en", "value": "CWE-404"}], "source": "cybersecurity@se.com", "type": "Secondary"}]}