{"affected": [{"affectedData": [{"defaultStatus": "unknown", "product": "SIPROTEC 5 6MD84 (CP300)", "vendor": "Siemens", "versions": [{"lessThan": "V9.80", "status": "affected", "version": "0", "versionType": "custom"}]}, {"defaultStatus": "unknown", "product": "SIPROTEC 5 6MD85 (CP300)", "vendor": "Siemens", "versions": [{"lessThan": "V9.80", "status": "affected", "version": "V7.80", "versionType": "custom"}]}, {"defaultStatus": "unknown", "product": "SIPROTEC 5 6MD86 (CP300)", "vendor": "Siemens", "versions": [{"lessThan": "V9.80", "status": "affected", "version": "V7.80", "versionType": "custom"}]}, {"defaultStatus": "unknown", "product": "SIPROTEC 5 6MD89 (CP300)", "vendor": "Siemens", "versions": [{"lessThan": "V9.68", "status": "affected", "version": "V7.80", "versionType": "custom"}]}, {"defaultStatus": "unknown", "product": "SIPROTEC 5 6MU85 (CP300)", "vendor": "Siemens", "versions": [{"lessThan": "V9.80", "status": "affected", "version": "V7.80", "versionType": "custom"}]}, {"defaultStatus": "unknown", "product": "SIPROTEC 5 7KE85 (CP300)", "vendor": "Siemens", "versions": [{"lessThan": "V9.80", "status": "affected", "version": "V7.80", "versionType": "custom"}]}, {"defaultStatus": "unknown", "product": "SIPROTEC 5 7SA82 (CP100)", "vendor": "Siemens", "versions": [{"lessThan": "V8.90", "status": "affected", "version": "V7.80", "versionType": "custom"}]}, {"defaultStatus": "unknown", "product": "SIPROTEC 5 7SA82 (CP150)", "vendor": "Siemens", "versions": [{"lessThan": "V9.80", "status": "affected", "version": "0", "versionType": "custom"}]}, {"defaultStatus": "unknown", "product": "SIPROTEC 5 7SA86 (CP300)", "vendor": "Siemens", "versions": [{"lessThan": "V9.80", "status": "affected", "version": "V7.80", "versionType": "custom"}]}, {"defaultStatus": "unknown", "product": "SIPROTEC 5 7SA87 (CP300)", "vendor": "Siemens", "versions": [{"lessThan": "V9.80", "status": "affected", "version": "V7.80", "versionType": "custom"}]}, {"defaultStatus": "unknown", "product": "SIPROTEC 5 7SD82 (CP100)", "vendor": "Siemens", "versions": [{"lessThan": "V8.90", "status": "affected", "version": "V7.80", "versionType": "custom"}]}, {"defaultStatus": "unknown", "product": "SIPROTEC 5 7SD82 (CP150)", "vendor": "Siemens", "versions": [{"lessThan": "V9.80", "status": "affected", "version": "0", "versionType": "custom"}]}, {"defaultStatus": "unknown", "product": "SIPROTEC 5 7SD86 (CP300)", "vendor": "Siemens", "versions": [{"lessThan": "V9.80", "status": "affected", "version": "V7.80", "versionType": "custom"}]}, {"defaultStatus": "unknown", "product": "SIPROTEC 5 7SD87 (CP300)", "vendor": "Siemens", "versions": [{"lessThan": "V9.80", "status": "affected", "version": "V7.80", "versionType": "custom"}]}, {"defaultStatus": "unknown", "product": "SIPROTEC 5 7SJ81 (CP100)", "vendor": "Siemens", "versions": [{"lessThan": "V8.90", "status": "affected", "version": "V7.80", "versionType": "custom"}]}, {"defaultStatus": "unknown", "product": "SIPROTEC 5 7SJ81 (CP150)", "vendor": "Siemens", "versions": [{"lessThan": "V9.80", "status": "affected", "version": "0", "versionType": "custom"}]}, {"defaultStatus": "unknown", "product": "SIPROTEC 5 7SJ82 (CP100)", "vendor": "Siemens", "versions": [{"lessThan": "V8.90", "status": "affected", "version": "V7.80", "versionType": "custom"}]}, {"defaultStatus": "unknown", "product": "SIPROTEC 5 7SJ82 (CP150)", "vendor": "Siemens", "versions": [{"lessThan": "V9.80", "status": "affected", "version": "0", "versionType": "custom"}]}, {"defaultStatus": "unknown", "product": "SIPROTEC 5 7SJ85 (CP300)", "vendor": "Siemens", "versions": [{"lessThan": "V9.80", "status": "affected", "version": "V7.80", "versionType": "custom"}]}, {"defaultStatus": "unknown", "product": "SIPROTEC 5 7SJ86 (CP300)", "vendor": "Siemens", "versions": [{"lessThan": "V9.80", "status": "affected", "version": "V7.80", "versionType": "custom"}]}, {"defaultStatus": "unknown", "product": "SIPROTEC 5 7SK82 (CP100)", "vendor": "Siemens", "versions": [{"lessThan": "V8.90", "status": "affected", "version": "V7.80", "versionType": "custom"}]}, {"defaultStatus": "unknown", "product": "SIPROTEC 5 7SK82 (CP150)", "vendor": "Siemens", "versions": [{"lessThan": "V9.80", "status": "affected", "version": "0", "versionType": "custom"}]}, {"defaultStatus": "unknown", "product": "SIPROTEC 5 7SK85 (CP300)", "vendor": "Siemens", "versions": [{"lessThan": "V9.80", "status": "affected", "version": "V7.80", "versionType": "custom"}]}, {"defaultStatus": "unknown", "product": "SIPROTEC 5 7SL82 (CP100)", "vendor": "Siemens", "versions": [{"lessThan": "V8.90", "status": "affected", "version": "V7.80", "versionType": "custom"}]}, {"defaultStatus": "unknown", "product": "SIPROTEC 5 7SL82 (CP150)", "vendor": "Siemens", "versions": [{"lessThan": "V9.80", "status": "affected", "version": "0", "versionType": "custom"}]}, {"defaultStatus": "unknown", "product": "SIPROTEC 5 7SL86 (CP300)", "vendor": "Siemens", "versions": [{"lessThan": "V9.80", "status": "affected", "version": "V7.80", "versionType": "custom"}]}, {"defaultStatus": "unknown", "product": "SIPROTEC 5 7SL87 (CP300)", "vendor": "Siemens", "versions": [{"lessThan": "V9.80", "status": "affected", "version": "V7.80", "versionType": "custom"}]}, {"defaultStatus": "unknown", "product": "SIPROTEC 5 7SS85 (CP300)", "vendor": "Siemens", "versions": [{"lessThan": "V9.80", "status": "affected", "version": "V7.80", "versionType": "custom"}]}, {"defaultStatus": "unknown", "product": "SIPROTEC 5 7ST85 (CP300)", "vendor": "Siemens", "versions": [{"lessThan": "V9.68", "status": "affected", "version": "0", "versionType": "custom"}]}, {"defaultStatus": "unknown", "product": "SIPROTEC 5 7ST86 (CP300)", "vendor": "Siemens", "versions": [{"lessThan": "V9.80", "status": "affected", "version": "0", "versionType": "custom"}]}, {"defaultStatus": "unknown", "product": "SIPROTEC 5 7SX82 (CP150)", "vendor": "Siemens", "versions": [{"lessThan": "V9.80", "status": "affected", "version": "0", "versionType": "custom"}]}, {"defaultStatus": "unknown", "product": "SIPROTEC 5 7SX85 (CP300)", "vendor": "Siemens", "versions": [{"lessThan": "V9.80", "status": "affected", "version": "0", "versionType": "custom"}]}, {"defaultStatus": "unknown", "product": "SIPROTEC 5 7SY82 (CP150)", "vendor": "Siemens", "versions": [{"lessThan": "V9.80", "status": "affected", "version": "0", "versionType": "custom"}]}, {"defaultStatus": "unknown", "product": "SIPROTEC 5 7UM85 (CP300)", "vendor": "Siemens", "versions": [{"lessThan": "V9.80", "status": "affected", "version": "V7.80", "versionType": "custom"}]}, {"defaultStatus": "unknown", "product": "SIPROTEC 5 7UT82 (CP100)", "vendor": "Siemens", "versions": [{"lessThan": "V8.90", "status": "affected", "version": "V7.80", "versionType": "custom"}]}, {"defaultStatus": "unknown", "product": "SIPROTEC 5 7UT82 (CP150)", "vendor": "Siemens", "versions": [{"lessThan": "V9.80", "status": "affected", "version": "0", "versionType": "custom"}]}, {"defaultStatus": "unknown", "product": "SIPROTEC 5 7UT85 (CP300)", "vendor": "Siemens", "versions": [{"lessThan": "V9.80", "status": "affected", "version": "V7.80", "versionType": "custom"}]}, {"defaultStatus": "unknown", "product": "SIPROTEC 5 7UT86 (CP300)", "vendor": "Siemens", "versions": [{"lessThan": "V9.80", "status": "affected", "version": "V7.80", "versionType": "custom"}]}, {"defaultStatus": "unknown", "product": "SIPROTEC 5 7UT87 (CP300)", "vendor": "Siemens", "versions": [{"lessThan": "V9.80", "status": "affected", "version": "V7.80", "versionType": "custom"}]}, {"defaultStatus": "unknown", "product": "SIPROTEC 5 7VE85 (CP300)", "vendor": "Siemens", "versions": [{"lessThan": "V9.80", "status": "affected", "version": "V7.80", "versionType": "custom"}]}, {"defaultStatus": "unknown", "product": "SIPROTEC 5 7VK87 (CP300)", "vendor": "Siemens", "versions": [{"lessThan": "V9.80", "status": "affected", "version": "V7.80", "versionType": "custom"}]}, {"defaultStatus": "unknown", "product": "SIPROTEC 5 7VU85 (CP300)", "vendor": "Siemens", "versions": [{"lessThan": "V9.80", "status": "affected", "version": "0", "versionType": "custom"}]}, {"defaultStatus": "unknown", "product": "SIPROTEC 5 Compact 7SX800 (CP050)", "vendor": "Siemens", "versions": [{"lessThan": "V9.80", "status": "affected", "version": "0", "versionType": "custom"}]}], "source": "productcert@siemens.com"}], "cveTags": [], "descriptions": [{"lang": "en", "value": "A vulnerability has been identified in SIPROTEC 5 6MD84 (CP300) (All versions < V9.80), SIPROTEC 5 6MD85 (CP300) (All versions >= V7.80 < V9.80), SIPROTEC 5 6MD86 (CP300) (All versions >= V7.80 < V9.80), SIPROTEC 5 6MD89 (CP300) (All versions >= V7.80 < V9.68), SIPROTEC 5 6MU85 (CP300) (All versions >= V7.80 < V9.80), SIPROTEC 5 7KE85 (CP300) (All versions >= V7.80 < V9.80), SIPROTEC 5 7SA82 (CP100) (All versions >= V7.80 < V8.90), SIPROTEC 5 7SA82 (CP150) (All versions < V9.80), SIPROTEC 5 7SA86 (CP300) (All versions >= V7.80 < V9.80), SIPROTEC 5 7SA87 (CP300) (All versions >= V7.80 < V9.80), SIPROTEC 5 7SD82 (CP100) (All versions >= V7.80 < V8.90), SIPROTEC 5 7SD82 (CP150) (All versions < V9.80), SIPROTEC 5 7SD86 (CP300) (All versions >= V7.80 < V9.80), SIPROTEC 5 7SD87 (CP300) (All versions >= V7.80 < V9.80), SIPROTEC 5 7SJ81 (CP100) (All versions >= V7.80 < V8.90), SIPROTEC 5 7SJ81 (CP150) (All versions < V9.80), SIPROTEC 5 7SJ82 (CP100) (All versions >= V7.80 < V8.90), SIPROTEC 5 7SJ82 (CP150) (All versions < V9.80), SIPROTEC 5 7SJ85 (CP300) (All versions >= V7.80 < V9.80), SIPROTEC 5 7SJ86 (CP300) (All versions >= V7.80 < V9.80), SIPROTEC 5 7SK82 (CP100) (All versions >= V7.80 < V8.90), SIPROTEC 5 7SK82 (CP150) (All versions < V9.80), SIPROTEC 5 7SK85 (CP300) (All versions >= V7.80 < V9.80), SIPROTEC 5 7SL82 (CP100) (All versions >= V7.80 < V8.90), SIPROTEC 5 7SL82 (CP150) (All versions < V9.80), SIPROTEC 5 7SL86 (CP300) (All versions >= V7.80 < V9.80), SIPROTEC 5 7SL87 (CP300) (All versions >= V7.80 < V9.80), SIPROTEC 5 7SS85 (CP300) (All versions >= V7.80 < V9.80), SIPROTEC 5 7ST85 (CP300) (All versions < V9.68), SIPROTEC 5 7ST86 (CP300) (All versions < V9.80), SIPROTEC 5 7SX82 (CP150) (All versions < V9.80), SIPROTEC 5 7SX85 (CP300) (All versions < V9.80), SIPROTEC 5 7SY82 (CP150) (All versions < V9.80), SIPROTEC 5 7UM85 (CP300) (All versions >= V7.80 < V9.80), SIPROTEC 5 7UT82 (CP100) (All versions >= V7.80 < V8.90), SIPROTEC 5 7UT82 (CP150) (All versions < V9.80), SIPROTEC 5 7UT85 (CP300) (All versions >= V7.80 < V9.80), SIPROTEC 5 7UT86 (CP300) (All versions >= V7.80 < V9.80), SIPROTEC 5 7UT87 (CP300) (All versions >= V7.80 < V9.80), SIPROTEC 5 7VE85 (CP300) (All versions >= V7.80 < V9.80), SIPROTEC 5 7VK87 (CP300) (All versions >= V7.80 < V9.80), SIPROTEC 5 7VU85 (CP300) (All versions < V9.80), SIPROTEC 5 Compact 7SX800 (CP050) (All versions < V9.80). Affected devices do not properly limit the path accessible via their webserver. This could allow an authenticated remote attacker to read arbitrary files from the filesystem of affected devices."}, {"lang": "es", "value": "Se ha identificado una vulnerabilidad en SIPROTEC 5 6MD84 (CP300) (Todas las versiones < V9.80), SIPROTEC 5 6MD85 (CP300) (Todas las versiones >= V7.80 < V9.80), SIPROTEC 5 6MD86 (CP300) (Todas las versiones >= V7.80 < V9.80), SIPROTEC 5 6MD89 (CP300) (Todas las versiones >= V7.80), SIPROTEC 5 6MU85 (CP300) (Todas las versiones >= V7.80 < V9.80), SIPROTEC 5 7KE85 (CP300) (Todas las versiones >= V7.80 < V9.80), SIPROTEC 5 7SA82 (CP100) (Todas las versiones >= V7.80), SIPROTEC 5 7SA82 (CP150) (Todas las versiones < V9.80), SIPROTEC 5 7SA86 (CP300) (Todas las versiones >= V7.80 < V9.80), SIPROTEC 5 7SA87 (CP300) (Todas las versiones >= V7.80 < V9.80), SIPROTEC 5 7SD82 (CP100) (Todas las versiones >= V7.80), SIPROTEC 5 7SD82 (CP150) (Todas las versiones < V9.80), SIPROTEC 5 7SD86 (CP300) (Todas las versiones >= V7.80 < V9.80), SIPROTEC 5 7SD87 (CP300) (Todas las versiones >= V7.80 < V9.80), SIPROTEC 5 7SJ81 (CP100) (Todas las versiones >= V7.80), SIPROTEC 5 7SJ81 (CP150) (Todas las versiones < V9.80), SIPROTEC 5 7SJ82 (CP100) (Todas las versiones >= V7.80), SIPROTEC 5 7SJ82 (CP150) (Todas las versiones < V9.80), SIPROTEC 5 7SJ85 (CP300) (Todas las versiones >= V7.80 < V9.80), SIPROTEC 5 7SJ86 (CP300) (Todas las versiones >= V7.80 < V9.80), SIPROTEC 5 7SK82 (CP100) (Todas las versiones >= V7.80), SIPROTEC 5 7SK82 (CP150) (Todas las versiones < V9.80), SIPROTEC 5 7SK85 (CP300) (Todas las versiones >= V7.80 < V9.80), SIPROTEC 5 7SL82 (CP100) (Todas las versiones >= V7.80), SIPROTEC 5 7SL82 (CP150) (Todas las versiones < V9.80), SIPROTEC 5 7SL86 (CP300) (Todas las versiones >= V7.80 < V9.80), SIPROTEC 5 7SL87 (CP300) (Todas las versiones >= V7.80 < V9.80), SIPROTEC 5 7SS85 (CP300) (Todas las versiones >= V7.80 < V9.80), SIPROTEC 5 7ST85 (CP300) (Todas las versiones), SIPROTEC 5 7ST86 (CP300) (Todas las versiones < V9.80), SIPROTEC 5 7SX82 (CP150) (Todas las versiones < V9.80), SIPROTEC 5 7SX85 (CP300) (Todas las versiones < V9.80), SIPROTEC 5 7SY82 (CP150) (Todas las versiones < V9.80), SIPROTEC 5 7UM85 (CP300) (Todas las versiones >= V7.80 < V9.80), SIPROTEC 5 7UT82 (CP100) (Todas las versiones >= V7.80), SIPROTEC 5 7UT82 (CP150) (Todas las versiones < V9.80), SIPROTEC 5 7UT85 (CP300) (Todas las versiones >= V7.80 < V9.80), SIPROTEC 5 7UT86 (CP300) (Todas las versiones >= V7.80 < V9.80), SIPROTEC 5 7UT87 (CP300) (Todas las versiones >= V7.80 < V9.80), SIPROTEC 5 7VE85 (CP300) (Todas las versiones >= V7.80 < V9.80), SIPROTEC 5 7VK87 (CP300) (Todas las versiones >= V7.80 < V9.80), SIPROTEC 5 7VU85 (CP300) (todas las versiones anteriores a V9.80), SIPROTEC 5 Compact 7SX800 (CP050) (todas las versiones anteriores a V9.80). Los dispositivos afectados no limitan adecuadamente la ruta a la que se puede acceder a trav\u00e9s de su servidor web. Esto podr\u00eda permitir que un atacante remoto autenticado lea archivos arbitrarios del sistema de archivos de los dispositivos afectados."}], "id": "CVE-2024-53649", "lastModified": "2026-06-17T08:09:03.997", "metrics": {"cvssMetricV31": [{"cvssData": {"attackComplexity": "LOW", "attackVector": "NETWORK", "availabilityImpact": "NONE", "baseScore": 6.5, "baseSeverity": "MEDIUM", "confidentialityImpact": "HIGH", "integrityImpact": "NONE", "privilegesRequired": "LOW", "scope": "UNCHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:N/A:N", "version": "3.1"}, "exploitabilityScore": 2.8, "impactScore": 3.6, "source": "productcert@siemens.com", "type": "Secondary"}], "cvssMetricV40": [{"cvssData": {"Automatable": "NOT_DEFINED", "Recovery": "NOT_DEFINED", "Safety": "NOT_DEFINED", "attackComplexity": "LOW", "attackRequirements": "NONE", "attackVector": "NETWORK", "availabilityRequirement": "NOT_DEFINED", "baseScore": 7.1, "baseSeverity": "HIGH", "confidentialityRequirement": "NOT_DEFINED", "exploitMaturity": "NOT_DEFINED", "integrityRequirement": "NOT_DEFINED", "modifiedAttackComplexity": "NOT_DEFINED", "modifiedAttackRequirements": "NOT_DEFINED", "modifiedAttackVector": "NOT_DEFINED", "modifiedPrivilegesRequired": "NOT_DEFINED", "modifiedSubAvailabilityImpact": "NOT_DEFINED", "modifiedSubConfidentialityImpact": "NOT_DEFINED", "modifiedSubIntegrityImpact": "NOT_DEFINED", "modifiedUserInteraction": "NOT_DEFINED", "modifiedVulnAvailabilityImpact": "NOT_DEFINED", "modifiedVulnConfidentialityImpact": "NOT_DEFINED", "modifiedVulnIntegrityImpact": "NOT_DEFINED", "privilegesRequired": "LOW", "providerUrgency": "NOT_DEFINED", "subAvailabilityImpact": "NONE", "subConfidentialityImpact": "NONE", "subIntegrityImpact": "NONE", "userInteraction": "NONE", "valueDensity": "NOT_DEFINED", "vectorString": "CVSS:4.0/AV:N/AC:L/AT:N/PR:L/UI:N/VC:H/VI:N/VA:N/SC:N/SI:N/SA:N/E:X/CR:X/IR:X/AR:X/MAV:X/MAC:X/MAT:X/MPR:X/MUI:X/MVC:X/MVI:X/MVA:X/MSC:X/MSI:X/MSA:X/S:X/AU:X/R:X/V:X/RE:X/U:X", "version": "4.0", "vulnAvailabilityImpact": "NONE", "vulnConfidentialityImpact": "HIGH", "vulnIntegrityImpact": "NONE", "vulnerabilityResponseEffort": "NOT_DEFINED"}, "source": "productcert@siemens.com", "type": "Secondary"}], "ssvcV203": [{"source": "134c704f-9b21-4f2e-91b3-4a467353bcc0", "ssvcData": {"id": "CVE-2024-53649", "options": [{"exploitation": "none"}, {"automatable": "no"}, {"technicalImpact": "partial"}], "role": "CISA Coordinator", "timestamp": "2025-01-14T14:31:48.612161Z", "version": "2.0.3"}}]}, "published": "2025-01-14T11:15:16.820", "references": [{"source": "productcert@siemens.com", "url": "https://cert-portal.siemens.com/productcert/html/ssa-194557.html"}], "sourceIdentifier": "productcert@siemens.com", "vulnStatus": "Deferred", "weaknesses": [{"description": [{"lang": "en", "value": "CWE-552"}], "source": "productcert@siemens.com", "type": "Secondary"}]}