CVE-2024-8957

PTZOptics NDI and SDI Cameras Command Injection via NTP Address Configuration

Published Sep 17, 2024 CVSS 3.1 · 7.2 High EPSS 79.8% KEV · Listed
Description
PTZOptics PT30X-SDI/NDI-xx before firmware 6.3.40 is vulnerable to an OS command injection issue. The camera does not sufficiently validate the ntp_addr configuration value which may lead to arbitrary command execution when ntp_client is started. When chained with CVE-2024-8956, a remote and unauthenticated attacker can execute arbitrary OS commands on affected devices.

Remediation

No solution or workaround provided in the CVE record

Tracking

Sign in to view the affected projects.

Advisories

No advisories available
History
Type Values Removed Values Added
CPEs cpe:2.3:h:ptzoptics:pt30x-ndi-xx-g2:*:*:*:*:*:*:*:*
cpe:2.3:h:ptzoptics:pt30x-sdi:*:*:*:*:*:*:*:*
Type Values Removed Values Added
Metrics kev

{'dateAdded': '2024-11-04'}

Type Values Removed Values Added
Metrics ssvc

{'options': {'Automatable': 'no', 'Exploitation': 'none', 'Technical Impact': 'total'}, 'version': '2.0.3'}

ssvc

{'options': {'Automatable': 'no', 'Exploitation': 'active', 'Technical Impact': 'total'}, 'version': '2.0.3'}

Type Values Removed Values Added
First Time appeared Ptzoptics pt30x-ndi-xx-g2
Ptzoptics pt30x-ndi-xx-g2 Firmware
Ptzoptics pt30x-sdi
CPEs cpe:2.3:h:ptzoptics:pt30x-ndi-xx-g2:-:*:*:*:*:*:*:*
cpe:2.3:h:ptzoptics:pt30x-sdi:-:*:*:*:*:*:*:*
cpe:2.3:o:ptzoptics:pt30x-ndi-xx-g2_firmware:*:*:*:*:*:*:*:*
Vendors & Products Ptzoptics pt30x-ndi-xx-g2
Ptzoptics pt30x-ndi-xx-g2 Firmware
Ptzoptics pt30x-sdi
Type Values Removed Values Added
First Time appeared Ptzoptics
Ptzoptics pt30x-ndi Firmware
Ptzoptics pt30x-sdi Firmware
CPEs cpe:2.3:o:ptzoptics:pt30x-ndi_firmware:*:*:*:*:*:*:*:*
cpe:2.3:o:ptzoptics:pt30x-sdi_firmware:*:*:*:*:*:*:*:*
Vendors & Products Ptzoptics
Ptzoptics pt30x-ndi Firmware
Ptzoptics pt30x-sdi Firmware
Metrics ssvc

{'options': {'Automatable': 'no', 'Exploitation': 'none', 'Technical Impact': 'total'}, 'version': '2.0.3'}

Type Values Removed Values Added
Description PTZOptics PT30X-SDI/NDI-xx before firmware 6.3.40 is vulnerable to an OS command injection issue. The camera does not sufficiently validate the ntp_addr configuration value which may lead to arbitrary command execution when ntp_client is started. When chained with CVE-2024-8956, a remote and unauthenticated attacker can execute arbitrary OS commands on affected devices.
Title PTZOptics NDI and SDI Cameras Command Injection via NTP Address Configuration
Weaknesses CWE-78
References
Metrics cvssV3_1

{'score': 7.2, 'vector': 'CVSS:3.1/AV:N/AC:L/PR:H/UI:N/S:U/C:H/I:H/A:H'}

Weaknesses

Sources

Status
PUBLISHED
Assigner
VulnCheck
Published
Updated
Dec 27, 2025, 4:47 PM
Reserved
Sep 17, 2024, 7:08 PM
Status
Analyzed
Published
Sep 17, 2024, 9:15 PM
Modified
Jun 17, 2026, 8:23 AM