CVE-2025-11527

Tenda AC7 fast_setting_pppoe_set stack-based overflow

Published Oct 9, 2025 CVSS 4.0 · 8.7 High EPSS < 1% KEV · Not listed
Description
A vulnerability was determined in Tenda AC7 15.03.06.44. The impacted element is an unknown function of the file /goform/fast_setting_pppoe_set. Executing a manipulation of the argument Password can lead to stack-based buffer overflow. The attack may be launched remotely. The exploit has been publicly disclosed and may be utilized.

Remediation

No solution or workaround provided in the CVE record

Tracking

Sign in to view the affected projects.

Advisories

No advisories available
History
Type Values Removed Values Added
Description A vulnerability was determined in Tenda AC7 15.03.06.44. The impacted element is an unknown function of the file /goform/fast_setting_pppoe_set. Executing manipulation of the argument Password can lead to stack-based buffer overflow. The attack may be launched remotely. The exploit has been publicly disclosed and may be utilized. A vulnerability was determined in Tenda AC7 15.03.06.44. The impacted element is an unknown function of the file /goform/fast_setting_pppoe_set. Executing a manipulation of the argument Password can lead to stack-based buffer overflow. The attack may be launched remotely. The exploit has been publicly disclosed and may be utilized.
CPEs cpe:2.3:o:tenda:ac7_firmware:*:*:*:*:*:*:*:*
Type Values Removed Values Added
Metrics ssvc

{'options': {'Automatable': 'no', 'Exploitation': 'poc', 'Technical Impact': 'total'}, 'version': '2.0.3'}

Type Values Removed Values Added
First Time appeared Tenda ac7 Firmware
CPEs cpe:2.3:h:tenda:ac7:1.0:*:*:*:*:*:*:*
cpe:2.3:o:tenda:ac7_firmware:15.03.06.44:*:*:*:*:*:*:*
Vendors & Products Tenda ac7 Firmware
Type Values Removed Values Added
First Time appeared Tenda
Tenda ac7
Vendors & Products Tenda
Tenda ac7
Type Values Removed Values Added
Description A vulnerability was determined in Tenda AC7 15.03.06.44. The impacted element is an unknown function of the file /goform/fast_setting_pppoe_set. Executing manipulation of the argument Password can lead to stack-based buffer overflow. The attack may be launched remotely. The exploit has been publicly disclosed and may be utilized.
Title Tenda AC7 fast_setting_pppoe_set stack-based overflow
Weaknesses CWE-119
CWE-121
References
Metrics cvssV2_0

{'score': 9, 'vector': 'AV:N/AC:L/Au:S/C:C/I:C/A:C/E:POC/RL:ND/RC:UR'}

cvssV3_0

{'score': 8.8, 'vector': 'CVSS:3.0/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H/E:P/RL:X/RC:R'}

cvssV3_1

{'score': 8.8, 'vector': 'CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H/E:P/RL:X/RC:R'}

cvssV4_0

{'score': 8.7, 'vector': 'CVSS:4.0/AV:N/AC:L/AT:N/PR:L/UI:N/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N/E:P'}

Weaknesses

Sources

Status
PUBLISHED
Assigner
VulDB
Published
Updated
Feb 24, 2026, 6:55 AM
Reserved
Oct 8, 2025, 7:05 PM
Status
Modified
Published
Oct 9, 2025, 3:15 AM
Modified
Oct 8, 2026, 1:10 PM