{"affected": [{"affectedData": [{"defaultStatus": "unknown", "product": "Teamcenter Visualization V14.2", "vendor": "Siemens", "versions": [{"lessThan": "V14.2.0.14", "status": "affected", "version": "0", "versionType": "custom"}]}, {"defaultStatus": "unknown", "product": "Teamcenter Visualization V14.3", "vendor": "Siemens", "versions": [{"lessThan": "V14.3.0.12", "status": "affected", "version": "0", "versionType": "custom"}]}, {"defaultStatus": "unknown", "product": "Teamcenter Visualization V2312", "vendor": "Siemens", "versions": [{"lessThan": "V2312.0008", "status": "affected", "version": "0", "versionType": "custom"}]}, {"defaultStatus": "unknown", "product": "Teamcenter Visualization V2406", "vendor": "Siemens", "versions": [{"lessThan": "V2406.0005", "status": "affected", "version": "0", "versionType": "custom"}]}, {"defaultStatus": "unknown", "product": "Tecnomatix Plant Simulation V2302", "vendor": "Siemens", "versions": [{"lessThan": "V2302.0018", "status": "affected", "version": "0", "versionType": "custom"}]}, {"defaultStatus": "unknown", "product": "Tecnomatix Plant Simulation V2404", "vendor": "Siemens", "versions": [{"lessThan": "V2404.0007", "status": "affected", "version": "0", "versionType": "custom"}]}], "source": "productcert@siemens.com"}, {"affectedData": [{"cpes": ["cpe:2.3:a:siemens:tecnomatix_plant_simulation:-:*:*:*:*:*:*:*"], "defaultStatus": "unknown", "product": "tecnomatix_plant_simulation", "vendor": "siemens", "versions": [{"lessThan": "V2302.0018", "status": "affected", "version": "0", "versionType": "custom"}, {"lessThan": "V2404.0007", "status": "affected", "version": "0", "versionType": "custom"}]}], "source": "134c704f-9b21-4f2e-91b3-4a467353bcc0"}], "configurations": [{"nodes": [{"cpeMatch": [{"criteria": "cpe:2.3:a:siemens:tecnomatix_plant_simulation:*:*:*:*:*:*:*:*", "matchCriteriaId": "9CB96290-C77A-4C14-9E5B-4F99DB187B31", "versionEndExcluding": "2302.0018", "vulnerable": true}, {"criteria": "cpe:2.3:a:siemens:tecnomatix_plant_simulation:*:*:*:*:*:*:*:*", "matchCriteriaId": "49153630-5A8F-429E-A5AA-8D0C1737D166", "versionEndExcluding": "2404.0007", "versionStartIncluding": "2404.0", "vulnerable": true}], "negate": false, "operator": "OR"}]}], "cveTags": [], "descriptions": [{"lang": "en", "value": "A vulnerability has been identified in Teamcenter Visualization V14.2 (All versions < V14.2.0.14), Teamcenter Visualization V14.3 (All versions < V14.3.0.12), Teamcenter Visualization V2312 (All versions < V2312.0008), Teamcenter Visualization V2406 (All versions < V2406.0005), Tecnomatix Plant Simulation V2302 (All versions < V2302.0018), Tecnomatix Plant Simulation V2404 (All versions < V2404.0007). The affected applications contain a use-after-free vulnerability that could be triggered while parsing specially crafted WRL files.\r\nAn attacker could leverage this vulnerability to execute code in the context of the current process. (ZDI-CAN-24244)"}, {"lang": "es", "value": "Se ha identificado una vulnerabilidad en Tecnomatix Plant Simulation V2302 (todas las versiones anteriores a V2302.0018) y Tecnomatix Plant Simulation V2404 (todas las versiones anteriores a V2404.0007). Las aplicaciones afectadas contienen una vulnerabilidad de use-after-free que podr\u00eda activarse al analizar archivos WRL especialmente manipulados. Un atacante podr\u00eda aprovechar esta vulnerabilidad para ejecutar c\u00f3digo en el contexto del proceso actual. (ZDI-CAN-24244)"}], "id": "CVE-2024-52568", "lastModified": "2026-06-17T08:07:28.240", "metrics": {"cvssMetricV31": [{"cvssData": {"attackComplexity": "LOW", "attackVector": "LOCAL", "availabilityImpact": "HIGH", "baseScore": 7.8, "baseSeverity": "HIGH", "confidentialityImpact": "HIGH", "integrityImpact": "HIGH", "privilegesRequired": "NONE", "scope": "UNCHANGED", "userInteraction": "REQUIRED", "vectorString": "CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H", "version": "3.1"}, "exploitabilityScore": 1.8, "impactScore": 5.9, "source": "productcert@siemens.com", "type": "Secondary"}], "cvssMetricV40": [{"cvssData": {"Automatable": "NOT_DEFINED", "Recovery": "NOT_DEFINED", "Safety": "NOT_DEFINED", "attackComplexity": "HIGH", "attackRequirements": "NONE", "attackVector": "LOCAL", "availabilityRequirement": "NOT_DEFINED", "baseScore": 7.3, "baseSeverity": "HIGH", "confidentialityRequirement": "NOT_DEFINED", "exploitMaturity": "NOT_DEFINED", "integrityRequirement": "NOT_DEFINED", "modifiedAttackComplexity": "NOT_DEFINED", "modifiedAttackRequirements": "NOT_DEFINED", "modifiedAttackVector": "NOT_DEFINED", "modifiedPrivilegesRequired": "NOT_DEFINED", "modifiedSubAvailabilityImpact": "NOT_DEFINED", "modifiedSubConfidentialityImpact": "NOT_DEFINED", "modifiedSubIntegrityImpact": "NOT_DEFINED", "modifiedUserInteraction": "NOT_DEFINED", "modifiedVulnAvailabilityImpact": "NOT_DEFINED", "modifiedVulnConfidentialityImpact": "NOT_DEFINED", "modifiedVulnIntegrityImpact": "NOT_DEFINED", "privilegesRequired": "NONE", "providerUrgency": "NOT_DEFINED", "subAvailabilityImpact": "NONE", "subConfidentialityImpact": "NONE", "subIntegrityImpact": "NONE", "userInteraction": "PASSIVE", "valueDensity": "NOT_DEFINED", "vectorString": "CVSS:4.0/AV:L/AC:H/AT:N/PR:N/UI:P/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N/E:X/CR:X/IR:X/AR:X/MAV:X/MAC:X/MAT:X/MPR:X/MUI:X/MVC:X/MVI:X/MVA:X/MSC:X/MSI:X/MSA:X/S:X/AU:X/R:X/V:X/RE:X/U:X", "version": "4.0", "vulnAvailabilityImpact": "HIGH", "vulnConfidentialityImpact": "HIGH", "vulnIntegrityImpact": "HIGH", "vulnerabilityResponseEffort": "NOT_DEFINED"}, "source": "productcert@siemens.com", "type": "Secondary"}], "ssvcV203": [{"source": "134c704f-9b21-4f2e-91b3-4a467353bcc0", "ssvcData": {"id": "CVE-2024-52568", "options": [{"exploitation": "none"}, {"automatable": "no"}, {"technicalImpact": "total"}], "role": "CISA Coordinator", "timestamp": "2024-11-18T19:00:13.859137Z", "version": "2.0.3"}}]}, "published": "2024-11-18T16:15:27.773", "references": [{"source": "productcert@siemens.com", "url": "https://cert-portal.siemens.com/productcert/html/ssa-645131.html"}, {"source": "productcert@siemens.com", "tags": ["Vendor Advisory"], "url": "https://cert-portal.siemens.com/productcert/html/ssa-824503.html"}], "sourceIdentifier": "productcert@siemens.com", "vulnStatus": "Modified", "weaknesses": [{"description": [{"lang": "en", "value": "CWE-416"}], "source": "productcert@siemens.com", "type": "Secondary"}]}